  "metadata": {
    "title": "Benchmark Matrix: Building Envelope Thermal Transmission, Fenestration SHGC, and Infiltration Sizing per ACCA Manual J",
    "identifier": "FIG-04",
    "total_records": 540,
    "generated_at": "2026-09-13T13:58:59.746Z",
    "governing_standards": [
      "ACCA Manual J (8th Edition)",
      "ASHRAE Handbook of Fundamentals",
      "IECC 2021/2024"
    ],
    "canonical_url": "https://hvaclogic.org/calculators/btu-calculator",
    "license": "CC BY 4.0"
  },
  "records": [
    {
      "scenario_id": "ENV-0001",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 15860,
      "heating_infiltration_loss_btu_h": 3531,
      "total_peak_heating_load_btu_h": 19391,
      "summer_conduction_gain_btu_h": 10120,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 2017,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 22789,
      "total_cooling_latent_load_btu_h": 4895,
      "total_cooling_peak_load_btu_h": 27684,
      "calculated_cooling_tonnage": 2.31,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 29.9,
      "sensible_heat_ratio_shr": 0.823,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0002",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 24205,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 30457,
      "summer_conduction_gain_btu_h": 15336,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 3573,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 34310,
      "total_cooling_latent_load_btu_h": 8405,
      "total_cooling_peak_load_btu_h": 42715,
      "calculated_cooling_tonnage": 3.56,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 40.4,
      "sensible_heat_ratio_shr": 0.803,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0003",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 33460,
      "heating_infiltration_loss_btu_h": 9533,
      "total_peak_heating_load_btu_h": 42993,
      "summer_conduction_gain_btu_h": 21058,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 5448,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 47404,
      "total_cooling_latent_load_btu_h": 12596,
      "total_cooling_peak_load_btu_h": 60000,
      "calculated_cooling_tonnage": 5,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 44,
      "sensible_heat_ratio_shr": 0.79,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0004",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 15860,
      "heating_infiltration_loss_btu_h": 1455,
      "total_peak_heating_load_btu_h": 17315,
      "summer_conduction_gain_btu_h": 10120,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 832,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 21604,
      "total_cooling_latent_load_btu_h": 2370,
      "total_cooling_peak_load_btu_h": 23974,
      "calculated_cooling_tonnage": 2,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 50,
      "sensible_heat_ratio_shr": 0.901,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0005",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 24205,
      "heating_infiltration_loss_btu_h": 2574,
      "total_peak_heating_load_btu_h": 26779,
      "summer_conduction_gain_btu_h": 15336,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1471,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 32208,
      "total_cooling_latent_load_btu_h": 3931,
      "total_cooling_peak_load_btu_h": 36139,
      "calculated_cooling_tonnage": 3.01,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 66.1,
      "sensible_heat_ratio_shr": 0.891,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0006",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 33460,
      "heating_infiltration_loss_btu_h": 3924,
      "total_peak_heating_load_btu_h": 37384,
      "summer_conduction_gain_btu_h": 21058,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 2242,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 44198,
      "total_cooling_latent_load_btu_h": 5773,
      "total_cooling_peak_load_btu_h": 49971,
      "calculated_cooling_tonnage": 4.16,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 73.1,
      "sensible_heat_ratio_shr": 0.884,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0007",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 15860,
      "heating_infiltration_loss_btu_h": 499,
      "total_peak_heating_load_btu_h": 16359,
      "summer_conduction_gain_btu_h": 10120,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 285,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 21057,
      "total_cooling_latent_load_btu_h": 1207,
      "total_cooling_peak_load_btu_h": 22264,
      "calculated_cooling_tonnage": 1.86,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 61.3,
      "sensible_heat_ratio_shr": 0.946,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0008",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 24205,
      "heating_infiltration_loss_btu_h": 885,
      "total_peak_heating_load_btu_h": 25090,
      "summer_conduction_gain_btu_h": 15336,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 505,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 31242,
      "total_cooling_latent_load_btu_h": 1876,
      "total_cooling_peak_load_btu_h": 33118,
      "calculated_cooling_tonnage": 2.76,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 81.2,
      "sensible_heat_ratio_shr": 0.943,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0009",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 33460,
      "heating_infiltration_loss_btu_h": 1346,
      "total_peak_heating_load_btu_h": 34806,
      "summer_conduction_gain_btu_h": 21058,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 769,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 42725,
      "total_cooling_latent_load_btu_h": 2637,
      "total_cooling_peak_load_btu_h": 45362,
      "calculated_cooling_tonnage": 3.78,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 90.5,
      "sensible_heat_ratio_shr": 0.942,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0010",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 11670,
      "heating_infiltration_loss_btu_h": 3531,
      "total_peak_heating_load_btu_h": 15201,
      "summer_conduction_gain_btu_h": 7726,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 2017,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 18867,
      "total_cooling_latent_load_btu_h": 4895,
      "total_cooling_peak_load_btu_h": 23762,
      "calculated_cooling_tonnage": 1.98,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 51.5,
      "sensible_heat_ratio_shr": 0.794,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0011",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 17821,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 24073,
      "summer_conduction_gain_btu_h": 11688,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 3573,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 28332,
      "total_cooling_latent_load_btu_h": 8405,
      "total_cooling_peak_load_btu_h": 36737,
      "calculated_cooling_tonnage": 3.06,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 63.4,
      "sensible_heat_ratio_shr": 0.771,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0012",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 24483,
      "heating_infiltration_loss_btu_h": 9533,
      "total_peak_heating_load_btu_h": 34016,
      "summer_conduction_gain_btu_h": 15928,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 5448,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 38998,
      "total_cooling_latent_load_btu_h": 12596,
      "total_cooling_peak_load_btu_h": 51594,
      "calculated_cooling_tonnage": 4.3,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 67.4,
      "sensible_heat_ratio_shr": 0.756,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0013",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 11670,
      "heating_infiltration_loss_btu_h": 1455,
      "total_peak_heating_load_btu_h": 13125,
      "summer_conduction_gain_btu_h": 7726,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 832,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17682,
      "total_cooling_latent_load_btu_h": 2370,
      "total_cooling_peak_load_btu_h": 20052,
      "calculated_cooling_tonnage": 1.67,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 79.6,
      "sensible_heat_ratio_shr": 0.882,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0014",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 17821,
      "heating_infiltration_loss_btu_h": 2574,
      "total_peak_heating_load_btu_h": 20395,
      "summer_conduction_gain_btu_h": 11688,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1471,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 26230,
      "total_cooling_latent_load_btu_h": 3931,
      "total_cooling_peak_load_btu_h": 30161,
      "calculated_cooling_tonnage": 2.51,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 99.2,
      "sensible_heat_ratio_shr": 0.87,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0015",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 24483,
      "heating_infiltration_loss_btu_h": 3924,
      "total_peak_heating_load_btu_h": 28407,
      "summer_conduction_gain_btu_h": 15928,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 2242,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 35792,
      "total_cooling_latent_load_btu_h": 5773,
      "total_cooling_peak_load_btu_h": 41565,
      "calculated_cooling_tonnage": 3.46,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 108.1,
      "sensible_heat_ratio_shr": 0.861,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0016",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 11670,
      "heating_infiltration_loss_btu_h": 499,
      "total_peak_heating_load_btu_h": 12169,
      "summer_conduction_gain_btu_h": 7726,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 285,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17135,
      "total_cooling_latent_load_btu_h": 1207,
      "total_cooling_peak_load_btu_h": 18342,
      "calculated_cooling_tonnage": 1.53,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 96.1,
      "sensible_heat_ratio_shr": 0.934,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0017",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 17821,
      "heating_infiltration_loss_btu_h": 885,
      "total_peak_heating_load_btu_h": 18706,
      "summer_conduction_gain_btu_h": 11688,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 505,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 25264,
      "total_cooling_latent_load_btu_h": 1876,
      "total_cooling_peak_load_btu_h": 27140,
      "calculated_cooling_tonnage": 2.26,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 121.2,
      "sensible_heat_ratio_shr": 0.931,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0018",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 24483,
      "heating_infiltration_loss_btu_h": 1346,
      "total_peak_heating_load_btu_h": 25829,
      "summer_conduction_gain_btu_h": 15928,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 769,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 34319,
      "total_cooling_latent_load_btu_h": 2637,
      "total_cooling_peak_load_btu_h": 36956,
      "calculated_cooling_tonnage": 3.08,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 133.8,
      "sensible_heat_ratio_shr": 0.929,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0019",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 10200,
      "heating_infiltration_loss_btu_h": 3531,
      "total_peak_heating_load_btu_h": 13731,
      "summer_conduction_gain_btu_h": 6886,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 2017,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14314,
      "total_cooling_latent_load_btu_h": 4895,
      "total_cooling_peak_load_btu_h": 19209,
      "calculated_cooling_tonnage": 1.6,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 87.5,
      "sensible_heat_ratio_shr": 0.745,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0020",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 15581,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 21833,
      "summer_conduction_gain_btu_h": 10408,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 3573,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 21395,
      "total_cooling_latent_load_btu_h": 8405,
      "total_cooling_peak_load_btu_h": 29800,
      "calculated_cooling_tonnage": 2.48,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 101.6,
      "sensible_heat_ratio_shr": 0.718,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0021",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 21333,
      "heating_infiltration_loss_btu_h": 9533,
      "total_peak_heating_load_btu_h": 30866,
      "summer_conduction_gain_btu_h": 14128,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 5448,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 29242,
      "total_cooling_latent_load_btu_h": 12596,
      "total_cooling_peak_load_btu_h": 41838,
      "calculated_cooling_tonnage": 3.49,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 106.3,
      "sensible_heat_ratio_shr": 0.699,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0022",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 10200,
      "heating_infiltration_loss_btu_h": 1455,
      "total_peak_heating_load_btu_h": 11655,
      "summer_conduction_gain_btu_h": 6886,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 832,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13129,
      "total_cooling_latent_load_btu_h": 2370,
      "total_cooling_peak_load_btu_h": 15499,
      "calculated_cooling_tonnage": 1.29,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 132.6,
      "sensible_heat_ratio_shr": 0.847,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0023",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 15581,
      "heating_infiltration_loss_btu_h": 2574,
      "total_peak_heating_load_btu_h": 18155,
      "summer_conduction_gain_btu_h": 10408,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1471,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 19293,
      "total_cooling_latent_load_btu_h": 3931,
      "total_cooling_peak_load_btu_h": 23224,
      "calculated_cooling_tonnage": 1.94,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 157.7,
      "sensible_heat_ratio_shr": 0.831,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0024",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 21333,
      "heating_infiltration_loss_btu_h": 3924,
      "total_peak_heating_load_btu_h": 25257,
      "summer_conduction_gain_btu_h": 14128,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 2242,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 26036,
      "total_cooling_latent_load_btu_h": 5773,
      "total_cooling_peak_load_btu_h": 31809,
      "calculated_cooling_tonnage": 2.65,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 171.7,
      "sensible_heat_ratio_shr": 0.819,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0025",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 10200,
      "heating_infiltration_loss_btu_h": 499,
      "total_peak_heating_load_btu_h": 10699,
      "summer_conduction_gain_btu_h": 6886,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 285,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 12582,
      "total_cooling_latent_load_btu_h": 1207,
      "total_cooling_peak_load_btu_h": 13789,
      "calculated_cooling_tonnage": 1.15,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 160.9,
      "sensible_heat_ratio_shr": 0.912,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0026",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 15581,
      "heating_infiltration_loss_btu_h": 885,
      "total_peak_heating_load_btu_h": 16466,
      "summer_conduction_gain_btu_h": 10408,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 505,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 18327,
      "total_cooling_latent_load_btu_h": 1876,
      "total_cooling_peak_load_btu_h": 20203,
      "calculated_cooling_tonnage": 1.68,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 197.6,
      "sensible_heat_ratio_shr": 0.907,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0027",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 21333,
      "heating_infiltration_loss_btu_h": 1346,
      "total_peak_heating_load_btu_h": 22679,
      "summer_conduction_gain_btu_h": 14128,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 769,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 24563,
      "total_cooling_latent_load_btu_h": 2637,
      "total_cooling_peak_load_btu_h": 27200,
      "calculated_cooling_tonnage": 2.27,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 217.2,
      "sensible_heat_ratio_shr": 0.903,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0028",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 14069,
      "heating_infiltration_loss_btu_h": 3531,
      "total_peak_heating_load_btu_h": 17600,
      "summer_conduction_gain_btu_h": 8687,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 2017,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 21356,
      "total_cooling_latent_load_btu_h": 4895,
      "total_cooling_peak_load_btu_h": 26251,
      "calculated_cooling_tonnage": 2.19,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 37,
      "sensible_heat_ratio_shr": 0.814,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0029",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 21677,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 27929,
      "summer_conduction_gain_btu_h": 13314,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 3573,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 32288,
      "total_cooling_latent_load_btu_h": 8405,
      "total_cooling_peak_load_btu_h": 40693,
      "calculated_cooling_tonnage": 3.39,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 47.5,
      "sensible_heat_ratio_shr": 0.793,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0030",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 30224,
      "heating_infiltration_loss_btu_h": 9533,
      "total_peak_heating_load_btu_h": 39757,
      "summer_conduction_gain_btu_h": 18470,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 5448,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 44816,
      "total_cooling_latent_load_btu_h": 12596,
      "total_cooling_peak_load_btu_h": 57412,
      "calculated_cooling_tonnage": 4.78,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 50.6,
      "sensible_heat_ratio_shr": 0.781,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0031",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 14069,
      "heating_infiltration_loss_btu_h": 1455,
      "total_peak_heating_load_btu_h": 15524,
      "summer_conduction_gain_btu_h": 8687,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 832,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 20171,
      "total_cooling_latent_load_btu_h": 2370,
      "total_cooling_peak_load_btu_h": 22541,
      "calculated_cooling_tonnage": 1.88,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 59.6,
      "sensible_heat_ratio_shr": 0.895,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0032",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 21677,
      "heating_infiltration_loss_btu_h": 2574,
      "total_peak_heating_load_btu_h": 24251,
      "summer_conduction_gain_btu_h": 13314,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1471,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 30186,
      "total_cooling_latent_load_btu_h": 3931,
      "total_cooling_peak_load_btu_h": 34117,
      "calculated_cooling_tonnage": 2.84,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 76.1,
      "sensible_heat_ratio_shr": 0.885,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0033",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 30224,
      "heating_infiltration_loss_btu_h": 3924,
      "total_peak_heating_load_btu_h": 34148,
      "summer_conduction_gain_btu_h": 18470,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 2242,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 41610,
      "total_cooling_latent_load_btu_h": 5773,
      "total_cooling_peak_load_btu_h": 47383,
      "calculated_cooling_tonnage": 3.95,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 82.3,
      "sensible_heat_ratio_shr": 0.878,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0034",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 14069,
      "heating_infiltration_loss_btu_h": 499,
      "total_peak_heating_load_btu_h": 14568,
      "summer_conduction_gain_btu_h": 8687,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 285,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 19624,
      "total_cooling_latent_load_btu_h": 1207,
      "total_cooling_peak_load_btu_h": 20831,
      "calculated_cooling_tonnage": 1.74,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 72.4,
      "sensible_heat_ratio_shr": 0.942,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0035",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 21677,
      "heating_infiltration_loss_btu_h": 885,
      "total_peak_heating_load_btu_h": 22562,
      "summer_conduction_gain_btu_h": 13314,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 505,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 29220,
      "total_cooling_latent_load_btu_h": 1876,
      "total_cooling_peak_load_btu_h": 31096,
      "calculated_cooling_tonnage": 2.59,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 93.1,
      "sensible_heat_ratio_shr": 0.94,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0036",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 30224,
      "heating_infiltration_loss_btu_h": 1346,
      "total_peak_heating_load_btu_h": 31570,
      "summer_conduction_gain_btu_h": 18470,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 769,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 40137,
      "total_cooling_latent_load_btu_h": 2637,
      "total_cooling_peak_load_btu_h": 42774,
      "calculated_cooling_tonnage": 3.56,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 102.2,
      "sensible_heat_ratio_shr": 0.938,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0037",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 9879,
      "heating_infiltration_loss_btu_h": 3531,
      "total_peak_heating_load_btu_h": 13410,
      "summer_conduction_gain_btu_h": 6293,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 2017,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17434,
      "total_cooling_latent_load_btu_h": 4895,
      "total_cooling_peak_load_btu_h": 22329,
      "calculated_cooling_tonnage": 1.86,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 61.3,
      "sensible_heat_ratio_shr": 0.781,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0038",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 15293,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 21545,
      "summer_conduction_gain_btu_h": 9666,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 3573,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 26310,
      "total_cooling_latent_load_btu_h": 8405,
      "total_cooling_peak_load_btu_h": 34715,
      "calculated_cooling_tonnage": 2.89,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 73,
      "sensible_heat_ratio_shr": 0.758,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0039",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 21247,
      "heating_infiltration_loss_btu_h": 9533,
      "total_peak_heating_load_btu_h": 30780,
      "summer_conduction_gain_btu_h": 13340,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 5448,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 36410,
      "total_cooling_latent_load_btu_h": 12596,
      "total_cooling_peak_load_btu_h": 49006,
      "calculated_cooling_tonnage": 4.08,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 76.5,
      "sensible_heat_ratio_shr": 0.743,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0040",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 9879,
      "heating_infiltration_loss_btu_h": 1455,
      "total_peak_heating_load_btu_h": 11334,
      "summer_conduction_gain_btu_h": 6293,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 832,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16249,
      "total_cooling_latent_load_btu_h": 2370,
      "total_cooling_peak_load_btu_h": 18619,
      "calculated_cooling_tonnage": 1.55,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 93.5,
      "sensible_heat_ratio_shr": 0.873,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0041",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 15293,
      "heating_infiltration_loss_btu_h": 2574,
      "total_peak_heating_load_btu_h": 17867,
      "summer_conduction_gain_btu_h": 9666,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1471,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 24208,
      "total_cooling_latent_load_btu_h": 3931,
      "total_cooling_peak_load_btu_h": 28139,
      "calculated_cooling_tonnage": 2.34,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 113.7,
      "sensible_heat_ratio_shr": 0.86,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0042",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 21247,
      "heating_infiltration_loss_btu_h": 3924,
      "total_peak_heating_load_btu_h": 25171,
      "summer_conduction_gain_btu_h": 13340,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 2242,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 33204,
      "total_cooling_latent_load_btu_h": 5773,
      "total_cooling_peak_load_btu_h": 38977,
      "calculated_cooling_tonnage": 3.25,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 121.5,
      "sensible_heat_ratio_shr": 0.852,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0043",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 9879,
      "heating_infiltration_loss_btu_h": 499,
      "total_peak_heating_load_btu_h": 10378,
      "summer_conduction_gain_btu_h": 6293,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 285,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15702,
      "total_cooling_latent_load_btu_h": 1207,
      "total_cooling_peak_load_btu_h": 16909,
      "calculated_cooling_tonnage": 1.41,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 112.8,
      "sensible_heat_ratio_shr": 0.929,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0044",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 15293,
      "heating_infiltration_loss_btu_h": 885,
      "total_peak_heating_load_btu_h": 16178,
      "summer_conduction_gain_btu_h": 9666,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 505,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 23242,
      "total_cooling_latent_load_btu_h": 1876,
      "total_cooling_peak_load_btu_h": 25118,
      "calculated_cooling_tonnage": 2.09,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 139.2,
      "sensible_heat_ratio_shr": 0.925,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0045",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 21247,
      "heating_infiltration_loss_btu_h": 1346,
      "total_peak_heating_load_btu_h": 22593,
      "summer_conduction_gain_btu_h": 13340,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 769,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 31731,
      "total_cooling_latent_load_btu_h": 2637,
      "total_cooling_peak_load_btu_h": 34368,
      "calculated_cooling_tonnage": 2.86,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 151.7,
      "sensible_heat_ratio_shr": 0.923,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0046",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 8409,
      "heating_infiltration_loss_btu_h": 3531,
      "total_peak_heating_load_btu_h": 11940,
      "summer_conduction_gain_btu_h": 5453,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 2017,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 12881,
      "total_cooling_latent_load_btu_h": 4895,
      "total_cooling_peak_load_btu_h": 17776,
      "calculated_cooling_tonnage": 1.48,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 102.7,
      "sensible_heat_ratio_shr": 0.725,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0047",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 13053,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 19305,
      "summer_conduction_gain_btu_h": 8386,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 3573,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 19373,
      "total_cooling_latent_load_btu_h": 8405,
      "total_cooling_peak_load_btu_h": 27778,
      "calculated_cooling_tonnage": 2.31,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 116.5,
      "sensible_heat_ratio_shr": 0.697,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0048",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 18097,
      "heating_infiltration_loss_btu_h": 9533,
      "total_peak_heating_load_btu_h": 27630,
      "summer_conduction_gain_btu_h": 11540,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 5448,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 26654,
      "total_cooling_latent_load_btu_h": 12596,
      "total_cooling_peak_load_btu_h": 39250,
      "calculated_cooling_tonnage": 3.27,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 120.2,
      "sensible_heat_ratio_shr": 0.679,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0049",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 8409,
      "heating_infiltration_loss_btu_h": 1455,
      "total_peak_heating_load_btu_h": 9864,
      "summer_conduction_gain_btu_h": 5453,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 832,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 11696,
      "total_cooling_latent_load_btu_h": 2370,
      "total_cooling_peak_load_btu_h": 14066,
      "calculated_cooling_tonnage": 1.17,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 156.4,
      "sensible_heat_ratio_shr": 0.832,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0050",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 13053,
      "heating_infiltration_loss_btu_h": 2574,
      "total_peak_heating_load_btu_h": 15627,
      "summer_conduction_gain_btu_h": 8386,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1471,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 17271,
      "total_cooling_latent_load_btu_h": 3931,
      "total_cooling_peak_load_btu_h": 21202,
      "calculated_cooling_tonnage": 1.77,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 182.5,
      "sensible_heat_ratio_shr": 0.815,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0051",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 18097,
      "heating_infiltration_loss_btu_h": 3924,
      "total_peak_heating_load_btu_h": 22021,
      "summer_conduction_gain_btu_h": 11540,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 2242,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 23448,
      "total_cooling_latent_load_btu_h": 5773,
      "total_cooling_peak_load_btu_h": 29221,
      "calculated_cooling_tonnage": 2.44,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 195.1,
      "sensible_heat_ratio_shr": 0.802,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0052",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 8409,
      "heating_infiltration_loss_btu_h": 499,
      "total_peak_heating_load_btu_h": 8908,
      "summer_conduction_gain_btu_h": 5453,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 285,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 11149,
      "total_cooling_latent_load_btu_h": 1207,
      "total_cooling_peak_load_btu_h": 12356,
      "calculated_cooling_tonnage": 1.03,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 191.3,
      "sensible_heat_ratio_shr": 0.902,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0053",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 13053,
      "heating_infiltration_loss_btu_h": 885,
      "total_peak_heating_load_btu_h": 13938,
      "summer_conduction_gain_btu_h": 8386,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 505,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 16305,
      "total_cooling_latent_load_btu_h": 1876,
      "total_cooling_peak_load_btu_h": 18181,
      "calculated_cooling_tonnage": 1.52,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 228.9,
      "sensible_heat_ratio_shr": 0.897,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0054",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 18097,
      "heating_infiltration_loss_btu_h": 1346,
      "total_peak_heating_load_btu_h": 19443,
      "summer_conduction_gain_btu_h": 11540,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 769,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 21975,
      "total_cooling_latent_load_btu_h": 2637,
      "total_cooling_peak_load_btu_h": 24612,
      "calculated_cooling_tonnage": 2.05,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 251.2,
      "sensible_heat_ratio_shr": 0.893,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0055",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 13611,
      "heating_infiltration_loss_btu_h": 3531,
      "total_peak_heating_load_btu_h": 17142,
      "summer_conduction_gain_btu_h": 8321,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 2017,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 20990,
      "total_cooling_latent_load_btu_h": 4895,
      "total_cooling_peak_load_btu_h": 25885,
      "calculated_cooling_tonnage": 2.16,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 38.9,
      "sensible_heat_ratio_shr": 0.811,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0056",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 21030,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 27282,
      "summer_conduction_gain_btu_h": 12796,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 3573,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 31770,
      "total_cooling_latent_load_btu_h": 8405,
      "total_cooling_peak_load_btu_h": 40175,
      "calculated_cooling_tonnage": 3.35,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 49.3,
      "sensible_heat_ratio_shr": 0.791,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0057",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 29397,
      "heating_infiltration_loss_btu_h": 9533,
      "total_peak_heating_load_btu_h": 38930,
      "summer_conduction_gain_btu_h": 17808,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 5448,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 44154,
      "total_cooling_latent_load_btu_h": 12596,
      "total_cooling_peak_load_btu_h": 56750,
      "calculated_cooling_tonnage": 4.73,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 52.2,
      "sensible_heat_ratio_shr": 0.778,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0058",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 13611,
      "heating_infiltration_loss_btu_h": 1455,
      "total_peak_heating_load_btu_h": 15066,
      "summer_conduction_gain_btu_h": 8321,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 832,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 19805,
      "total_cooling_latent_load_btu_h": 2370,
      "total_cooling_peak_load_btu_h": 22175,
      "calculated_cooling_tonnage": 1.85,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 62.2,
      "sensible_heat_ratio_shr": 0.893,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0059",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 21030,
      "heating_infiltration_loss_btu_h": 2574,
      "total_peak_heating_load_btu_h": 23604,
      "summer_conduction_gain_btu_h": 12796,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1471,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 29668,
      "total_cooling_latent_load_btu_h": 3931,
      "total_cooling_peak_load_btu_h": 33599,
      "calculated_cooling_tonnage": 2.8,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 78.6,
      "sensible_heat_ratio_shr": 0.883,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0060",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 29397,
      "heating_infiltration_loss_btu_h": 3924,
      "total_peak_heating_load_btu_h": 33321,
      "summer_conduction_gain_btu_h": 17808,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 2242,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 40948,
      "total_cooling_latent_load_btu_h": 5773,
      "total_cooling_peak_load_btu_h": 46721,
      "calculated_cooling_tonnage": 3.89,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 85.1,
      "sensible_heat_ratio_shr": 0.876,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0061",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 13611,
      "heating_infiltration_loss_btu_h": 499,
      "total_peak_heating_load_btu_h": 14110,
      "summer_conduction_gain_btu_h": 8321,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 285,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 19258,
      "total_cooling_latent_load_btu_h": 1207,
      "total_cooling_peak_load_btu_h": 20465,
      "calculated_cooling_tonnage": 1.71,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 75.4,
      "sensible_heat_ratio_shr": 0.941,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0062",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 21030,
      "heating_infiltration_loss_btu_h": 885,
      "total_peak_heating_load_btu_h": 21915,
      "summer_conduction_gain_btu_h": 12796,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 505,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 28702,
      "total_cooling_latent_load_btu_h": 1876,
      "total_cooling_peak_load_btu_h": 30578,
      "calculated_cooling_tonnage": 2.55,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 96.1,
      "sensible_heat_ratio_shr": 0.939,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0063",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 29397,
      "heating_infiltration_loss_btu_h": 1346,
      "total_peak_heating_load_btu_h": 30743,
      "summer_conduction_gain_btu_h": 17808,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 769,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 39475,
      "total_cooling_latent_load_btu_h": 2637,
      "total_cooling_peak_load_btu_h": 42112,
      "calculated_cooling_tonnage": 3.51,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 105.1,
      "sensible_heat_ratio_shr": 0.937,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0064",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 9421,
      "heating_infiltration_loss_btu_h": 3531,
      "total_peak_heating_load_btu_h": 12952,
      "summer_conduction_gain_btu_h": 5927,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 2017,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17068,
      "total_cooling_latent_load_btu_h": 4895,
      "total_cooling_peak_load_btu_h": 21963,
      "calculated_cooling_tonnage": 1.83,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 63.9,
      "sensible_heat_ratio_shr": 0.777,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0065",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 14646,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 20898,
      "summer_conduction_gain_btu_h": 9148,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 3573,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 25792,
      "total_cooling_latent_load_btu_h": 8405,
      "total_cooling_peak_load_btu_h": 34197,
      "calculated_cooling_tonnage": 2.85,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 75.4,
      "sensible_heat_ratio_shr": 0.754,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0066",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 20419,
      "heating_infiltration_loss_btu_h": 9533,
      "total_peak_heating_load_btu_h": 29952,
      "summer_conduction_gain_btu_h": 12678,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 5448,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 35748,
      "total_cooling_latent_load_btu_h": 12596,
      "total_cooling_peak_load_btu_h": 48344,
      "calculated_cooling_tonnage": 4.03,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 78.7,
      "sensible_heat_ratio_shr": 0.739,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0067",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 9421,
      "heating_infiltration_loss_btu_h": 1455,
      "total_peak_heating_load_btu_h": 10876,
      "summer_conduction_gain_btu_h": 5927,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 832,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15883,
      "total_cooling_latent_load_btu_h": 2370,
      "total_cooling_peak_load_btu_h": 18253,
      "calculated_cooling_tonnage": 1.52,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 97.4,
      "sensible_heat_ratio_shr": 0.87,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0068",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 14646,
      "heating_infiltration_loss_btu_h": 2574,
      "total_peak_heating_load_btu_h": 17220,
      "summer_conduction_gain_btu_h": 9148,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1471,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 23690,
      "total_cooling_latent_load_btu_h": 3931,
      "total_cooling_peak_load_btu_h": 27621,
      "calculated_cooling_tonnage": 2.3,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 117.4,
      "sensible_heat_ratio_shr": 0.858,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0069",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 20419,
      "heating_infiltration_loss_btu_h": 3924,
      "total_peak_heating_load_btu_h": 24343,
      "summer_conduction_gain_btu_h": 12678,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 2242,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 32542,
      "total_cooling_latent_load_btu_h": 5773,
      "total_cooling_peak_load_btu_h": 38315,
      "calculated_cooling_tonnage": 3.19,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 125.7,
      "sensible_heat_ratio_shr": 0.849,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0070",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 9421,
      "heating_infiltration_loss_btu_h": 499,
      "total_peak_heating_load_btu_h": 9920,
      "summer_conduction_gain_btu_h": 5927,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 285,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15336,
      "total_cooling_latent_load_btu_h": 1207,
      "total_cooling_peak_load_btu_h": 16543,
      "calculated_cooling_tonnage": 1.38,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 117.4,
      "sensible_heat_ratio_shr": 0.927,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0071",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 14646,
      "heating_infiltration_loss_btu_h": 885,
      "total_peak_heating_load_btu_h": 15531,
      "summer_conduction_gain_btu_h": 9148,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 505,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 22724,
      "total_cooling_latent_load_btu_h": 1876,
      "total_cooling_peak_load_btu_h": 24600,
      "calculated_cooling_tonnage": 2.05,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 143.9,
      "sensible_heat_ratio_shr": 0.924,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0072",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 20419,
      "heating_infiltration_loss_btu_h": 1346,
      "total_peak_heating_load_btu_h": 21765,
      "summer_conduction_gain_btu_h": 12678,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 769,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 31069,
      "total_cooling_latent_load_btu_h": 2637,
      "total_cooling_peak_load_btu_h": 33706,
      "calculated_cooling_tonnage": 2.81,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 156.2,
      "sensible_heat_ratio_shr": 0.922,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0073",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 7951,
      "heating_infiltration_loss_btu_h": 3531,
      "total_peak_heating_load_btu_h": 11482,
      "summer_conduction_gain_btu_h": 5087,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 2017,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 12515,
      "total_cooling_latent_load_btu_h": 4895,
      "total_cooling_peak_load_btu_h": 17410,
      "calculated_cooling_tonnage": 1.45,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 106.9,
      "sensible_heat_ratio_shr": 0.719,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0074",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 12406,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 18658,
      "summer_conduction_gain_btu_h": 7868,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 3573,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 18855,
      "total_cooling_latent_load_btu_h": 8405,
      "total_cooling_peak_load_btu_h": 27260,
      "calculated_cooling_tonnage": 2.27,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 120.3,
      "sensible_heat_ratio_shr": 0.692,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0075",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 17269,
      "heating_infiltration_loss_btu_h": 9533,
      "total_peak_heating_load_btu_h": 26802,
      "summer_conduction_gain_btu_h": 10878,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 5448,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 25992,
      "total_cooling_latent_load_btu_h": 12596,
      "total_cooling_peak_load_btu_h": 38588,
      "calculated_cooling_tonnage": 3.22,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 123.6,
      "sensible_heat_ratio_shr": 0.674,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0076",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 7951,
      "heating_infiltration_loss_btu_h": 1455,
      "total_peak_heating_load_btu_h": 9406,
      "summer_conduction_gain_btu_h": 5087,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 832,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 11330,
      "total_cooling_latent_load_btu_h": 2370,
      "total_cooling_peak_load_btu_h": 13700,
      "calculated_cooling_tonnage": 1.14,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 163.2,
      "sensible_heat_ratio_shr": 0.827,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0077",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 12406,
      "heating_infiltration_loss_btu_h": 2574,
      "total_peak_heating_load_btu_h": 14980,
      "summer_conduction_gain_btu_h": 7868,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1471,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 16753,
      "total_cooling_latent_load_btu_h": 3931,
      "total_cooling_peak_load_btu_h": 20684,
      "calculated_cooling_tonnage": 1.72,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 190.7,
      "sensible_heat_ratio_shr": 0.81,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0078",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 17269,
      "heating_infiltration_loss_btu_h": 3924,
      "total_peak_heating_load_btu_h": 21193,
      "summer_conduction_gain_btu_h": 10878,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 2242,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 22786,
      "total_cooling_latent_load_btu_h": 5773,
      "total_cooling_peak_load_btu_h": 28559,
      "calculated_cooling_tonnage": 2.38,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 202.5,
      "sensible_heat_ratio_shr": 0.798,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0079",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 7951,
      "heating_infiltration_loss_btu_h": 499,
      "total_peak_heating_load_btu_h": 8450,
      "summer_conduction_gain_btu_h": 5087,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 285,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10783,
      "total_cooling_latent_load_btu_h": 1207,
      "total_cooling_peak_load_btu_h": 11990,
      "calculated_cooling_tonnage": 1,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 200,
      "sensible_heat_ratio_shr": 0.899,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0080",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 12406,
      "heating_infiltration_loss_btu_h": 885,
      "total_peak_heating_load_btu_h": 13291,
      "summer_conduction_gain_btu_h": 7868,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 505,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 15787,
      "total_cooling_latent_load_btu_h": 1876,
      "total_cooling_peak_load_btu_h": 17663,
      "calculated_cooling_tonnage": 1.47,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 240.1,
      "sensible_heat_ratio_shr": 0.894,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0081",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 17269,
      "heating_infiltration_loss_btu_h": 1346,
      "total_peak_heating_load_btu_h": 18615,
      "summer_conduction_gain_btu_h": 10878,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 769,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 21313,
      "total_cooling_latent_load_btu_h": 2637,
      "total_cooling_peak_load_btu_h": 23950,
      "calculated_cooling_tonnage": 2,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 260,
      "sensible_heat_ratio_shr": 0.89,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0082",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 13111,
      "heating_infiltration_loss_btu_h": 3531,
      "total_peak_heating_load_btu_h": 16642,
      "summer_conduction_gain_btu_h": 7921,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 2017,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 20590,
      "total_cooling_latent_load_btu_h": 4895,
      "total_cooling_peak_load_btu_h": 25485,
      "calculated_cooling_tonnage": 2.12,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 41.5,
      "sensible_heat_ratio_shr": 0.808,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0083",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 20325,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 26577,
      "summer_conduction_gain_btu_h": 12232,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 3573,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 31206,
      "total_cooling_latent_load_btu_h": 8405,
      "total_cooling_peak_load_btu_h": 39611,
      "calculated_cooling_tonnage": 3.3,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 51.5,
      "sensible_heat_ratio_shr": 0.788,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0084",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 28494,
      "heating_infiltration_loss_btu_h": 9533,
      "total_peak_heating_load_btu_h": 38027,
      "summer_conduction_gain_btu_h": 17085,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 5448,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 43431,
      "total_cooling_latent_load_btu_h": 12596,
      "total_cooling_peak_load_btu_h": 56027,
      "calculated_cooling_tonnage": 4.67,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 54.2,
      "sensible_heat_ratio_shr": 0.775,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0085",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 13111,
      "heating_infiltration_loss_btu_h": 1455,
      "total_peak_heating_load_btu_h": 14566,
      "summer_conduction_gain_btu_h": 7921,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 832,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 19405,
      "total_cooling_latent_load_btu_h": 2370,
      "total_cooling_peak_load_btu_h": 21775,
      "calculated_cooling_tonnage": 1.81,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 65.7,
      "sensible_heat_ratio_shr": 0.891,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0086",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 20325,
      "heating_infiltration_loss_btu_h": 2574,
      "total_peak_heating_load_btu_h": 22899,
      "summer_conduction_gain_btu_h": 12232,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1471,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 29104,
      "total_cooling_latent_load_btu_h": 3931,
      "total_cooling_peak_load_btu_h": 33035,
      "calculated_cooling_tonnage": 2.75,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 81.8,
      "sensible_heat_ratio_shr": 0.881,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0087",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 28494,
      "heating_infiltration_loss_btu_h": 3924,
      "total_peak_heating_load_btu_h": 32418,
      "summer_conduction_gain_btu_h": 17085,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 2242,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 40225,
      "total_cooling_latent_load_btu_h": 5773,
      "total_cooling_peak_load_btu_h": 45998,
      "calculated_cooling_tonnage": 3.83,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 88,
      "sensible_heat_ratio_shr": 0.874,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0088",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 13111,
      "heating_infiltration_loss_btu_h": 499,
      "total_peak_heating_load_btu_h": 13610,
      "summer_conduction_gain_btu_h": 7921,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 285,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 18858,
      "total_cooling_latent_load_btu_h": 1207,
      "total_cooling_peak_load_btu_h": 20065,
      "calculated_cooling_tonnage": 1.67,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 79.6,
      "sensible_heat_ratio_shr": 0.94,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0089",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 20325,
      "heating_infiltration_loss_btu_h": 885,
      "total_peak_heating_load_btu_h": 21210,
      "summer_conduction_gain_btu_h": 12232,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 505,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 28138,
      "total_cooling_latent_load_btu_h": 1876,
      "total_cooling_peak_load_btu_h": 30014,
      "calculated_cooling_tonnage": 2.5,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 100,
      "sensible_heat_ratio_shr": 0.937,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0090",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 28494,
      "heating_infiltration_loss_btu_h": 1346,
      "total_peak_heating_load_btu_h": 29840,
      "summer_conduction_gain_btu_h": 17085,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 769,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 38752,
      "total_cooling_latent_load_btu_h": 2637,
      "total_cooling_peak_load_btu_h": 41389,
      "calculated_cooling_tonnage": 3.45,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 108.7,
      "sensible_heat_ratio_shr": 0.936,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0091",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 8922,
      "heating_infiltration_loss_btu_h": 3531,
      "total_peak_heating_load_btu_h": 12453,
      "summer_conduction_gain_btu_h": 5527,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 2017,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16668,
      "total_cooling_latent_load_btu_h": 4895,
      "total_cooling_peak_load_btu_h": 21563,
      "calculated_cooling_tonnage": 1.8,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 66.7,
      "sensible_heat_ratio_shr": 0.773,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0092",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 13941,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 20193,
      "summer_conduction_gain_btu_h": 8584,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 3573,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 25228,
      "total_cooling_latent_load_btu_h": 8405,
      "total_cooling_peak_load_btu_h": 33633,
      "calculated_cooling_tonnage": 2.8,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 78.6,
      "sensible_heat_ratio_shr": 0.75,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0093",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 19516,
      "heating_infiltration_loss_btu_h": 9533,
      "total_peak_heating_load_btu_h": 29049,
      "summer_conduction_gain_btu_h": 11955,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 5448,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 35025,
      "total_cooling_latent_load_btu_h": 12596,
      "total_cooling_peak_load_btu_h": 47621,
      "calculated_cooling_tonnage": 3.97,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 81.4,
      "sensible_heat_ratio_shr": 0.735,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0094",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 8922,
      "heating_infiltration_loss_btu_h": 1455,
      "total_peak_heating_load_btu_h": 10377,
      "summer_conduction_gain_btu_h": 5527,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 832,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15483,
      "total_cooling_latent_load_btu_h": 2370,
      "total_cooling_peak_load_btu_h": 17853,
      "calculated_cooling_tonnage": 1.49,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 101.3,
      "sensible_heat_ratio_shr": 0.867,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0095",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 13941,
      "heating_infiltration_loss_btu_h": 2574,
      "total_peak_heating_load_btu_h": 16515,
      "summer_conduction_gain_btu_h": 8584,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1471,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 23126,
      "total_cooling_latent_load_btu_h": 3931,
      "total_cooling_peak_load_btu_h": 27057,
      "calculated_cooling_tonnage": 2.25,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 122.2,
      "sensible_heat_ratio_shr": 0.855,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0096",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 19516,
      "heating_infiltration_loss_btu_h": 3924,
      "total_peak_heating_load_btu_h": 23440,
      "summer_conduction_gain_btu_h": 11955,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 2242,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 31819,
      "total_cooling_latent_load_btu_h": 5773,
      "total_cooling_peak_load_btu_h": 37592,
      "calculated_cooling_tonnage": 3.13,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 130,
      "sensible_heat_ratio_shr": 0.846,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0097",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 8922,
      "heating_infiltration_loss_btu_h": 499,
      "total_peak_heating_load_btu_h": 9421,
      "summer_conduction_gain_btu_h": 5527,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 285,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14936,
      "total_cooling_latent_load_btu_h": 1207,
      "total_cooling_peak_load_btu_h": 16143,
      "calculated_cooling_tonnage": 1.35,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 122.2,
      "sensible_heat_ratio_shr": 0.925,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0098",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 13941,
      "heating_infiltration_loss_btu_h": 885,
      "total_peak_heating_load_btu_h": 14826,
      "summer_conduction_gain_btu_h": 8584,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 505,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 22160,
      "total_cooling_latent_load_btu_h": 1876,
      "total_cooling_peak_load_btu_h": 24036,
      "calculated_cooling_tonnage": 2,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 150,
      "sensible_heat_ratio_shr": 0.922,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0099",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 19516,
      "heating_infiltration_loss_btu_h": 1346,
      "total_peak_heating_load_btu_h": 20862,
      "summer_conduction_gain_btu_h": 11955,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 769,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 30346,
      "total_cooling_latent_load_btu_h": 2637,
      "total_cooling_peak_load_btu_h": 32983,
      "calculated_cooling_tonnage": 2.75,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 161.8,
      "sensible_heat_ratio_shr": 0.92,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0100",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 7452,
      "heating_infiltration_loss_btu_h": 3531,
      "total_peak_heating_load_btu_h": 10983,
      "summer_conduction_gain_btu_h": 4687,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 2017,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 12115,
      "total_cooling_latent_load_btu_h": 4895,
      "total_cooling_peak_load_btu_h": 17010,
      "calculated_cooling_tonnage": 1.42,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 111.3,
      "sensible_heat_ratio_shr": 0.712,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0101",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 11701,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 17953,
      "summer_conduction_gain_btu_h": 7304,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 3573,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 18291,
      "total_cooling_latent_load_btu_h": 8405,
      "total_cooling_peak_load_btu_h": 26696,
      "calculated_cooling_tonnage": 2.22,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 125.2,
      "sensible_heat_ratio_shr": 0.685,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0102",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 16366,
      "heating_infiltration_loss_btu_h": 9533,
      "total_peak_heating_load_btu_h": 25899,
      "summer_conduction_gain_btu_h": 10155,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 5448,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 25269,
      "total_cooling_latent_load_btu_h": 12596,
      "total_cooling_peak_load_btu_h": 37865,
      "calculated_cooling_tonnage": 3.16,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 127.8,
      "sensible_heat_ratio_shr": 0.667,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0103",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 7452,
      "heating_infiltration_loss_btu_h": 1455,
      "total_peak_heating_load_btu_h": 8907,
      "summer_conduction_gain_btu_h": 4687,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 832,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10930,
      "total_cooling_latent_load_btu_h": 2370,
      "total_cooling_peak_load_btu_h": 13300,
      "calculated_cooling_tonnage": 1.11,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 170.3,
      "sensible_heat_ratio_shr": 0.822,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0104",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 11701,
      "heating_infiltration_loss_btu_h": 2574,
      "total_peak_heating_load_btu_h": 14275,
      "summer_conduction_gain_btu_h": 7304,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1471,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 16189,
      "total_cooling_latent_load_btu_h": 3931,
      "total_cooling_peak_load_btu_h": 20120,
      "calculated_cooling_tonnage": 1.68,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 197.6,
      "sensible_heat_ratio_shr": 0.805,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0105",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 16366,
      "heating_infiltration_loss_btu_h": 3924,
      "total_peak_heating_load_btu_h": 20290,
      "summer_conduction_gain_btu_h": 10155,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 2242,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 22063,
      "total_cooling_latent_load_btu_h": 5773,
      "total_cooling_peak_load_btu_h": 27836,
      "calculated_cooling_tonnage": 2.32,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 210.3,
      "sensible_heat_ratio_shr": 0.793,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0106",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 7452,
      "heating_infiltration_loss_btu_h": 499,
      "total_peak_heating_load_btu_h": 7951,
      "summer_conduction_gain_btu_h": 4687,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 285,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10383,
      "total_cooling_latent_load_btu_h": 1207,
      "total_cooling_peak_load_btu_h": 11590,
      "calculated_cooling_tonnage": 0.97,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 209.3,
      "sensible_heat_ratio_shr": 0.896,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0107",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 11701,
      "heating_infiltration_loss_btu_h": 885,
      "total_peak_heating_load_btu_h": 12586,
      "summer_conduction_gain_btu_h": 7304,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 505,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 15223,
      "total_cooling_latent_load_btu_h": 1876,
      "total_cooling_peak_load_btu_h": 17099,
      "calculated_cooling_tonnage": 1.42,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 252.1,
      "sensible_heat_ratio_shr": 0.89,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0108",
      "climate_zone": "CZ-2",
      "climate_zone_name": "Hot-Humid (Orlando/Houston)",
      "outdoor_winter_db_f": 35,
      "outdoor_summer_db_f": 95,
      "outdoor_summer_wb_f": 78,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 16366,
      "heating_infiltration_loss_btu_h": 1346,
      "total_peak_heating_load_btu_h": 17712,
      "summer_conduction_gain_btu_h": 10155,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 769,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 20590,
      "total_cooling_latent_load_btu_h": 2637,
      "total_cooling_peak_load_btu_h": 23227,
      "calculated_cooling_tonnage": 1.94,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 271.1,
      "sensible_heat_ratio_shr": 0.886,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0109",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 19919,
      "heating_infiltration_loss_btu_h": 4539,
      "total_peak_heating_load_btu_h": 24458,
      "summer_conduction_gain_btu_h": 8887,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1816,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 21355,
      "total_cooling_latent_load_btu_h": 3538,
      "total_cooling_peak_load_btu_h": 24893,
      "calculated_cooling_tonnage": 2.07,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 44.9,
      "sensible_heat_ratio_shr": 0.858,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0110",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 30334,
      "heating_infiltration_loss_btu_h": 8038,
      "total_peak_heating_load_btu_h": 38372,
      "summer_conduction_gain_btu_h": 13408,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 3215,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 32024,
      "total_cooling_latent_load_btu_h": 6003,
      "total_cooling_peak_load_btu_h": 38027,
      "calculated_cooling_tonnage": 3.17,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 57.7,
      "sensible_heat_ratio_shr": 0.842,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0111",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 41886,
      "heating_infiltration_loss_btu_h": 12257,
      "total_peak_heating_load_btu_h": 54143,
      "summer_conduction_gain_btu_h": 18362,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 4903,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 44163,
      "total_cooling_latent_load_btu_h": 8934,
      "total_cooling_peak_load_btu_h": 53097,
      "calculated_cooling_tonnage": 4.42,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 62.9,
      "sensible_heat_ratio_shr": 0.832,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0112",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 19919,
      "heating_infiltration_loss_btu_h": 1871,
      "total_peak_heating_load_btu_h": 21790,
      "summer_conduction_gain_btu_h": 8887,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 748,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 20287,
      "total_cooling_latent_load_btu_h": 1811,
      "total_cooling_peak_load_btu_h": 22098,
      "calculated_cooling_tonnage": 1.84,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 63,
      "sensible_heat_ratio_shr": 0.918,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0113",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 30334,
      "heating_infiltration_loss_btu_h": 3310,
      "total_peak_heating_load_btu_h": 33644,
      "summer_conduction_gain_btu_h": 13408,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1324,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 30133,
      "total_cooling_latent_load_btu_h": 2942,
      "total_cooling_peak_load_btu_h": 33075,
      "calculated_cooling_tonnage": 2.76,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 81.2,
      "sensible_heat_ratio_shr": 0.911,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0114",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 41886,
      "heating_infiltration_loss_btu_h": 5045,
      "total_peak_heating_load_btu_h": 46931,
      "summer_conduction_gain_btu_h": 18362,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 2018,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 41278,
      "total_cooling_latent_load_btu_h": 4266,
      "total_cooling_peak_load_btu_h": 45544,
      "calculated_cooling_tonnage": 3.8,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 89.5,
      "sensible_heat_ratio_shr": 0.906,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0115",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 19919,
      "heating_infiltration_loss_btu_h": 642,
      "total_peak_heating_load_btu_h": 20561,
      "summer_conduction_gain_btu_h": 8887,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 257,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 19796,
      "total_cooling_latent_load_btu_h": 1015,
      "total_cooling_peak_load_btu_h": 20811,
      "calculated_cooling_tonnage": 1.73,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 73.4,
      "sensible_heat_ratio_shr": 0.951,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0116",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 30334,
      "heating_infiltration_loss_btu_h": 1137,
      "total_peak_heating_load_btu_h": 31471,
      "summer_conduction_gain_btu_h": 13408,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 455,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 29264,
      "total_cooling_latent_load_btu_h": 1536,
      "total_cooling_peak_load_btu_h": 30800,
      "calculated_cooling_tonnage": 2.57,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 94.6,
      "sensible_heat_ratio_shr": 0.95,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0117",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 41886,
      "heating_infiltration_loss_btu_h": 1730,
      "total_peak_heating_load_btu_h": 43616,
      "summer_conduction_gain_btu_h": 18362,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 692,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 39952,
      "total_cooling_latent_load_btu_h": 2120,
      "total_cooling_peak_load_btu_h": 42072,
      "calculated_cooling_tonnage": 3.51,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 105.1,
      "sensible_heat_ratio_shr": 0.95,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0118",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 14532,
      "heating_infiltration_loss_btu_h": 4539,
      "total_peak_heating_load_btu_h": 19071,
      "summer_conduction_gain_btu_h": 6732,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1816,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17672,
      "total_cooling_latent_load_btu_h": 3538,
      "total_cooling_peak_load_btu_h": 21210,
      "calculated_cooling_tonnage": 1.77,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 69.5,
      "sensible_heat_ratio_shr": 0.833,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0119",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 22126,
      "heating_infiltration_loss_btu_h": 8038,
      "total_peak_heating_load_btu_h": 30164,
      "summer_conduction_gain_btu_h": 10125,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 3215,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 26411,
      "total_cooling_latent_load_btu_h": 6003,
      "total_cooling_peak_load_btu_h": 32414,
      "calculated_cooling_tonnage": 2.7,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 85.2,
      "sensible_heat_ratio_shr": 0.815,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0120",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 30344,
      "heating_infiltration_loss_btu_h": 12257,
      "total_peak_heating_load_btu_h": 42601,
      "summer_conduction_gain_btu_h": 13745,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 4903,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 36270,
      "total_cooling_latent_load_btu_h": 8934,
      "total_cooling_peak_load_btu_h": 45204,
      "calculated_cooling_tonnage": 3.77,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 91,
      "sensible_heat_ratio_shr": 0.802,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0121",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 14532,
      "heating_infiltration_loss_btu_h": 1871,
      "total_peak_heating_load_btu_h": 16403,
      "summer_conduction_gain_btu_h": 6732,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 748,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16604,
      "total_cooling_latent_load_btu_h": 1811,
      "total_cooling_peak_load_btu_h": 18415,
      "calculated_cooling_tonnage": 1.53,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 96.1,
      "sensible_heat_ratio_shr": 0.902,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0122",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 22126,
      "heating_infiltration_loss_btu_h": 3310,
      "total_peak_heating_load_btu_h": 25436,
      "summer_conduction_gain_btu_h": 10125,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1324,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 24520,
      "total_cooling_latent_load_btu_h": 2942,
      "total_cooling_peak_load_btu_h": 27462,
      "calculated_cooling_tonnage": 2.29,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 118.3,
      "sensible_heat_ratio_shr": 0.893,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0123",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 30344,
      "heating_infiltration_loss_btu_h": 5045,
      "total_peak_heating_load_btu_h": 35389,
      "summer_conduction_gain_btu_h": 13745,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 2018,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 33385,
      "total_cooling_latent_load_btu_h": 4266,
      "total_cooling_peak_load_btu_h": 37651,
      "calculated_cooling_tonnage": 3.14,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 129.3,
      "sensible_heat_ratio_shr": 0.887,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0124",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 14532,
      "heating_infiltration_loss_btu_h": 642,
      "total_peak_heating_load_btu_h": 15174,
      "summer_conduction_gain_btu_h": 6732,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 257,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16113,
      "total_cooling_latent_load_btu_h": 1015,
      "total_cooling_peak_load_btu_h": 17128,
      "calculated_cooling_tonnage": 1.43,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 109.8,
      "sensible_heat_ratio_shr": 0.941,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0125",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 22126,
      "heating_infiltration_loss_btu_h": 1137,
      "total_peak_heating_load_btu_h": 23263,
      "summer_conduction_gain_btu_h": 10125,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 455,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 23651,
      "total_cooling_latent_load_btu_h": 1536,
      "total_cooling_peak_load_btu_h": 25187,
      "calculated_cooling_tonnage": 2.1,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 138.1,
      "sensible_heat_ratio_shr": 0.939,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0126",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 30344,
      "heating_infiltration_loss_btu_h": 1730,
      "total_peak_heating_load_btu_h": 32074,
      "summer_conduction_gain_btu_h": 13745,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 692,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 32059,
      "total_cooling_latent_load_btu_h": 2120,
      "total_cooling_peak_load_btu_h": 34179,
      "calculated_cooling_tonnage": 2.85,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 152.6,
      "sensible_heat_ratio_shr": 0.938,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0127",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 12642,
      "heating_infiltration_loss_btu_h": 4539,
      "total_peak_heating_load_btu_h": 17181,
      "summer_conduction_gain_btu_h": 5976,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1816,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13203,
      "total_cooling_latent_load_btu_h": 3538,
      "total_cooling_peak_load_btu_h": 16741,
      "calculated_cooling_tonnage": 1.4,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 114.3,
      "sensible_heat_ratio_shr": 0.789,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0128",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 19246,
      "heating_infiltration_loss_btu_h": 8038,
      "total_peak_heating_load_btu_h": 27284,
      "summer_conduction_gain_btu_h": 8973,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 3215,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 19602,
      "total_cooling_latent_load_btu_h": 6003,
      "total_cooling_peak_load_btu_h": 25605,
      "calculated_cooling_tonnage": 2.13,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 134.7,
      "sensible_heat_ratio_shr": 0.766,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0129",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 26294,
      "heating_infiltration_loss_btu_h": 12257,
      "total_peak_heating_load_btu_h": 38551,
      "summer_conduction_gain_btu_h": 12125,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 4903,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 26694,
      "total_cooling_latent_load_btu_h": 8934,
      "total_cooling_peak_load_btu_h": 35628,
      "calculated_cooling_tonnage": 2.97,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 142.4,
      "sensible_heat_ratio_shr": 0.749,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0130",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 12642,
      "heating_infiltration_loss_btu_h": 1871,
      "total_peak_heating_load_btu_h": 14513,
      "summer_conduction_gain_btu_h": 5976,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 748,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 12135,
      "total_cooling_latent_load_btu_h": 1811,
      "total_cooling_peak_load_btu_h": 13946,
      "calculated_cooling_tonnage": 1.16,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 158.6,
      "sensible_heat_ratio_shr": 0.87,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0131",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 19246,
      "heating_infiltration_loss_btu_h": 3310,
      "total_peak_heating_load_btu_h": 22556,
      "summer_conduction_gain_btu_h": 8973,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1324,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 17711,
      "total_cooling_latent_load_btu_h": 2942,
      "total_cooling_peak_load_btu_h": 20653,
      "calculated_cooling_tonnage": 1.72,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 190.7,
      "sensible_heat_ratio_shr": 0.858,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0132",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 26294,
      "heating_infiltration_loss_btu_h": 5045,
      "total_peak_heating_load_btu_h": 31339,
      "summer_conduction_gain_btu_h": 12125,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 2018,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 23809,
      "total_cooling_latent_load_btu_h": 4266,
      "total_cooling_peak_load_btu_h": 28075,
      "calculated_cooling_tonnage": 2.34,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 207.7,
      "sensible_heat_ratio_shr": 0.848,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0133",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 12642,
      "heating_infiltration_loss_btu_h": 642,
      "total_peak_heating_load_btu_h": 13284,
      "summer_conduction_gain_btu_h": 5976,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 257,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 11644,
      "total_cooling_latent_load_btu_h": 1015,
      "total_cooling_peak_load_btu_h": 12659,
      "calculated_cooling_tonnage": 1.05,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 185.7,
      "sensible_heat_ratio_shr": 0.92,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0134",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 19246,
      "heating_infiltration_loss_btu_h": 1137,
      "total_peak_heating_load_btu_h": 20383,
      "summer_conduction_gain_btu_h": 8973,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 455,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 16842,
      "total_cooling_latent_load_btu_h": 1536,
      "total_cooling_peak_load_btu_h": 18378,
      "calculated_cooling_tonnage": 1.53,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 226.8,
      "sensible_heat_ratio_shr": 0.916,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0135",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 26294,
      "heating_infiltration_loss_btu_h": 1730,
      "total_peak_heating_load_btu_h": 28024,
      "summer_conduction_gain_btu_h": 12125,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 692,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 22483,
      "total_cooling_latent_load_btu_h": 2120,
      "total_cooling_peak_load_btu_h": 24603,
      "calculated_cooling_tonnage": 2.05,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 251.2,
      "sensible_heat_ratio_shr": 0.914,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0136",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 17616,
      "heating_infiltration_loss_btu_h": 4539,
      "total_peak_heating_load_btu_h": 22155,
      "summer_conduction_gain_btu_h": 7556,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1816,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 20024,
      "total_cooling_latent_load_btu_h": 3538,
      "total_cooling_peak_load_btu_h": 23562,
      "calculated_cooling_tonnage": 1.96,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 53.1,
      "sensible_heat_ratio_shr": 0.85,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0137",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 27083,
      "heating_infiltration_loss_btu_h": 8038,
      "total_peak_heating_load_btu_h": 35121,
      "summer_conduction_gain_btu_h": 11530,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 3215,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 30146,
      "total_cooling_latent_load_btu_h": 6003,
      "total_cooling_peak_load_btu_h": 36149,
      "calculated_cooling_tonnage": 3.01,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 66.1,
      "sensible_heat_ratio_shr": 0.834,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0138",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 37726,
      "heating_infiltration_loss_btu_h": 12257,
      "total_peak_heating_load_btu_h": 49983,
      "summer_conduction_gain_btu_h": 15958,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 4903,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 41759,
      "total_cooling_latent_load_btu_h": 8934,
      "total_cooling_peak_load_btu_h": 50693,
      "calculated_cooling_tonnage": 4.22,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 70.6,
      "sensible_heat_ratio_shr": 0.824,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0139",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 17616,
      "heating_infiltration_loss_btu_h": 1871,
      "total_peak_heating_load_btu_h": 19487,
      "summer_conduction_gain_btu_h": 7556,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 748,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 18956,
      "total_cooling_latent_load_btu_h": 1811,
      "total_cooling_peak_load_btu_h": 20767,
      "calculated_cooling_tonnage": 1.73,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 73.4,
      "sensible_heat_ratio_shr": 0.913,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0140",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 27083,
      "heating_infiltration_loss_btu_h": 3310,
      "total_peak_heating_load_btu_h": 30393,
      "summer_conduction_gain_btu_h": 11530,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1324,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 28255,
      "total_cooling_latent_load_btu_h": 2942,
      "total_cooling_peak_load_btu_h": 31197,
      "calculated_cooling_tonnage": 2.6,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 92.3,
      "sensible_heat_ratio_shr": 0.906,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0141",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 37726,
      "heating_infiltration_loss_btu_h": 5045,
      "total_peak_heating_load_btu_h": 42771,
      "summer_conduction_gain_btu_h": 15958,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 2018,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 38874,
      "total_cooling_latent_load_btu_h": 4266,
      "total_cooling_peak_load_btu_h": 43140,
      "calculated_cooling_tonnage": 3.6,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 100,
      "sensible_heat_ratio_shr": 0.901,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0142",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 17616,
      "heating_infiltration_loss_btu_h": 642,
      "total_peak_heating_load_btu_h": 18258,
      "summer_conduction_gain_btu_h": 7556,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 257,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 18465,
      "total_cooling_latent_load_btu_h": 1015,
      "total_cooling_peak_load_btu_h": 19480,
      "calculated_cooling_tonnage": 1.62,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 85.2,
      "sensible_heat_ratio_shr": 0.948,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0143",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 27083,
      "heating_infiltration_loss_btu_h": 1137,
      "total_peak_heating_load_btu_h": 28220,
      "summer_conduction_gain_btu_h": 11530,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 455,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 27386,
      "total_cooling_latent_load_btu_h": 1536,
      "total_cooling_peak_load_btu_h": 28922,
      "calculated_cooling_tonnage": 2.41,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 107.5,
      "sensible_heat_ratio_shr": 0.947,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0144",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 37726,
      "heating_infiltration_loss_btu_h": 1730,
      "total_peak_heating_load_btu_h": 39456,
      "summer_conduction_gain_btu_h": 15958,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 692,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 37548,
      "total_cooling_latent_load_btu_h": 2120,
      "total_cooling_peak_load_btu_h": 39668,
      "calculated_cooling_tonnage": 3.31,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 117.5,
      "sensible_heat_ratio_shr": 0.947,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0145",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 12230,
      "heating_infiltration_loss_btu_h": 4539,
      "total_peak_heating_load_btu_h": 16769,
      "summer_conduction_gain_btu_h": 5402,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1816,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16342,
      "total_cooling_latent_load_btu_h": 3538,
      "total_cooling_peak_load_btu_h": 19880,
      "calculated_cooling_tonnage": 1.66,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 80.7,
      "sensible_heat_ratio_shr": 0.822,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0146",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 18875,
      "heating_infiltration_loss_btu_h": 8038,
      "total_peak_heating_load_btu_h": 26913,
      "summer_conduction_gain_btu_h": 8247,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 3215,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 24533,
      "total_cooling_latent_load_btu_h": 6003,
      "total_cooling_peak_load_btu_h": 30536,
      "calculated_cooling_tonnage": 2.54,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 96.9,
      "sensible_heat_ratio_shr": 0.803,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0147",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 26183,
      "heating_infiltration_loss_btu_h": 12257,
      "total_peak_heating_load_btu_h": 38440,
      "summer_conduction_gain_btu_h": 11341,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 4903,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 33866,
      "total_cooling_latent_load_btu_h": 8934,
      "total_cooling_peak_load_btu_h": 42800,
      "calculated_cooling_tonnage": 3.57,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 101.7,
      "sensible_heat_ratio_shr": 0.791,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0148",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 12230,
      "heating_infiltration_loss_btu_h": 1871,
      "total_peak_heating_load_btu_h": 14101,
      "summer_conduction_gain_btu_h": 5402,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 748,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15274,
      "total_cooling_latent_load_btu_h": 1811,
      "total_cooling_peak_load_btu_h": 17085,
      "calculated_cooling_tonnage": 1.42,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 111.3,
      "sensible_heat_ratio_shr": 0.894,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0149",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 18875,
      "heating_infiltration_loss_btu_h": 3310,
      "total_peak_heating_load_btu_h": 22185,
      "summer_conduction_gain_btu_h": 8247,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1324,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 22642,
      "total_cooling_latent_load_btu_h": 2942,
      "total_cooling_peak_load_btu_h": 25584,
      "calculated_cooling_tonnage": 2.13,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 134.7,
      "sensible_heat_ratio_shr": 0.885,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0150",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 26183,
      "heating_infiltration_loss_btu_h": 5045,
      "total_peak_heating_load_btu_h": 31228,
      "summer_conduction_gain_btu_h": 11341,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 2018,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 30981,
      "total_cooling_latent_load_btu_h": 4266,
      "total_cooling_peak_load_btu_h": 35247,
      "calculated_cooling_tonnage": 2.94,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 144.9,
      "sensible_heat_ratio_shr": 0.879,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0151",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 12230,
      "heating_infiltration_loss_btu_h": 642,
      "total_peak_heating_load_btu_h": 12872,
      "summer_conduction_gain_btu_h": 5402,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 257,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14783,
      "total_cooling_latent_load_btu_h": 1015,
      "total_cooling_peak_load_btu_h": 15798,
      "calculated_cooling_tonnage": 1.32,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 127.3,
      "sensible_heat_ratio_shr": 0.936,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0152",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 18875,
      "heating_infiltration_loss_btu_h": 1137,
      "total_peak_heating_load_btu_h": 20012,
      "summer_conduction_gain_btu_h": 8247,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 455,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 21773,
      "total_cooling_latent_load_btu_h": 1536,
      "total_cooling_peak_load_btu_h": 23309,
      "calculated_cooling_tonnage": 1.94,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 157.7,
      "sensible_heat_ratio_shr": 0.934,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0153",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 26183,
      "heating_infiltration_loss_btu_h": 1730,
      "total_peak_heating_load_btu_h": 27913,
      "summer_conduction_gain_btu_h": 11341,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 692,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 29655,
      "total_cooling_latent_load_btu_h": 2120,
      "total_cooling_peak_load_btu_h": 31775,
      "calculated_cooling_tonnage": 2.65,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 171.7,
      "sensible_heat_ratio_shr": 0.933,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0154",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 10340,
      "heating_infiltration_loss_btu_h": 4539,
      "total_peak_heating_load_btu_h": 14879,
      "summer_conduction_gain_btu_h": 4646,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1816,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 11873,
      "total_cooling_latent_load_btu_h": 3538,
      "total_cooling_peak_load_btu_h": 15411,
      "calculated_cooling_tonnage": 1.28,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 134.4,
      "sensible_heat_ratio_shr": 0.77,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0155",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 15995,
      "heating_infiltration_loss_btu_h": 8038,
      "total_peak_heating_load_btu_h": 24033,
      "summer_conduction_gain_btu_h": 7095,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 3215,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 17724,
      "total_cooling_latent_load_btu_h": 6003,
      "total_cooling_peak_load_btu_h": 23727,
      "calculated_cooling_tonnage": 1.98,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 152.5,
      "sensible_heat_ratio_shr": 0.747,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0156",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 22133,
      "heating_infiltration_loss_btu_h": 12257,
      "total_peak_heating_load_btu_h": 34390,
      "summer_conduction_gain_btu_h": 9721,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 4903,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 24290,
      "total_cooling_latent_load_btu_h": 8934,
      "total_cooling_peak_load_btu_h": 33224,
      "calculated_cooling_tonnage": 2.77,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 159.9,
      "sensible_heat_ratio_shr": 0.731,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0157",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 10340,
      "heating_infiltration_loss_btu_h": 1871,
      "total_peak_heating_load_btu_h": 12211,
      "summer_conduction_gain_btu_h": 4646,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 748,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10805,
      "total_cooling_latent_load_btu_h": 1811,
      "total_cooling_peak_load_btu_h": 12616,
      "calculated_cooling_tonnage": 1.05,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 185.7,
      "sensible_heat_ratio_shr": 0.856,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0158",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 15995,
      "heating_infiltration_loss_btu_h": 3310,
      "total_peak_heating_load_btu_h": 19305,
      "summer_conduction_gain_btu_h": 7095,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1324,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 15833,
      "total_cooling_latent_load_btu_h": 2942,
      "total_cooling_peak_load_btu_h": 18775,
      "calculated_cooling_tonnage": 1.56,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 220.5,
      "sensible_heat_ratio_shr": 0.843,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0159",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 22133,
      "heating_infiltration_loss_btu_h": 5045,
      "total_peak_heating_load_btu_h": 27178,
      "summer_conduction_gain_btu_h": 9721,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 2018,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 21405,
      "total_cooling_latent_load_btu_h": 4266,
      "total_cooling_peak_load_btu_h": 25671,
      "calculated_cooling_tonnage": 2.14,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 236.4,
      "sensible_heat_ratio_shr": 0.834,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0160",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 10340,
      "heating_infiltration_loss_btu_h": 642,
      "total_peak_heating_load_btu_h": 10982,
      "summer_conduction_gain_btu_h": 4646,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 257,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10314,
      "total_cooling_latent_load_btu_h": 1015,
      "total_cooling_peak_load_btu_h": 11329,
      "calculated_cooling_tonnage": 0.94,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 219.1,
      "sensible_heat_ratio_shr": 0.91,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0161",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 15995,
      "heating_infiltration_loss_btu_h": 1137,
      "total_peak_heating_load_btu_h": 17132,
      "summer_conduction_gain_btu_h": 7095,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 455,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 14964,
      "total_cooling_latent_load_btu_h": 1536,
      "total_cooling_peak_load_btu_h": 16500,
      "calculated_cooling_tonnage": 1.38,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 262.3,
      "sensible_heat_ratio_shr": 0.907,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0162",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 22133,
      "heating_infiltration_loss_btu_h": 1730,
      "total_peak_heating_load_btu_h": 23863,
      "summer_conduction_gain_btu_h": 9721,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 692,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 20079,
      "total_cooling_latent_load_btu_h": 2120,
      "total_cooling_peak_load_btu_h": 22199,
      "calculated_cooling_tonnage": 1.85,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 289.2,
      "sensible_heat_ratio_shr": 0.905,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0163",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 17027,
      "heating_infiltration_loss_btu_h": 4539,
      "total_peak_heating_load_btu_h": 21566,
      "summer_conduction_gain_btu_h": 7216,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1816,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 19684,
      "total_cooling_latent_load_btu_h": 3538,
      "total_cooling_peak_load_btu_h": 23222,
      "calculated_cooling_tonnage": 1.94,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 54.6,
      "sensible_heat_ratio_shr": 0.848,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0164",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 26251,
      "heating_infiltration_loss_btu_h": 8038,
      "total_peak_heating_load_btu_h": 34289,
      "summer_conduction_gain_btu_h": 11049,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 3215,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 29665,
      "total_cooling_latent_load_btu_h": 6003,
      "total_cooling_peak_load_btu_h": 35668,
      "calculated_cooling_tonnage": 2.97,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 68.4,
      "sensible_heat_ratio_shr": 0.832,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0165",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 36662,
      "heating_infiltration_loss_btu_h": 12257,
      "total_peak_heating_load_btu_h": 48919,
      "summer_conduction_gain_btu_h": 15343,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 4903,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 41144,
      "total_cooling_latent_load_btu_h": 8934,
      "total_cooling_peak_load_btu_h": 50078,
      "calculated_cooling_tonnage": 4.17,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 72.7,
      "sensible_heat_ratio_shr": 0.822,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0166",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 17027,
      "heating_infiltration_loss_btu_h": 1871,
      "total_peak_heating_load_btu_h": 18898,
      "summer_conduction_gain_btu_h": 7216,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 748,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 18616,
      "total_cooling_latent_load_btu_h": 1811,
      "total_cooling_peak_load_btu_h": 20427,
      "calculated_cooling_tonnage": 1.7,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 76.5,
      "sensible_heat_ratio_shr": 0.911,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0167",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 26251,
      "heating_infiltration_loss_btu_h": 3310,
      "total_peak_heating_load_btu_h": 29561,
      "summer_conduction_gain_btu_h": 11049,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1324,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 27774,
      "total_cooling_latent_load_btu_h": 2942,
      "total_cooling_peak_load_btu_h": 30716,
      "calculated_cooling_tonnage": 2.56,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 95.3,
      "sensible_heat_ratio_shr": 0.904,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0168",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 36662,
      "heating_infiltration_loss_btu_h": 5045,
      "total_peak_heating_load_btu_h": 41707,
      "summer_conduction_gain_btu_h": 15343,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 2018,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 38259,
      "total_cooling_latent_load_btu_h": 4266,
      "total_cooling_peak_load_btu_h": 42525,
      "calculated_cooling_tonnage": 3.54,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 103.4,
      "sensible_heat_ratio_shr": 0.9,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0169",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 17027,
      "heating_infiltration_loss_btu_h": 642,
      "total_peak_heating_load_btu_h": 17669,
      "summer_conduction_gain_btu_h": 7216,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 257,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 18125,
      "total_cooling_latent_load_btu_h": 1015,
      "total_cooling_peak_load_btu_h": 19140,
      "calculated_cooling_tonnage": 1.59,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 88.7,
      "sensible_heat_ratio_shr": 0.947,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0170",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 26251,
      "heating_infiltration_loss_btu_h": 1137,
      "total_peak_heating_load_btu_h": 27388,
      "summer_conduction_gain_btu_h": 11049,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 455,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 26905,
      "total_cooling_latent_load_btu_h": 1536,
      "total_cooling_peak_load_btu_h": 28441,
      "calculated_cooling_tonnage": 2.37,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 111,
      "sensible_heat_ratio_shr": 0.946,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0171",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 36662,
      "heating_infiltration_loss_btu_h": 1730,
      "total_peak_heating_load_btu_h": 38392,
      "summer_conduction_gain_btu_h": 15343,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 692,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 36933,
      "total_cooling_latent_load_btu_h": 2120,
      "total_cooling_peak_load_btu_h": 39053,
      "calculated_cooling_tonnage": 3.25,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 121.5,
      "sensible_heat_ratio_shr": 0.946,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0172",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 11641,
      "heating_infiltration_loss_btu_h": 4539,
      "total_peak_heating_load_btu_h": 16180,
      "summer_conduction_gain_btu_h": 5061,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1816,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16001,
      "total_cooling_latent_load_btu_h": 3538,
      "total_cooling_peak_load_btu_h": 19539,
      "calculated_cooling_tonnage": 1.63,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 84,
      "sensible_heat_ratio_shr": 0.819,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0173",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 18043,
      "heating_infiltration_loss_btu_h": 8038,
      "total_peak_heating_load_btu_h": 26081,
      "summer_conduction_gain_btu_h": 7766,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 3215,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 24052,
      "total_cooling_latent_load_btu_h": 6003,
      "total_cooling_peak_load_btu_h": 30055,
      "calculated_cooling_tonnage": 2.5,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 100,
      "sensible_heat_ratio_shr": 0.8,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0174",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 25119,
      "heating_infiltration_loss_btu_h": 12257,
      "total_peak_heating_load_btu_h": 37376,
      "summer_conduction_gain_btu_h": 10726,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 4903,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 33251,
      "total_cooling_latent_load_btu_h": 8934,
      "total_cooling_peak_load_btu_h": 42185,
      "calculated_cooling_tonnage": 3.52,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 104.5,
      "sensible_heat_ratio_shr": 0.788,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0175",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 11641,
      "heating_infiltration_loss_btu_h": 1871,
      "total_peak_heating_load_btu_h": 13512,
      "summer_conduction_gain_btu_h": 5061,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 748,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14933,
      "total_cooling_latent_load_btu_h": 1811,
      "total_cooling_peak_load_btu_h": 16744,
      "calculated_cooling_tonnage": 1.4,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 114.3,
      "sensible_heat_ratio_shr": 0.892,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0176",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 18043,
      "heating_infiltration_loss_btu_h": 3310,
      "total_peak_heating_load_btu_h": 21353,
      "summer_conduction_gain_btu_h": 7766,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1324,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 22161,
      "total_cooling_latent_load_btu_h": 2942,
      "total_cooling_peak_load_btu_h": 25103,
      "calculated_cooling_tonnage": 2.09,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 139.2,
      "sensible_heat_ratio_shr": 0.883,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0177",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 25119,
      "heating_infiltration_loss_btu_h": 5045,
      "total_peak_heating_load_btu_h": 30164,
      "summer_conduction_gain_btu_h": 10726,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 2018,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 30366,
      "total_cooling_latent_load_btu_h": 4266,
      "total_cooling_peak_load_btu_h": 34632,
      "calculated_cooling_tonnage": 2.89,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 149.1,
      "sensible_heat_ratio_shr": 0.877,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0178",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 11641,
      "heating_infiltration_loss_btu_h": 642,
      "total_peak_heating_load_btu_h": 12283,
      "summer_conduction_gain_btu_h": 5061,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 257,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14442,
      "total_cooling_latent_load_btu_h": 1015,
      "total_cooling_peak_load_btu_h": 15457,
      "calculated_cooling_tonnage": 1.29,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 132.6,
      "sensible_heat_ratio_shr": 0.934,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0179",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 18043,
      "heating_infiltration_loss_btu_h": 1137,
      "total_peak_heating_load_btu_h": 19180,
      "summer_conduction_gain_btu_h": 7766,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 455,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 21292,
      "total_cooling_latent_load_btu_h": 1536,
      "total_cooling_peak_load_btu_h": 22828,
      "calculated_cooling_tonnage": 1.9,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 163.2,
      "sensible_heat_ratio_shr": 0.933,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0180",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 25119,
      "heating_infiltration_loss_btu_h": 1730,
      "total_peak_heating_load_btu_h": 26849,
      "summer_conduction_gain_btu_h": 10726,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 692,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 29040,
      "total_cooling_latent_load_btu_h": 2120,
      "total_cooling_peak_load_btu_h": 31160,
      "calculated_cooling_tonnage": 2.6,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 176.9,
      "sensible_heat_ratio_shr": 0.932,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0181",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 9751,
      "heating_infiltration_loss_btu_h": 4539,
      "total_peak_heating_load_btu_h": 14290,
      "summer_conduction_gain_btu_h": 4305,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1816,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 11532,
      "total_cooling_latent_load_btu_h": 3538,
      "total_cooling_peak_load_btu_h": 15070,
      "calculated_cooling_tonnage": 1.26,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 138.1,
      "sensible_heat_ratio_shr": 0.765,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0182",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 15163,
      "heating_infiltration_loss_btu_h": 8038,
      "total_peak_heating_load_btu_h": 23201,
      "summer_conduction_gain_btu_h": 6614,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 3215,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 17243,
      "total_cooling_latent_load_btu_h": 6003,
      "total_cooling_peak_load_btu_h": 23246,
      "calculated_cooling_tonnage": 1.94,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 157.7,
      "sensible_heat_ratio_shr": 0.742,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0183",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 21069,
      "heating_infiltration_loss_btu_h": 12257,
      "total_peak_heating_load_btu_h": 33326,
      "summer_conduction_gain_btu_h": 9106,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 4903,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 23675,
      "total_cooling_latent_load_btu_h": 8934,
      "total_cooling_peak_load_btu_h": 32609,
      "calculated_cooling_tonnage": 2.72,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 164.7,
      "sensible_heat_ratio_shr": 0.726,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0184",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 9751,
      "heating_infiltration_loss_btu_h": 1871,
      "total_peak_heating_load_btu_h": 11622,
      "summer_conduction_gain_btu_h": 4305,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 748,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10464,
      "total_cooling_latent_load_btu_h": 1811,
      "total_cooling_peak_load_btu_h": 12275,
      "calculated_cooling_tonnage": 1.02,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 194.1,
      "sensible_heat_ratio_shr": 0.852,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0185",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 15163,
      "heating_infiltration_loss_btu_h": 3310,
      "total_peak_heating_load_btu_h": 18473,
      "summer_conduction_gain_btu_h": 6614,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1324,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 15352,
      "total_cooling_latent_load_btu_h": 2942,
      "total_cooling_peak_load_btu_h": 18294,
      "calculated_cooling_tonnage": 1.52,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 228.9,
      "sensible_heat_ratio_shr": 0.839,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0186",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 21069,
      "heating_infiltration_loss_btu_h": 5045,
      "total_peak_heating_load_btu_h": 26114,
      "summer_conduction_gain_btu_h": 9106,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 2018,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 20790,
      "total_cooling_latent_load_btu_h": 4266,
      "total_cooling_peak_load_btu_h": 25056,
      "calculated_cooling_tonnage": 2.09,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 244.5,
      "sensible_heat_ratio_shr": 0.83,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0187",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 9751,
      "heating_infiltration_loss_btu_h": 642,
      "total_peak_heating_load_btu_h": 10393,
      "summer_conduction_gain_btu_h": 4305,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 257,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9973,
      "total_cooling_latent_load_btu_h": 1015,
      "total_cooling_peak_load_btu_h": 10988,
      "calculated_cooling_tonnage": 0.92,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 226.1,
      "sensible_heat_ratio_shr": 0.908,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0188",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 15163,
      "heating_infiltration_loss_btu_h": 1137,
      "total_peak_heating_load_btu_h": 16300,
      "summer_conduction_gain_btu_h": 6614,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 455,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 14483,
      "total_cooling_latent_load_btu_h": 1536,
      "total_cooling_peak_load_btu_h": 16019,
      "calculated_cooling_tonnage": 1.33,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 275.9,
      "sensible_heat_ratio_shr": 0.904,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0189",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 21069,
      "heating_infiltration_loss_btu_h": 1730,
      "total_peak_heating_load_btu_h": 22799,
      "summer_conduction_gain_btu_h": 9106,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 692,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 19464,
      "total_cooling_latent_load_btu_h": 2120,
      "total_cooling_peak_load_btu_h": 21584,
      "calculated_cooling_tonnage": 1.8,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 300,
      "sensible_heat_ratio_shr": 0.902,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0190",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 16385,
      "heating_infiltration_loss_btu_h": 4539,
      "total_peak_heating_load_btu_h": 20924,
      "summer_conduction_gain_btu_h": 6845,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1816,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 19313,
      "total_cooling_latent_load_btu_h": 3538,
      "total_cooling_peak_load_btu_h": 22851,
      "calculated_cooling_tonnage": 1.9,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 57.9,
      "sensible_heat_ratio_shr": 0.845,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0191",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 25344,
      "heating_infiltration_loss_btu_h": 8038,
      "total_peak_heating_load_btu_h": 33382,
      "summer_conduction_gain_btu_h": 10525,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 3215,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 29141,
      "total_cooling_latent_load_btu_h": 6003,
      "total_cooling_peak_load_btu_h": 35144,
      "calculated_cooling_tonnage": 2.93,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 70.6,
      "sensible_heat_ratio_shr": 0.829,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0192",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 35501,
      "heating_infiltration_loss_btu_h": 12257,
      "total_peak_heating_load_btu_h": 47758,
      "summer_conduction_gain_btu_h": 14672,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 4903,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 40473,
      "total_cooling_latent_load_btu_h": 8934,
      "total_cooling_peak_load_btu_h": 49407,
      "calculated_cooling_tonnage": 4.12,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 74.8,
      "sensible_heat_ratio_shr": 0.819,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0193",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 16385,
      "heating_infiltration_loss_btu_h": 1871,
      "total_peak_heating_load_btu_h": 18256,
      "summer_conduction_gain_btu_h": 6845,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 748,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 18245,
      "total_cooling_latent_load_btu_h": 1811,
      "total_cooling_peak_load_btu_h": 20056,
      "calculated_cooling_tonnage": 1.67,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 79.6,
      "sensible_heat_ratio_shr": 0.91,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0194",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 25344,
      "heating_infiltration_loss_btu_h": 3310,
      "total_peak_heating_load_btu_h": 28654,
      "summer_conduction_gain_btu_h": 10525,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1324,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 27250,
      "total_cooling_latent_load_btu_h": 2942,
      "total_cooling_peak_load_btu_h": 30192,
      "calculated_cooling_tonnage": 2.52,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 98.4,
      "sensible_heat_ratio_shr": 0.903,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0195",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 35501,
      "heating_infiltration_loss_btu_h": 5045,
      "total_peak_heating_load_btu_h": 40546,
      "summer_conduction_gain_btu_h": 14672,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 2018,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 37588,
      "total_cooling_latent_load_btu_h": 4266,
      "total_cooling_peak_load_btu_h": 41854,
      "calculated_cooling_tonnage": 3.49,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 106.3,
      "sensible_heat_ratio_shr": 0.898,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0196",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 16385,
      "heating_infiltration_loss_btu_h": 642,
      "total_peak_heating_load_btu_h": 17027,
      "summer_conduction_gain_btu_h": 6845,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 257,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17754,
      "total_cooling_latent_load_btu_h": 1015,
      "total_cooling_peak_load_btu_h": 18769,
      "calculated_cooling_tonnage": 1.56,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 92.3,
      "sensible_heat_ratio_shr": 0.946,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0197",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 25344,
      "heating_infiltration_loss_btu_h": 1137,
      "total_peak_heating_load_btu_h": 26481,
      "summer_conduction_gain_btu_h": 10525,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 455,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 26381,
      "total_cooling_latent_load_btu_h": 1536,
      "total_cooling_peak_load_btu_h": 27917,
      "calculated_cooling_tonnage": 2.33,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 114.6,
      "sensible_heat_ratio_shr": 0.945,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0198",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 35501,
      "heating_infiltration_loss_btu_h": 1730,
      "total_peak_heating_load_btu_h": 37231,
      "summer_conduction_gain_btu_h": 14672,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 692,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 36262,
      "total_cooling_latent_load_btu_h": 2120,
      "total_cooling_peak_load_btu_h": 38382,
      "calculated_cooling_tonnage": 3.2,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 125,
      "sensible_heat_ratio_shr": 0.945,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0199",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 10998,
      "heating_infiltration_loss_btu_h": 4539,
      "total_peak_heating_load_btu_h": 15537,
      "summer_conduction_gain_btu_h": 4690,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1816,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15630,
      "total_cooling_latent_load_btu_h": 3538,
      "total_cooling_peak_load_btu_h": 19168,
      "calculated_cooling_tonnage": 1.6,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 87.5,
      "sensible_heat_ratio_shr": 0.815,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0200",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 17136,
      "heating_infiltration_loss_btu_h": 8038,
      "total_peak_heating_load_btu_h": 25174,
      "summer_conduction_gain_btu_h": 7242,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 3215,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 23528,
      "total_cooling_latent_load_btu_h": 6003,
      "total_cooling_peak_load_btu_h": 29531,
      "calculated_cooling_tonnage": 2.46,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 103.3,
      "sensible_heat_ratio_shr": 0.797,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0201",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 23958,
      "heating_infiltration_loss_btu_h": 12257,
      "total_peak_heating_load_btu_h": 36215,
      "summer_conduction_gain_btu_h": 10055,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 4903,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 32580,
      "total_cooling_latent_load_btu_h": 8934,
      "total_cooling_peak_load_btu_h": 41514,
      "calculated_cooling_tonnage": 3.46,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 108.1,
      "sensible_heat_ratio_shr": 0.785,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0202",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 10998,
      "heating_infiltration_loss_btu_h": 1871,
      "total_peak_heating_load_btu_h": 12869,
      "summer_conduction_gain_btu_h": 4690,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 748,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14562,
      "total_cooling_latent_load_btu_h": 1811,
      "total_cooling_peak_load_btu_h": 16373,
      "calculated_cooling_tonnage": 1.36,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 120.6,
      "sensible_heat_ratio_shr": 0.889,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0203",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 17136,
      "heating_infiltration_loss_btu_h": 3310,
      "total_peak_heating_load_btu_h": 20446,
      "summer_conduction_gain_btu_h": 7242,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1324,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 21637,
      "total_cooling_latent_load_btu_h": 2942,
      "total_cooling_peak_load_btu_h": 24579,
      "calculated_cooling_tonnage": 2.05,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 143.9,
      "sensible_heat_ratio_shr": 0.88,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0204",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 23958,
      "heating_infiltration_loss_btu_h": 5045,
      "total_peak_heating_load_btu_h": 29003,
      "summer_conduction_gain_btu_h": 10055,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 2018,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 29695,
      "total_cooling_latent_load_btu_h": 4266,
      "total_cooling_peak_load_btu_h": 33961,
      "calculated_cooling_tonnage": 2.83,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 154.4,
      "sensible_heat_ratio_shr": 0.874,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0205",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 10998,
      "heating_infiltration_loss_btu_h": 642,
      "total_peak_heating_load_btu_h": 11640,
      "summer_conduction_gain_btu_h": 4690,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 257,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14071,
      "total_cooling_latent_load_btu_h": 1015,
      "total_cooling_peak_load_btu_h": 15086,
      "calculated_cooling_tonnage": 1.26,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 138.1,
      "sensible_heat_ratio_shr": 0.933,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0206",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 17136,
      "heating_infiltration_loss_btu_h": 1137,
      "total_peak_heating_load_btu_h": 18273,
      "summer_conduction_gain_btu_h": 7242,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 455,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 20768,
      "total_cooling_latent_load_btu_h": 1536,
      "total_cooling_peak_load_btu_h": 22304,
      "calculated_cooling_tonnage": 1.86,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 168.8,
      "sensible_heat_ratio_shr": 0.931,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0207",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 23958,
      "heating_infiltration_loss_btu_h": 1730,
      "total_peak_heating_load_btu_h": 25688,
      "summer_conduction_gain_btu_h": 10055,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 692,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 28369,
      "total_cooling_latent_load_btu_h": 2120,
      "total_cooling_peak_load_btu_h": 30489,
      "calculated_cooling_tonnage": 2.54,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 183.5,
      "sensible_heat_ratio_shr": 0.93,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0208",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 9108,
      "heating_infiltration_loss_btu_h": 4539,
      "total_peak_heating_load_btu_h": 13647,
      "summer_conduction_gain_btu_h": 3934,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1816,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 11161,
      "total_cooling_latent_load_btu_h": 3538,
      "total_cooling_peak_load_btu_h": 14699,
      "calculated_cooling_tonnage": 1.22,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 145.9,
      "sensible_heat_ratio_shr": 0.759,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0209",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 14256,
      "heating_infiltration_loss_btu_h": 8038,
      "total_peak_heating_load_btu_h": 22294,
      "summer_conduction_gain_btu_h": 6090,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 3215,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 16719,
      "total_cooling_latent_load_btu_h": 6003,
      "total_cooling_peak_load_btu_h": 22722,
      "calculated_cooling_tonnage": 1.89,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 164.6,
      "sensible_heat_ratio_shr": 0.736,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0210",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 19908,
      "heating_infiltration_loss_btu_h": 12257,
      "total_peak_heating_load_btu_h": 32165,
      "summer_conduction_gain_btu_h": 8435,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 4903,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 23004,
      "total_cooling_latent_load_btu_h": 8934,
      "total_cooling_peak_load_btu_h": 31938,
      "calculated_cooling_tonnage": 2.66,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 170.7,
      "sensible_heat_ratio_shr": 0.72,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0211",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 9108,
      "heating_infiltration_loss_btu_h": 1871,
      "total_peak_heating_load_btu_h": 10979,
      "summer_conduction_gain_btu_h": 3934,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 748,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10093,
      "total_cooling_latent_load_btu_h": 1811,
      "total_cooling_peak_load_btu_h": 11904,
      "calculated_cooling_tonnage": 0.99,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 203,
      "sensible_heat_ratio_shr": 0.848,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0212",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 14256,
      "heating_infiltration_loss_btu_h": 3310,
      "total_peak_heating_load_btu_h": 17566,
      "summer_conduction_gain_btu_h": 6090,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1324,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 14828,
      "total_cooling_latent_load_btu_h": 2942,
      "total_cooling_peak_load_btu_h": 17770,
      "calculated_cooling_tonnage": 1.48,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 237.8,
      "sensible_heat_ratio_shr": 0.834,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0213",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 19908,
      "heating_infiltration_loss_btu_h": 5045,
      "total_peak_heating_load_btu_h": 24953,
      "summer_conduction_gain_btu_h": 8435,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 2018,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 20119,
      "total_cooling_latent_load_btu_h": 4266,
      "total_cooling_peak_load_btu_h": 24385,
      "calculated_cooling_tonnage": 2.03,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 254.7,
      "sensible_heat_ratio_shr": 0.825,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0214",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 9108,
      "heating_infiltration_loss_btu_h": 642,
      "total_peak_heating_load_btu_h": 9750,
      "summer_conduction_gain_btu_h": 3934,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 257,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9602,
      "total_cooling_latent_load_btu_h": 1015,
      "total_cooling_peak_load_btu_h": 10617,
      "calculated_cooling_tonnage": 0.88,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 240.9,
      "sensible_heat_ratio_shr": 0.904,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0215",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 14256,
      "heating_infiltration_loss_btu_h": 1137,
      "total_peak_heating_load_btu_h": 15393,
      "summer_conduction_gain_btu_h": 6090,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 455,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 13959,
      "total_cooling_latent_load_btu_h": 1536,
      "total_cooling_peak_load_btu_h": 15495,
      "calculated_cooling_tonnage": 1.29,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 287.6,
      "sensible_heat_ratio_shr": 0.901,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0216",
      "climate_zone": "CZ-3",
      "climate_zone_name": "Warm (Atlanta/Dallas)",
      "outdoor_winter_db_f": 25,
      "outdoor_summer_db_f": 93,
      "outdoor_summer_wb_f": 75,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 19908,
      "heating_infiltration_loss_btu_h": 1730,
      "total_peak_heating_load_btu_h": 21638,
      "summer_conduction_gain_btu_h": 8435,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 692,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 18793,
      "total_cooling_latent_load_btu_h": 2120,
      "total_cooling_peak_load_btu_h": 20913,
      "calculated_cooling_tonnage": 1.74,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 313.8,
      "sensible_heat_ratio_shr": 0.899,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0217",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 24345,
      "heating_infiltration_loss_btu_h": 5548,
      "total_peak_heating_load_btu_h": 29893,
      "summer_conduction_gain_btu_h": 7730,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1513,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 19895,
      "total_cooling_latent_load_btu_h": 2860,
      "total_cooling_peak_load_btu_h": 22755,
      "calculated_cooling_tonnage": 1.9,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 57.9,
      "sensible_heat_ratio_shr": 0.874,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0218",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 37074,
      "heating_infiltration_loss_btu_h": 9825,
      "total_peak_heating_load_btu_h": 46899,
      "summer_conduction_gain_btu_h": 11671,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 2679,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 29751,
      "total_cooling_latent_load_btu_h": 4803,
      "total_cooling_peak_load_btu_h": 34554,
      "calculated_cooling_tonnage": 2.88,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 73.6,
      "sensible_heat_ratio_shr": 0.861,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0219",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 51194,
      "heating_infiltration_loss_btu_h": 14981,
      "total_peak_heating_load_btu_h": 66175,
      "summer_conduction_gain_btu_h": 15980,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 4086,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 40964,
      "total_cooling_latent_load_btu_h": 7103,
      "total_cooling_peak_load_btu_h": 48067,
      "calculated_cooling_tonnage": 4.01,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 79.6,
      "sensible_heat_ratio_shr": 0.852,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0220",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 24345,
      "heating_infiltration_loss_btu_h": 2287,
      "total_peak_heating_load_btu_h": 26632,
      "summer_conduction_gain_btu_h": 7730,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 624,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 19006,
      "total_cooling_latent_load_btu_h": 1532,
      "total_cooling_peak_load_btu_h": 20538,
      "calculated_cooling_tonnage": 1.71,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 75.4,
      "sensible_heat_ratio_shr": 0.925,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0221",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 37074,
      "heating_infiltration_loss_btu_h": 4045,
      "total_peak_heating_load_btu_h": 41119,
      "summer_conduction_gain_btu_h": 11671,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1103,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 28175,
      "total_cooling_latent_load_btu_h": 2448,
      "total_cooling_peak_load_btu_h": 30623,
      "calculated_cooling_tonnage": 2.55,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 96.1,
      "sensible_heat_ratio_shr": 0.92,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0222",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 51194,
      "heating_infiltration_loss_btu_h": 6166,
      "total_peak_heating_load_btu_h": 57360,
      "summer_conduction_gain_btu_h": 15980,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 1682,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 38560,
      "total_cooling_latent_load_btu_h": 3512,
      "total_cooling_peak_load_btu_h": 42072,
      "calculated_cooling_tonnage": 3.51,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 105.1,
      "sensible_heat_ratio_shr": 0.917,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0223",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 24345,
      "heating_infiltration_loss_btu_h": 784,
      "total_peak_heating_load_btu_h": 25129,
      "summer_conduction_gain_btu_h": 7730,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 214,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 18596,
      "total_cooling_latent_load_btu_h": 919,
      "total_cooling_peak_load_btu_h": 19515,
      "calculated_cooling_tonnage": 1.63,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 84,
      "sensible_heat_ratio_shr": 0.953,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0224",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 37074,
      "heating_infiltration_loss_btu_h": 1390,
      "total_peak_heating_load_btu_h": 38464,
      "summer_conduction_gain_btu_h": 11671,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 379,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 27451,
      "total_cooling_latent_load_btu_h": 1366,
      "total_cooling_peak_load_btu_h": 28817,
      "calculated_cooling_tonnage": 2.4,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 108.3,
      "sensible_heat_ratio_shr": 0.953,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0225",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 51194,
      "heating_infiltration_loss_btu_h": 2115,
      "total_peak_heating_load_btu_h": 53309,
      "summer_conduction_gain_btu_h": 15980,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 577,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 37455,
      "total_cooling_latent_load_btu_h": 1862,
      "total_cooling_peak_load_btu_h": 39317,
      "calculated_cooling_tonnage": 3.28,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 119.5,
      "sensible_heat_ratio_shr": 0.953,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0226",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 17762,
      "heating_infiltration_loss_btu_h": 5548,
      "total_peak_heating_load_btu_h": 23310,
      "summer_conduction_gain_btu_h": 5934,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1513,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16571,
      "total_cooling_latent_load_btu_h": 2860,
      "total_cooling_peak_load_btu_h": 19431,
      "calculated_cooling_tonnage": 1.62,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 85.2,
      "sensible_heat_ratio_shr": 0.853,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0227",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 27042,
      "heating_infiltration_loss_btu_h": 9825,
      "total_peak_heating_load_btu_h": 36867,
      "summer_conduction_gain_btu_h": 8935,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 2679,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 24685,
      "total_cooling_latent_load_btu_h": 4803,
      "total_cooling_peak_load_btu_h": 29488,
      "calculated_cooling_tonnage": 2.46,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 103.3,
      "sensible_heat_ratio_shr": 0.837,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0228",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 37087,
      "heating_infiltration_loss_btu_h": 14981,
      "total_peak_heating_load_btu_h": 52068,
      "summer_conduction_gain_btu_h": 12132,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 4086,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 33840,
      "total_cooling_latent_load_btu_h": 7103,
      "total_cooling_peak_load_btu_h": 40943,
      "calculated_cooling_tonnage": 3.41,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 111.1,
      "sensible_heat_ratio_shr": 0.827,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0229",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 17762,
      "heating_infiltration_loss_btu_h": 2287,
      "total_peak_heating_load_btu_h": 20049,
      "summer_conduction_gain_btu_h": 5934,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 624,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15682,
      "total_cooling_latent_load_btu_h": 1532,
      "total_cooling_peak_load_btu_h": 17214,
      "calculated_cooling_tonnage": 1.43,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 109.8,
      "sensible_heat_ratio_shr": 0.911,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0230",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 27042,
      "heating_infiltration_loss_btu_h": 4045,
      "total_peak_heating_load_btu_h": 31087,
      "summer_conduction_gain_btu_h": 8935,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1103,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 23109,
      "total_cooling_latent_load_btu_h": 2448,
      "total_cooling_peak_load_btu_h": 25557,
      "calculated_cooling_tonnage": 2.13,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 134.7,
      "sensible_heat_ratio_shr": 0.904,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0231",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 37087,
      "heating_infiltration_loss_btu_h": 6166,
      "total_peak_heating_load_btu_h": 43253,
      "summer_conduction_gain_btu_h": 12132,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 1682,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 31436,
      "total_cooling_latent_load_btu_h": 3512,
      "total_cooling_peak_load_btu_h": 34948,
      "calculated_cooling_tonnage": 2.91,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 147.4,
      "sensible_heat_ratio_shr": 0.9,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0232",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 17762,
      "heating_infiltration_loss_btu_h": 784,
      "total_peak_heating_load_btu_h": 18546,
      "summer_conduction_gain_btu_h": 5934,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 214,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15272,
      "total_cooling_latent_load_btu_h": 919,
      "total_cooling_peak_load_btu_h": 16191,
      "calculated_cooling_tonnage": 1.35,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 122.2,
      "sensible_heat_ratio_shr": 0.943,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0233",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 27042,
      "heating_infiltration_loss_btu_h": 1390,
      "total_peak_heating_load_btu_h": 28432,
      "summer_conduction_gain_btu_h": 8935,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 379,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 22385,
      "total_cooling_latent_load_btu_h": 1366,
      "total_cooling_peak_load_btu_h": 23751,
      "calculated_cooling_tonnage": 1.98,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 152.5,
      "sensible_heat_ratio_shr": 0.942,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0234",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 37087,
      "heating_infiltration_loss_btu_h": 2115,
      "total_peak_heating_load_btu_h": 39202,
      "summer_conduction_gain_btu_h": 12132,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 577,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 30331,
      "total_cooling_latent_load_btu_h": 1862,
      "total_cooling_peak_load_btu_h": 32193,
      "calculated_cooling_tonnage": 2.68,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 168.7,
      "sensible_heat_ratio_shr": 0.942,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0235",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 15452,
      "heating_infiltration_loss_btu_h": 5548,
      "total_peak_heating_load_btu_h": 21000,
      "summer_conduction_gain_btu_h": 5304,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1513,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 12228,
      "total_cooling_latent_load_btu_h": 2860,
      "total_cooling_peak_load_btu_h": 15088,
      "calculated_cooling_tonnage": 1.26,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 138.1,
      "sensible_heat_ratio_shr": 0.81,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0236",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 23522,
      "heating_infiltration_loss_btu_h": 9825,
      "total_peak_heating_load_btu_h": 33347,
      "summer_conduction_gain_btu_h": 7975,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 2679,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 18068,
      "total_cooling_latent_load_btu_h": 4803,
      "total_cooling_peak_load_btu_h": 22871,
      "calculated_cooling_tonnage": 1.91,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 161.8,
      "sensible_heat_ratio_shr": 0.79,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0237",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 32137,
      "heating_infiltration_loss_btu_h": 14981,
      "total_peak_heating_load_btu_h": 47118,
      "summer_conduction_gain_btu_h": 10782,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 4086,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 24534,
      "total_cooling_latent_load_btu_h": 7103,
      "total_cooling_peak_load_btu_h": 31637,
      "calculated_cooling_tonnage": 2.64,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 172.7,
      "sensible_heat_ratio_shr": 0.775,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0238",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 15452,
      "heating_infiltration_loss_btu_h": 2287,
      "total_peak_heating_load_btu_h": 17739,
      "summer_conduction_gain_btu_h": 5304,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 624,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 11339,
      "total_cooling_latent_load_btu_h": 1532,
      "total_cooling_peak_load_btu_h": 12871,
      "calculated_cooling_tonnage": 1.07,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 180.4,
      "sensible_heat_ratio_shr": 0.881,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0239",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 23522,
      "heating_infiltration_loss_btu_h": 4045,
      "total_peak_heating_load_btu_h": 27567,
      "summer_conduction_gain_btu_h": 7975,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1103,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 16492,
      "total_cooling_latent_load_btu_h": 2448,
      "total_cooling_peak_load_btu_h": 18940,
      "calculated_cooling_tonnage": 1.58,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 216.5,
      "sensible_heat_ratio_shr": 0.871,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0240",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 32137,
      "heating_infiltration_loss_btu_h": 6166,
      "total_peak_heating_load_btu_h": 38303,
      "summer_conduction_gain_btu_h": 10782,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 1682,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 22130,
      "total_cooling_latent_load_btu_h": 3512,
      "total_cooling_peak_load_btu_h": 25642,
      "calculated_cooling_tonnage": 2.14,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 236.4,
      "sensible_heat_ratio_shr": 0.863,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0241",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 15452,
      "heating_infiltration_loss_btu_h": 784,
      "total_peak_heating_load_btu_h": 16236,
      "summer_conduction_gain_btu_h": 5304,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 214,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10929,
      "total_cooling_latent_load_btu_h": 919,
      "total_cooling_peak_load_btu_h": 11848,
      "calculated_cooling_tonnage": 0.99,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 203,
      "sensible_heat_ratio_shr": 0.922,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0242",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 23522,
      "heating_infiltration_loss_btu_h": 1390,
      "total_peak_heating_load_btu_h": 24912,
      "summer_conduction_gain_btu_h": 7975,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 379,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 15768,
      "total_cooling_latent_load_btu_h": 1366,
      "total_cooling_peak_load_btu_h": 17134,
      "calculated_cooling_tonnage": 1.43,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 249.7,
      "sensible_heat_ratio_shr": 0.92,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0243",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 32137,
      "heating_infiltration_loss_btu_h": 2115,
      "total_peak_heating_load_btu_h": 34252,
      "summer_conduction_gain_btu_h": 10782,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 577,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 21025,
      "total_cooling_latent_load_btu_h": 1862,
      "total_cooling_peak_load_btu_h": 22887,
      "calculated_cooling_tonnage": 1.91,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 277,
      "sensible_heat_ratio_shr": 0.919,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0244",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 21531,
      "heating_infiltration_loss_btu_h": 5548,
      "total_peak_heating_load_btu_h": 27079,
      "summer_conduction_gain_btu_h": 6553,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1513,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 18718,
      "total_cooling_latent_load_btu_h": 2860,
      "total_cooling_peak_load_btu_h": 21578,
      "calculated_cooling_tonnage": 1.8,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 66.7,
      "sensible_heat_ratio_shr": 0.867,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0245",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 33101,
      "heating_infiltration_loss_btu_h": 9825,
      "total_peak_heating_load_btu_h": 42926,
      "summer_conduction_gain_btu_h": 10009,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 2679,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 28089,
      "total_cooling_latent_load_btu_h": 4803,
      "total_cooling_peak_load_btu_h": 32892,
      "calculated_cooling_tonnage": 2.74,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 82.5,
      "sensible_heat_ratio_shr": 0.854,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0246",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 46109,
      "heating_infiltration_loss_btu_h": 14981,
      "total_peak_heating_load_btu_h": 61090,
      "summer_conduction_gain_btu_h": 13853,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 4086,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 38837,
      "total_cooling_latent_load_btu_h": 7103,
      "total_cooling_peak_load_btu_h": 45940,
      "calculated_cooling_tonnage": 3.83,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 88,
      "sensible_heat_ratio_shr": 0.845,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0247",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 21531,
      "heating_infiltration_loss_btu_h": 2287,
      "total_peak_heating_load_btu_h": 23818,
      "summer_conduction_gain_btu_h": 6553,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 624,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17829,
      "total_cooling_latent_load_btu_h": 1532,
      "total_cooling_peak_load_btu_h": 19361,
      "calculated_cooling_tonnage": 1.61,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 86.3,
      "sensible_heat_ratio_shr": 0.921,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0248",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 33101,
      "heating_infiltration_loss_btu_h": 4045,
      "total_peak_heating_load_btu_h": 37146,
      "summer_conduction_gain_btu_h": 10009,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1103,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 26513,
      "total_cooling_latent_load_btu_h": 2448,
      "total_cooling_peak_load_btu_h": 28961,
      "calculated_cooling_tonnage": 2.41,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 107.5,
      "sensible_heat_ratio_shr": 0.915,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0249",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 46109,
      "heating_infiltration_loss_btu_h": 6166,
      "total_peak_heating_load_btu_h": 52275,
      "summer_conduction_gain_btu_h": 13853,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 1682,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 36433,
      "total_cooling_latent_load_btu_h": 3512,
      "total_cooling_peak_load_btu_h": 39945,
      "calculated_cooling_tonnage": 3.33,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 116.2,
      "sensible_heat_ratio_shr": 0.912,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0250",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 21531,
      "heating_infiltration_loss_btu_h": 784,
      "total_peak_heating_load_btu_h": 22315,
      "summer_conduction_gain_btu_h": 6553,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 214,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17419,
      "total_cooling_latent_load_btu_h": 919,
      "total_cooling_peak_load_btu_h": 18338,
      "calculated_cooling_tonnage": 1.53,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 96.1,
      "sensible_heat_ratio_shr": 0.95,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0251",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 33101,
      "heating_infiltration_loss_btu_h": 1390,
      "total_peak_heating_load_btu_h": 34491,
      "summer_conduction_gain_btu_h": 10009,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 379,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 25789,
      "total_cooling_latent_load_btu_h": 1366,
      "total_cooling_peak_load_btu_h": 27155,
      "calculated_cooling_tonnage": 2.26,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 121.2,
      "sensible_heat_ratio_shr": 0.95,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0252",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 46109,
      "heating_infiltration_loss_btu_h": 2115,
      "total_peak_heating_load_btu_h": 48224,
      "summer_conduction_gain_btu_h": 13853,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 577,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 35328,
      "total_cooling_latent_load_btu_h": 1862,
      "total_cooling_peak_load_btu_h": 37190,
      "calculated_cooling_tonnage": 3.1,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 132.3,
      "sensible_heat_ratio_shr": 0.95,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0253",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 14947,
      "heating_infiltration_loss_btu_h": 5548,
      "total_peak_heating_load_btu_h": 20495,
      "summer_conduction_gain_btu_h": 4757,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1513,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15394,
      "total_cooling_latent_load_btu_h": 2860,
      "total_cooling_peak_load_btu_h": 18254,
      "calculated_cooling_tonnage": 1.52,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 97.4,
      "sensible_heat_ratio_shr": 0.843,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0254",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 23069,
      "heating_infiltration_loss_btu_h": 9825,
      "total_peak_heating_load_btu_h": 32894,
      "summer_conduction_gain_btu_h": 7273,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 2679,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 23023,
      "total_cooling_latent_load_btu_h": 4803,
      "total_cooling_peak_load_btu_h": 27826,
      "calculated_cooling_tonnage": 2.32,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 115.5,
      "sensible_heat_ratio_shr": 0.827,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0255",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 32002,
      "heating_infiltration_loss_btu_h": 14981,
      "total_peak_heating_load_btu_h": 46983,
      "summer_conduction_gain_btu_h": 10006,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 4086,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 31714,
      "total_cooling_latent_load_btu_h": 7103,
      "total_cooling_peak_load_btu_h": 38817,
      "calculated_cooling_tonnage": 3.23,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 122.9,
      "sensible_heat_ratio_shr": 0.817,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0256",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 14947,
      "heating_infiltration_loss_btu_h": 2287,
      "total_peak_heating_load_btu_h": 17234,
      "summer_conduction_gain_btu_h": 4757,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 624,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14505,
      "total_cooling_latent_load_btu_h": 1532,
      "total_cooling_peak_load_btu_h": 16037,
      "calculated_cooling_tonnage": 1.34,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 123.9,
      "sensible_heat_ratio_shr": 0.904,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0257",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 23069,
      "heating_infiltration_loss_btu_h": 4045,
      "total_peak_heating_load_btu_h": 27114,
      "summer_conduction_gain_btu_h": 7273,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1103,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 21447,
      "total_cooling_latent_load_btu_h": 2448,
      "total_cooling_peak_load_btu_h": 23895,
      "calculated_cooling_tonnage": 1.99,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 151.3,
      "sensible_heat_ratio_shr": 0.898,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0258",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 32002,
      "heating_infiltration_loss_btu_h": 6166,
      "total_peak_heating_load_btu_h": 38168,
      "summer_conduction_gain_btu_h": 10006,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 1682,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 29310,
      "total_cooling_latent_load_btu_h": 3512,
      "total_cooling_peak_load_btu_h": 32822,
      "calculated_cooling_tonnage": 2.74,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 162.8,
      "sensible_heat_ratio_shr": 0.893,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0259",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 14947,
      "heating_infiltration_loss_btu_h": 784,
      "total_peak_heating_load_btu_h": 15731,
      "summer_conduction_gain_btu_h": 4757,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 214,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14095,
      "total_cooling_latent_load_btu_h": 919,
      "total_cooling_peak_load_btu_h": 15014,
      "calculated_cooling_tonnage": 1.25,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 140,
      "sensible_heat_ratio_shr": 0.939,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0260",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 23069,
      "heating_infiltration_loss_btu_h": 1390,
      "total_peak_heating_load_btu_h": 24459,
      "summer_conduction_gain_btu_h": 7273,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 379,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 20723,
      "total_cooling_latent_load_btu_h": 1366,
      "total_cooling_peak_load_btu_h": 22089,
      "calculated_cooling_tonnage": 1.84,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 171.7,
      "sensible_heat_ratio_shr": 0.938,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0261",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 32002,
      "heating_infiltration_loss_btu_h": 2115,
      "total_peak_heating_load_btu_h": 34117,
      "summer_conduction_gain_btu_h": 10006,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 577,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 28205,
      "total_cooling_latent_load_btu_h": 1862,
      "total_cooling_peak_load_btu_h": 30067,
      "calculated_cooling_tonnage": 2.51,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 186.9,
      "sensible_heat_ratio_shr": 0.938,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0262",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 12637,
      "heating_infiltration_loss_btu_h": 5548,
      "total_peak_heating_load_btu_h": 18185,
      "summer_conduction_gain_btu_h": 4127,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1513,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 11051,
      "total_cooling_latent_load_btu_h": 2860,
      "total_cooling_peak_load_btu_h": 13911,
      "calculated_cooling_tonnage": 1.16,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 158.6,
      "sensible_heat_ratio_shr": 0.794,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0263",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 19549,
      "heating_infiltration_loss_btu_h": 9825,
      "total_peak_heating_load_btu_h": 29374,
      "summer_conduction_gain_btu_h": 6313,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 2679,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 16406,
      "total_cooling_latent_load_btu_h": 4803,
      "total_cooling_peak_load_btu_h": 21209,
      "calculated_cooling_tonnage": 1.77,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 182.5,
      "sensible_heat_ratio_shr": 0.774,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0264",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 27052,
      "heating_infiltration_loss_btu_h": 14981,
      "total_peak_heating_load_btu_h": 42033,
      "summer_conduction_gain_btu_h": 8656,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 4086,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 22408,
      "total_cooling_latent_load_btu_h": 7103,
      "total_cooling_peak_load_btu_h": 29511,
      "calculated_cooling_tonnage": 2.46,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 192.7,
      "sensible_heat_ratio_shr": 0.759,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0265",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 12637,
      "heating_infiltration_loss_btu_h": 2287,
      "total_peak_heating_load_btu_h": 14924,
      "summer_conduction_gain_btu_h": 4127,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 624,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10162,
      "total_cooling_latent_load_btu_h": 1532,
      "total_cooling_peak_load_btu_h": 11694,
      "calculated_cooling_tonnage": 0.97,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 209.3,
      "sensible_heat_ratio_shr": 0.869,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0266",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 19549,
      "heating_infiltration_loss_btu_h": 4045,
      "total_peak_heating_load_btu_h": 23594,
      "summer_conduction_gain_btu_h": 6313,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1103,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 14830,
      "total_cooling_latent_load_btu_h": 2448,
      "total_cooling_peak_load_btu_h": 17278,
      "calculated_cooling_tonnage": 1.44,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 247.2,
      "sensible_heat_ratio_shr": 0.858,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0267",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 27052,
      "heating_infiltration_loss_btu_h": 6166,
      "total_peak_heating_load_btu_h": 33218,
      "summer_conduction_gain_btu_h": 8656,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 1682,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 20004,
      "total_cooling_latent_load_btu_h": 3512,
      "total_cooling_peak_load_btu_h": 23516,
      "calculated_cooling_tonnage": 1.96,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 267.3,
      "sensible_heat_ratio_shr": 0.851,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0268",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 12637,
      "heating_infiltration_loss_btu_h": 784,
      "total_peak_heating_load_btu_h": 13421,
      "summer_conduction_gain_btu_h": 4127,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 214,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9752,
      "total_cooling_latent_load_btu_h": 919,
      "total_cooling_peak_load_btu_h": 10671,
      "calculated_cooling_tonnage": 0.89,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 237.1,
      "sensible_heat_ratio_shr": 0.914,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0269",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 19549,
      "heating_infiltration_loss_btu_h": 1390,
      "total_peak_heating_load_btu_h": 20939,
      "summer_conduction_gain_btu_h": 6313,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 379,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 14106,
      "total_cooling_latent_load_btu_h": 1366,
      "total_cooling_peak_load_btu_h": 15472,
      "calculated_cooling_tonnage": 1.29,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 287.6,
      "sensible_heat_ratio_shr": 0.912,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0270",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 27052,
      "heating_infiltration_loss_btu_h": 2115,
      "total_peak_heating_load_btu_h": 29167,
      "summer_conduction_gain_btu_h": 8656,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 577,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 18899,
      "total_cooling_latent_load_btu_h": 1862,
      "total_cooling_peak_load_btu_h": 20761,
      "calculated_cooling_tonnage": 1.73,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 316.2,
      "sensible_heat_ratio_shr": 0.91,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0271",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 20811,
      "heating_infiltration_loss_btu_h": 5548,
      "total_peak_heating_load_btu_h": 26359,
      "summer_conduction_gain_btu_h": 6252,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1513,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 18417,
      "total_cooling_latent_load_btu_h": 2860,
      "total_cooling_peak_load_btu_h": 21277,
      "calculated_cooling_tonnage": 1.77,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 69.5,
      "sensible_heat_ratio_shr": 0.866,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0272",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 32085,
      "heating_infiltration_loss_btu_h": 9825,
      "total_peak_heating_load_btu_h": 41910,
      "summer_conduction_gain_btu_h": 9584,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 2679,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 27664,
      "total_cooling_latent_load_btu_h": 4803,
      "total_cooling_peak_load_btu_h": 32467,
      "calculated_cooling_tonnage": 2.71,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 84.5,
      "sensible_heat_ratio_shr": 0.852,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0273",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 44809,
      "heating_infiltration_loss_btu_h": 14981,
      "total_peak_heating_load_btu_h": 59790,
      "summer_conduction_gain_btu_h": 13309,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 4086,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 38293,
      "total_cooling_latent_load_btu_h": 7103,
      "total_cooling_peak_load_btu_h": 45396,
      "calculated_cooling_tonnage": 3.78,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 90.5,
      "sensible_heat_ratio_shr": 0.844,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0274",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 20811,
      "heating_infiltration_loss_btu_h": 2287,
      "total_peak_heating_load_btu_h": 23098,
      "summer_conduction_gain_btu_h": 6252,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 624,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17528,
      "total_cooling_latent_load_btu_h": 1532,
      "total_cooling_peak_load_btu_h": 19060,
      "calculated_cooling_tonnage": 1.59,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 88.7,
      "sensible_heat_ratio_shr": 0.92,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0275",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 32085,
      "heating_infiltration_loss_btu_h": 4045,
      "total_peak_heating_load_btu_h": 36130,
      "summer_conduction_gain_btu_h": 9584,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1103,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 26088,
      "total_cooling_latent_load_btu_h": 2448,
      "total_cooling_peak_load_btu_h": 28536,
      "calculated_cooling_tonnage": 2.38,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 110.1,
      "sensible_heat_ratio_shr": 0.914,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0276",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 44809,
      "heating_infiltration_loss_btu_h": 6166,
      "total_peak_heating_load_btu_h": 50975,
      "summer_conduction_gain_btu_h": 13309,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 1682,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 35889,
      "total_cooling_latent_load_btu_h": 3512,
      "total_cooling_peak_load_btu_h": 39401,
      "calculated_cooling_tonnage": 3.28,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 119.5,
      "sensible_heat_ratio_shr": 0.911,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0277",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 20811,
      "heating_infiltration_loss_btu_h": 784,
      "total_peak_heating_load_btu_h": 21595,
      "summer_conduction_gain_btu_h": 6252,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 214,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17118,
      "total_cooling_latent_load_btu_h": 919,
      "total_cooling_peak_load_btu_h": 18037,
      "calculated_cooling_tonnage": 1.5,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 100,
      "sensible_heat_ratio_shr": 0.949,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0278",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 32085,
      "heating_infiltration_loss_btu_h": 1390,
      "total_peak_heating_load_btu_h": 33475,
      "summer_conduction_gain_btu_h": 9584,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 379,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 25364,
      "total_cooling_latent_load_btu_h": 1366,
      "total_cooling_peak_load_btu_h": 26730,
      "calculated_cooling_tonnage": 2.23,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 124.2,
      "sensible_heat_ratio_shr": 0.949,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0279",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 44809,
      "heating_infiltration_loss_btu_h": 2115,
      "total_peak_heating_load_btu_h": 46924,
      "summer_conduction_gain_btu_h": 13309,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 577,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 34784,
      "total_cooling_latent_load_btu_h": 1862,
      "total_cooling_peak_load_btu_h": 36646,
      "calculated_cooling_tonnage": 3.05,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 136.1,
      "sensible_heat_ratio_shr": 0.949,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0280",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 14227,
      "heating_infiltration_loss_btu_h": 5548,
      "total_peak_heating_load_btu_h": 19775,
      "summer_conduction_gain_btu_h": 4456,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1513,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15093,
      "total_cooling_latent_load_btu_h": 2860,
      "total_cooling_peak_load_btu_h": 17953,
      "calculated_cooling_tonnage": 1.5,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 100,
      "sensible_heat_ratio_shr": 0.841,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0281",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 22053,
      "heating_infiltration_loss_btu_h": 9825,
      "total_peak_heating_load_btu_h": 31878,
      "summer_conduction_gain_btu_h": 6848,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 2679,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 22598,
      "total_cooling_latent_load_btu_h": 4803,
      "total_cooling_peak_load_btu_h": 27401,
      "calculated_cooling_tonnage": 2.28,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 119.3,
      "sensible_heat_ratio_shr": 0.825,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0282",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 30701,
      "heating_infiltration_loss_btu_h": 14981,
      "total_peak_heating_load_btu_h": 45682,
      "summer_conduction_gain_btu_h": 9462,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 4086,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 31170,
      "total_cooling_latent_load_btu_h": 7103,
      "total_cooling_peak_load_btu_h": 38273,
      "calculated_cooling_tonnage": 3.19,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 125.7,
      "sensible_heat_ratio_shr": 0.814,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0283",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 14227,
      "heating_infiltration_loss_btu_h": 2287,
      "total_peak_heating_load_btu_h": 16514,
      "summer_conduction_gain_btu_h": 4456,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 624,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14204,
      "total_cooling_latent_load_btu_h": 1532,
      "total_cooling_peak_load_btu_h": 15736,
      "calculated_cooling_tonnage": 1.31,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 129,
      "sensible_heat_ratio_shr": 0.903,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0284",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 22053,
      "heating_infiltration_loss_btu_h": 4045,
      "total_peak_heating_load_btu_h": 26098,
      "summer_conduction_gain_btu_h": 6848,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1103,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 21022,
      "total_cooling_latent_load_btu_h": 2448,
      "total_cooling_peak_load_btu_h": 23470,
      "calculated_cooling_tonnage": 1.96,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 155.1,
      "sensible_heat_ratio_shr": 0.896,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0285",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 30701,
      "heating_infiltration_loss_btu_h": 6166,
      "total_peak_heating_load_btu_h": 36867,
      "summer_conduction_gain_btu_h": 9462,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 1682,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 28766,
      "total_cooling_latent_load_btu_h": 3512,
      "total_cooling_peak_load_btu_h": 32278,
      "calculated_cooling_tonnage": 2.69,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 167.7,
      "sensible_heat_ratio_shr": 0.891,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0286",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 14227,
      "heating_infiltration_loss_btu_h": 784,
      "total_peak_heating_load_btu_h": 15011,
      "summer_conduction_gain_btu_h": 4456,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 214,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13794,
      "total_cooling_latent_load_btu_h": 919,
      "total_cooling_peak_load_btu_h": 14713,
      "calculated_cooling_tonnage": 1.23,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 143.9,
      "sensible_heat_ratio_shr": 0.938,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0287",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 22053,
      "heating_infiltration_loss_btu_h": 1390,
      "total_peak_heating_load_btu_h": 23443,
      "summer_conduction_gain_btu_h": 6848,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 379,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 20298,
      "total_cooling_latent_load_btu_h": 1366,
      "total_cooling_peak_load_btu_h": 21664,
      "calculated_cooling_tonnage": 1.81,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 176.2,
      "sensible_heat_ratio_shr": 0.937,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0288",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 30701,
      "heating_infiltration_loss_btu_h": 2115,
      "total_peak_heating_load_btu_h": 32816,
      "summer_conduction_gain_btu_h": 9462,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 577,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 27661,
      "total_cooling_latent_load_btu_h": 1862,
      "total_cooling_peak_load_btu_h": 29523,
      "calculated_cooling_tonnage": 2.46,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 192.7,
      "sensible_heat_ratio_shr": 0.937,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0289",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 11917,
      "heating_infiltration_loss_btu_h": 5548,
      "total_peak_heating_load_btu_h": 17465,
      "summer_conduction_gain_btu_h": 3826,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1513,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10750,
      "total_cooling_latent_load_btu_h": 2860,
      "total_cooling_peak_load_btu_h": 13610,
      "calculated_cooling_tonnage": 1.13,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 165.5,
      "sensible_heat_ratio_shr": 0.79,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0290",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 18533,
      "heating_infiltration_loss_btu_h": 9825,
      "total_peak_heating_load_btu_h": 28358,
      "summer_conduction_gain_btu_h": 5888,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 2679,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 15981,
      "total_cooling_latent_load_btu_h": 4803,
      "total_cooling_peak_load_btu_h": 20784,
      "calculated_cooling_tonnage": 1.73,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 189,
      "sensible_heat_ratio_shr": 0.769,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0291",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 25751,
      "heating_infiltration_loss_btu_h": 14981,
      "total_peak_heating_load_btu_h": 40732,
      "summer_conduction_gain_btu_h": 8112,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 4086,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 21864,
      "total_cooling_latent_load_btu_h": 7103,
      "total_cooling_peak_load_btu_h": 28967,
      "calculated_cooling_tonnage": 2.41,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 198.8,
      "sensible_heat_ratio_shr": 0.755,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0292",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 11917,
      "heating_infiltration_loss_btu_h": 2287,
      "total_peak_heating_load_btu_h": 14204,
      "summer_conduction_gain_btu_h": 3826,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 624,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9861,
      "total_cooling_latent_load_btu_h": 1532,
      "total_cooling_peak_load_btu_h": 11393,
      "calculated_cooling_tonnage": 0.95,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 215.8,
      "sensible_heat_ratio_shr": 0.866,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0293",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 18533,
      "heating_infiltration_loss_btu_h": 4045,
      "total_peak_heating_load_btu_h": 22578,
      "summer_conduction_gain_btu_h": 5888,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1103,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 14405,
      "total_cooling_latent_load_btu_h": 2448,
      "total_cooling_peak_load_btu_h": 16853,
      "calculated_cooling_tonnage": 1.4,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 257.1,
      "sensible_heat_ratio_shr": 0.855,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0294",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 25751,
      "heating_infiltration_loss_btu_h": 6166,
      "total_peak_heating_load_btu_h": 31917,
      "summer_conduction_gain_btu_h": 8112,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 1682,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 19460,
      "total_cooling_latent_load_btu_h": 3512,
      "total_cooling_peak_load_btu_h": 22972,
      "calculated_cooling_tonnage": 1.91,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 277,
      "sensible_heat_ratio_shr": 0.847,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0295",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 11917,
      "heating_infiltration_loss_btu_h": 784,
      "total_peak_heating_load_btu_h": 12701,
      "summer_conduction_gain_btu_h": 3826,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 214,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9451,
      "total_cooling_latent_load_btu_h": 919,
      "total_cooling_peak_load_btu_h": 10370,
      "calculated_cooling_tonnage": 0.86,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 248.8,
      "sensible_heat_ratio_shr": 0.911,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0296",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 18533,
      "heating_infiltration_loss_btu_h": 1390,
      "total_peak_heating_load_btu_h": 19923,
      "summer_conduction_gain_btu_h": 5888,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 379,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 13681,
      "total_cooling_latent_load_btu_h": 1366,
      "total_cooling_peak_load_btu_h": 15047,
      "calculated_cooling_tonnage": 1.25,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 300,
      "sensible_heat_ratio_shr": 0.909,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0297",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 25751,
      "heating_infiltration_loss_btu_h": 2115,
      "total_peak_heating_load_btu_h": 27866,
      "summer_conduction_gain_btu_h": 8112,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 577,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 18355,
      "total_cooling_latent_load_btu_h": 1862,
      "total_cooling_peak_load_btu_h": 20217,
      "calculated_cooling_tonnage": 1.68,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 328.6,
      "sensible_heat_ratio_shr": 0.908,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0298",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 20026,
      "heating_infiltration_loss_btu_h": 5548,
      "total_peak_heating_load_btu_h": 25574,
      "summer_conduction_gain_btu_h": 5923,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1513,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 18088,
      "total_cooling_latent_load_btu_h": 2860,
      "total_cooling_peak_load_btu_h": 20948,
      "calculated_cooling_tonnage": 1.75,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 71.4,
      "sensible_heat_ratio_shr": 0.863,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0299",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 30976,
      "heating_infiltration_loss_btu_h": 9825,
      "total_peak_heating_load_btu_h": 40801,
      "summer_conduction_gain_btu_h": 9121,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 2679,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 27201,
      "total_cooling_latent_load_btu_h": 4803,
      "total_cooling_peak_load_btu_h": 32004,
      "calculated_cooling_tonnage": 2.67,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 87.3,
      "sensible_heat_ratio_shr": 0.85,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0300",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 43390,
      "heating_infiltration_loss_btu_h": 14981,
      "total_peak_heating_load_btu_h": 58371,
      "summer_conduction_gain_btu_h": 12716,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 4086,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 37700,
      "total_cooling_latent_load_btu_h": 7103,
      "total_cooling_peak_load_btu_h": 44803,
      "calculated_cooling_tonnage": 3.73,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 93,
      "sensible_heat_ratio_shr": 0.841,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0301",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 20026,
      "heating_infiltration_loss_btu_h": 2287,
      "total_peak_heating_load_btu_h": 22313,
      "summer_conduction_gain_btu_h": 5923,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 624,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17199,
      "total_cooling_latent_load_btu_h": 1532,
      "total_cooling_peak_load_btu_h": 18731,
      "calculated_cooling_tonnage": 1.56,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 92.3,
      "sensible_heat_ratio_shr": 0.918,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0302",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 30976,
      "heating_infiltration_loss_btu_h": 4045,
      "total_peak_heating_load_btu_h": 35021,
      "summer_conduction_gain_btu_h": 9121,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1103,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 25625,
      "total_cooling_latent_load_btu_h": 2448,
      "total_cooling_peak_load_btu_h": 28073,
      "calculated_cooling_tonnage": 2.34,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 113.7,
      "sensible_heat_ratio_shr": 0.913,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0303",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 43390,
      "heating_infiltration_loss_btu_h": 6166,
      "total_peak_heating_load_btu_h": 49556,
      "summer_conduction_gain_btu_h": 12716,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 1682,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 35296,
      "total_cooling_latent_load_btu_h": 3512,
      "total_cooling_peak_load_btu_h": 38808,
      "calculated_cooling_tonnage": 3.23,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 122.9,
      "sensible_heat_ratio_shr": 0.91,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0304",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 20026,
      "heating_infiltration_loss_btu_h": 784,
      "total_peak_heating_load_btu_h": 20810,
      "summer_conduction_gain_btu_h": 5923,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 214,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16789,
      "total_cooling_latent_load_btu_h": 919,
      "total_cooling_peak_load_btu_h": 17708,
      "calculated_cooling_tonnage": 1.48,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 102.7,
      "sensible_heat_ratio_shr": 0.948,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0305",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 30976,
      "heating_infiltration_loss_btu_h": 1390,
      "total_peak_heating_load_btu_h": 32366,
      "summer_conduction_gain_btu_h": 9121,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 379,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 24901,
      "total_cooling_latent_load_btu_h": 1366,
      "total_cooling_peak_load_btu_h": 26267,
      "calculated_cooling_tonnage": 2.19,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 128.3,
      "sensible_heat_ratio_shr": 0.948,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0306",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 43390,
      "heating_infiltration_loss_btu_h": 2115,
      "total_peak_heating_load_btu_h": 45505,
      "summer_conduction_gain_btu_h": 12716,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 577,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 34191,
      "total_cooling_latent_load_btu_h": 1862,
      "total_cooling_peak_load_btu_h": 36053,
      "calculated_cooling_tonnage": 3,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 140,
      "sensible_heat_ratio_shr": 0.948,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0307",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 13442,
      "heating_infiltration_loss_btu_h": 5548,
      "total_peak_heating_load_btu_h": 18990,
      "summer_conduction_gain_btu_h": 4128,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1513,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14765,
      "total_cooling_latent_load_btu_h": 2860,
      "total_cooling_peak_load_btu_h": 17625,
      "calculated_cooling_tonnage": 1.47,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 104.1,
      "sensible_heat_ratio_shr": 0.838,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0308",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 20944,
      "heating_infiltration_loss_btu_h": 9825,
      "total_peak_heating_load_btu_h": 30769,
      "summer_conduction_gain_btu_h": 6385,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 2679,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 22135,
      "total_cooling_latent_load_btu_h": 4803,
      "total_cooling_peak_load_btu_h": 26938,
      "calculated_cooling_tonnage": 2.24,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 123.2,
      "sensible_heat_ratio_shr": 0.822,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0309",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 29282,
      "heating_infiltration_loss_btu_h": 14981,
      "total_peak_heating_load_btu_h": 44263,
      "summer_conduction_gain_btu_h": 8868,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 4086,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 30576,
      "total_cooling_latent_load_btu_h": 7103,
      "total_cooling_peak_load_btu_h": 37679,
      "calculated_cooling_tonnage": 3.14,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 129.3,
      "sensible_heat_ratio_shr": 0.811,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0310",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 13442,
      "heating_infiltration_loss_btu_h": 2287,
      "total_peak_heating_load_btu_h": 15729,
      "summer_conduction_gain_btu_h": 4128,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 624,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13876,
      "total_cooling_latent_load_btu_h": 1532,
      "total_cooling_peak_load_btu_h": 15408,
      "calculated_cooling_tonnage": 1.28,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 134.4,
      "sensible_heat_ratio_shr": 0.901,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0311",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 20944,
      "heating_infiltration_loss_btu_h": 4045,
      "total_peak_heating_load_btu_h": 24989,
      "summer_conduction_gain_btu_h": 6385,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1103,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 20559,
      "total_cooling_latent_load_btu_h": 2448,
      "total_cooling_peak_load_btu_h": 23007,
      "calculated_cooling_tonnage": 1.92,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 160.4,
      "sensible_heat_ratio_shr": 0.894,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0312",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 29282,
      "heating_infiltration_loss_btu_h": 6166,
      "total_peak_heating_load_btu_h": 35448,
      "summer_conduction_gain_btu_h": 8868,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 1682,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 28172,
      "total_cooling_latent_load_btu_h": 3512,
      "total_cooling_peak_load_btu_h": 31684,
      "calculated_cooling_tonnage": 2.64,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 172.7,
      "sensible_heat_ratio_shr": 0.889,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0313",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 13442,
      "heating_infiltration_loss_btu_h": 784,
      "total_peak_heating_load_btu_h": 14226,
      "summer_conduction_gain_btu_h": 4128,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 214,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13466,
      "total_cooling_latent_load_btu_h": 919,
      "total_cooling_peak_load_btu_h": 14385,
      "calculated_cooling_tonnage": 1.2,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 150,
      "sensible_heat_ratio_shr": 0.936,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0314",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 20944,
      "heating_infiltration_loss_btu_h": 1390,
      "total_peak_heating_load_btu_h": 22334,
      "summer_conduction_gain_btu_h": 6385,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 379,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 19835,
      "total_cooling_latent_load_btu_h": 1366,
      "total_cooling_peak_load_btu_h": 21201,
      "calculated_cooling_tonnage": 1.77,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 182.5,
      "sensible_heat_ratio_shr": 0.936,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0315",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 29282,
      "heating_infiltration_loss_btu_h": 2115,
      "total_peak_heating_load_btu_h": 31397,
      "summer_conduction_gain_btu_h": 8868,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 577,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 27067,
      "total_cooling_latent_load_btu_h": 1862,
      "total_cooling_peak_load_btu_h": 28929,
      "calculated_cooling_tonnage": 2.41,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 198.8,
      "sensible_heat_ratio_shr": 0.936,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0316",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 11132,
      "heating_infiltration_loss_btu_h": 5548,
      "total_peak_heating_load_btu_h": 16680,
      "summer_conduction_gain_btu_h": 3498,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1513,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10422,
      "total_cooling_latent_load_btu_h": 2860,
      "total_cooling_peak_load_btu_h": 13282,
      "calculated_cooling_tonnage": 1.11,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 170.3,
      "sensible_heat_ratio_shr": 0.785,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0317",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 17424,
      "heating_infiltration_loss_btu_h": 9825,
      "total_peak_heating_load_btu_h": 27249,
      "summer_conduction_gain_btu_h": 5425,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 2679,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 15518,
      "total_cooling_latent_load_btu_h": 4803,
      "total_cooling_peak_load_btu_h": 20321,
      "calculated_cooling_tonnage": 1.69,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 195.9,
      "sensible_heat_ratio_shr": 0.764,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0318",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 24332,
      "heating_infiltration_loss_btu_h": 14981,
      "total_peak_heating_load_btu_h": 39313,
      "summer_conduction_gain_btu_h": 7518,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 4086,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 21270,
      "total_cooling_latent_load_btu_h": 7103,
      "total_cooling_peak_load_btu_h": 28373,
      "calculated_cooling_tonnage": 2.36,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 205.1,
      "sensible_heat_ratio_shr": 0.75,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0319",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 11132,
      "heating_infiltration_loss_btu_h": 2287,
      "total_peak_heating_load_btu_h": 13419,
      "summer_conduction_gain_btu_h": 3498,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 624,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9533,
      "total_cooling_latent_load_btu_h": 1532,
      "total_cooling_peak_load_btu_h": 11065,
      "calculated_cooling_tonnage": 0.92,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 226.1,
      "sensible_heat_ratio_shr": 0.862,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0320",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 17424,
      "heating_infiltration_loss_btu_h": 4045,
      "total_peak_heating_load_btu_h": 21469,
      "summer_conduction_gain_btu_h": 5425,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1103,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 13942,
      "total_cooling_latent_load_btu_h": 2448,
      "total_cooling_peak_load_btu_h": 16390,
      "calculated_cooling_tonnage": 1.37,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 265,
      "sensible_heat_ratio_shr": 0.851,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0321",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 24332,
      "heating_infiltration_loss_btu_h": 6166,
      "total_peak_heating_load_btu_h": 30498,
      "summer_conduction_gain_btu_h": 7518,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 1682,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 18866,
      "total_cooling_latent_load_btu_h": 3512,
      "total_cooling_peak_load_btu_h": 22378,
      "calculated_cooling_tonnage": 1.86,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 287.1,
      "sensible_heat_ratio_shr": 0.843,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0322",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 11132,
      "heating_infiltration_loss_btu_h": 784,
      "total_peak_heating_load_btu_h": 11916,
      "summer_conduction_gain_btu_h": 3498,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 214,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9123,
      "total_cooling_latent_load_btu_h": 919,
      "total_cooling_peak_load_btu_h": 10042,
      "calculated_cooling_tonnage": 0.84,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 257.1,
      "sensible_heat_ratio_shr": 0.908,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0323",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 17424,
      "heating_infiltration_loss_btu_h": 1390,
      "total_peak_heating_load_btu_h": 18814,
      "summer_conduction_gain_btu_h": 5425,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 379,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 13218,
      "total_cooling_latent_load_btu_h": 1366,
      "total_cooling_peak_load_btu_h": 14584,
      "calculated_cooling_tonnage": 1.22,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 309.8,
      "sensible_heat_ratio_shr": 0.906,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0324",
      "climate_zone": "CZ-4",
      "climate_zone_name": "Mixed (DC/St. Louis)",
      "outdoor_winter_db_f": 15,
      "outdoor_summer_db_f": 90,
      "outdoor_summer_wb_f": 74,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 24332,
      "heating_infiltration_loss_btu_h": 2115,
      "total_peak_heating_load_btu_h": 26447,
      "summer_conduction_gain_btu_h": 7518,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 577,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 17761,
      "total_cooling_latent_load_btu_h": 1862,
      "total_cooling_peak_load_btu_h": 19623,
      "calculated_cooling_tonnage": 1.64,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 339,
      "sensible_heat_ratio_shr": 0.905,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0325",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 30355,
      "heating_infiltration_loss_btu_h": 7061,
      "total_peak_heating_load_btu_h": 37416,
      "summer_conduction_gain_btu_h": 6625,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1311,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 18588,
      "total_cooling_latent_load_btu_h": 2182,
      "total_cooling_peak_load_btu_h": 20770,
      "calculated_cooling_tonnage": 1.73,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 73.4,
      "sensible_heat_ratio_shr": 0.895,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0326",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 46136,
      "heating_infiltration_loss_btu_h": 12504,
      "total_peak_heating_load_btu_h": 58640,
      "summer_conduction_gain_btu_h": 9958,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 2322,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 27681,
      "total_cooling_latent_load_btu_h": 3602,
      "total_cooling_peak_load_btu_h": 31283,
      "calculated_cooling_tonnage": 2.61,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 91.6,
      "sensible_heat_ratio_shr": 0.885,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0327",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 63644,
      "heating_infiltration_loss_btu_h": 19066,
      "total_peak_heating_load_btu_h": 82710,
      "summer_conduction_gain_btu_h": 13592,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 3541,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 38031,
      "total_cooling_latent_load_btu_h": 5272,
      "total_cooling_peak_load_btu_h": 43303,
      "calculated_cooling_tonnage": 3.61,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 99.4,
      "sensible_heat_ratio_shr": 0.878,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0328",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 30355,
      "heating_infiltration_loss_btu_h": 2911,
      "total_peak_heating_load_btu_h": 33266,
      "summer_conduction_gain_btu_h": 6625,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 541,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17818,
      "total_cooling_latent_load_btu_h": 1252,
      "total_cooling_peak_load_btu_h": 19070,
      "calculated_cooling_tonnage": 1.59,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 88.7,
      "sensible_heat_ratio_shr": 0.934,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0329",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 46136,
      "heating_infiltration_loss_btu_h": 5148,
      "total_peak_heating_load_btu_h": 51284,
      "summer_conduction_gain_btu_h": 9958,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 956,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 26315,
      "total_cooling_latent_load_btu_h": 1954,
      "total_cooling_peak_load_btu_h": 28269,
      "calculated_cooling_tonnage": 2.36,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 111.9,
      "sensible_heat_ratio_shr": 0.931,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0330",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 63644,
      "heating_infiltration_loss_btu_h": 7847,
      "total_peak_heating_load_btu_h": 71491,
      "summer_conduction_gain_btu_h": 13592,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 1457,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 35947,
      "total_cooling_latent_load_btu_h": 2758,
      "total_cooling_peak_load_btu_h": 38705,
      "calculated_cooling_tonnage": 3.23,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 122.9,
      "sensible_heat_ratio_shr": 0.929,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0331",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 30355,
      "heating_infiltration_loss_btu_h": 998,
      "total_peak_heating_load_btu_h": 31353,
      "summer_conduction_gain_btu_h": 6625,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 185,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17462,
      "total_cooling_latent_load_btu_h": 824,
      "total_cooling_peak_load_btu_h": 18286,
      "calculated_cooling_tonnage": 1.52,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 97.4,
      "sensible_heat_ratio_shr": 0.955,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0332",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 46136,
      "heating_infiltration_loss_btu_h": 1769,
      "total_peak_heating_load_btu_h": 47905,
      "summer_conduction_gain_btu_h": 9958,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 329,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 25688,
      "total_cooling_latent_load_btu_h": 1196,
      "total_cooling_peak_load_btu_h": 26884,
      "calculated_cooling_tonnage": 2.24,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 123.2,
      "sensible_heat_ratio_shr": 0.956,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0333",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 63644,
      "heating_infiltration_loss_btu_h": 2691,
      "total_peak_heating_load_btu_h": 66335,
      "summer_conduction_gain_btu_h": 13592,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 500,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 34990,
      "total_cooling_latent_load_btu_h": 1603,
      "total_cooling_peak_load_btu_h": 36593,
      "calculated_cooling_tonnage": 3.05,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 136.1,
      "sensible_heat_ratio_shr": 0.956,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0334",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 21976,
      "heating_infiltration_loss_btu_h": 7061,
      "total_peak_heating_load_btu_h": 29037,
      "summer_conduction_gain_btu_h": 5069,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1311,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15504,
      "total_cooling_latent_load_btu_h": 2182,
      "total_cooling_peak_load_btu_h": 17686,
      "calculated_cooling_tonnage": 1.47,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 104.1,
      "sensible_heat_ratio_shr": 0.877,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0335",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 33368,
      "heating_infiltration_loss_btu_h": 12504,
      "total_peak_heating_load_btu_h": 45872,
      "summer_conduction_gain_btu_h": 7586,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 2322,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 22979,
      "total_cooling_latent_load_btu_h": 3602,
      "total_cooling_peak_load_btu_h": 26581,
      "calculated_cooling_tonnage": 2.22,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 125.2,
      "sensible_heat_ratio_shr": 0.864,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0336",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 45689,
      "heating_infiltration_loss_btu_h": 19066,
      "total_peak_heating_load_btu_h": 64755,
      "summer_conduction_gain_btu_h": 10258,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 3541,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 31421,
      "total_cooling_latent_load_btu_h": 5272,
      "total_cooling_peak_load_btu_h": 36693,
      "calculated_cooling_tonnage": 3.06,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 135.3,
      "sensible_heat_ratio_shr": 0.856,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0337",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 21976,
      "heating_infiltration_loss_btu_h": 2911,
      "total_peak_heating_load_btu_h": 24887,
      "summer_conduction_gain_btu_h": 5069,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 541,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14734,
      "total_cooling_latent_load_btu_h": 1252,
      "total_cooling_peak_load_btu_h": 15986,
      "calculated_cooling_tonnage": 1.33,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 125.6,
      "sensible_heat_ratio_shr": 0.922,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0338",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 33368,
      "heating_infiltration_loss_btu_h": 5148,
      "total_peak_heating_load_btu_h": 38516,
      "summer_conduction_gain_btu_h": 7586,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 956,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 21613,
      "total_cooling_latent_load_btu_h": 1954,
      "total_cooling_peak_load_btu_h": 23567,
      "calculated_cooling_tonnage": 1.96,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 155.1,
      "sensible_heat_ratio_shr": 0.917,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0339",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 45689,
      "heating_infiltration_loss_btu_h": 7847,
      "total_peak_heating_load_btu_h": 53536,
      "summer_conduction_gain_btu_h": 10258,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 1457,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 29337,
      "total_cooling_latent_load_btu_h": 2758,
      "total_cooling_peak_load_btu_h": 32095,
      "calculated_cooling_tonnage": 2.67,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 169.7,
      "sensible_heat_ratio_shr": 0.914,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0340",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 21976,
      "heating_infiltration_loss_btu_h": 998,
      "total_peak_heating_load_btu_h": 22974,
      "summer_conduction_gain_btu_h": 5069,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 185,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14378,
      "total_cooling_latent_load_btu_h": 824,
      "total_cooling_peak_load_btu_h": 15202,
      "calculated_cooling_tonnage": 1.27,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 136.2,
      "sensible_heat_ratio_shr": 0.946,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0341",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 33368,
      "heating_infiltration_loss_btu_h": 1769,
      "total_peak_heating_load_btu_h": 35137,
      "summer_conduction_gain_btu_h": 7586,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 329,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 20986,
      "total_cooling_latent_load_btu_h": 1196,
      "total_cooling_peak_load_btu_h": 22182,
      "calculated_cooling_tonnage": 1.85,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 170.3,
      "sensible_heat_ratio_shr": 0.946,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0342",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 45689,
      "heating_infiltration_loss_btu_h": 2691,
      "total_peak_heating_load_btu_h": 48380,
      "summer_conduction_gain_btu_h": 10258,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 500,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 28380,
      "total_cooling_latent_load_btu_h": 1603,
      "total_cooling_peak_load_btu_h": 29983,
      "calculated_cooling_tonnage": 2.5,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 188,
      "sensible_heat_ratio_shr": 0.947,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0343",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 19036,
      "heating_infiltration_loss_btu_h": 7061,
      "total_peak_heating_load_btu_h": 26097,
      "summer_conduction_gain_btu_h": 4523,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1311,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 11245,
      "total_cooling_latent_load_btu_h": 2182,
      "total_cooling_peak_load_btu_h": 13427,
      "calculated_cooling_tonnage": 1.12,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 167.9,
      "sensible_heat_ratio_shr": 0.837,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0344",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 28888,
      "heating_infiltration_loss_btu_h": 12504,
      "total_peak_heating_load_btu_h": 41392,
      "summer_conduction_gain_btu_h": 6754,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 2322,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 16490,
      "total_cooling_latent_load_btu_h": 3602,
      "total_cooling_peak_load_btu_h": 20092,
      "calculated_cooling_tonnage": 1.67,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 199.4,
      "sensible_heat_ratio_shr": 0.821,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0345",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 39389,
      "heating_infiltration_loss_btu_h": 19066,
      "total_peak_heating_load_btu_h": 58455,
      "summer_conduction_gain_btu_h": 9088,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 3541,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 22295,
      "total_cooling_latent_load_btu_h": 5272,
      "total_cooling_peak_load_btu_h": 27567,
      "calculated_cooling_tonnage": 2.3,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 213,
      "sensible_heat_ratio_shr": 0.809,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0346",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 19036,
      "heating_infiltration_loss_btu_h": 2911,
      "total_peak_heating_load_btu_h": 21947,
      "summer_conduction_gain_btu_h": 4523,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 541,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10475,
      "total_cooling_latent_load_btu_h": 1252,
      "total_cooling_peak_load_btu_h": 11727,
      "calculated_cooling_tonnage": 0.98,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 206.1,
      "sensible_heat_ratio_shr": 0.893,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0347",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 28888,
      "heating_infiltration_loss_btu_h": 5148,
      "total_peak_heating_load_btu_h": 34036,
      "summer_conduction_gain_btu_h": 6754,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 956,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 15124,
      "total_cooling_latent_load_btu_h": 1954,
      "total_cooling_peak_load_btu_h": 17078,
      "calculated_cooling_tonnage": 1.42,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 252.1,
      "sensible_heat_ratio_shr": 0.886,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0348",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 39389,
      "heating_infiltration_loss_btu_h": 7847,
      "total_peak_heating_load_btu_h": 47236,
      "summer_conduction_gain_btu_h": 9088,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 1457,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 20211,
      "total_cooling_latent_load_btu_h": 2758,
      "total_cooling_peak_load_btu_h": 22969,
      "calculated_cooling_tonnage": 1.91,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 277,
      "sensible_heat_ratio_shr": 0.88,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0349",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 19036,
      "heating_infiltration_loss_btu_h": 998,
      "total_peak_heating_load_btu_h": 20034,
      "summer_conduction_gain_btu_h": 4523,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 185,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10119,
      "total_cooling_latent_load_btu_h": 824,
      "total_cooling_peak_load_btu_h": 10943,
      "calculated_cooling_tonnage": 0.91,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 229.7,
      "sensible_heat_ratio_shr": 0.925,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0350",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 28888,
      "heating_infiltration_loss_btu_h": 1769,
      "total_peak_heating_load_btu_h": 30657,
      "summer_conduction_gain_btu_h": 6754,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 329,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 14497,
      "total_cooling_latent_load_btu_h": 1196,
      "total_cooling_peak_load_btu_h": 15693,
      "calculated_cooling_tonnage": 1.31,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 281.7,
      "sensible_heat_ratio_shr": 0.924,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0351",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 39389,
      "heating_infiltration_loss_btu_h": 2691,
      "total_peak_heating_load_btu_h": 42080,
      "summer_conduction_gain_btu_h": 9088,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 500,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 19254,
      "total_cooling_latent_load_btu_h": 1603,
      "total_cooling_peak_load_btu_h": 20857,
      "calculated_cooling_tonnage": 1.74,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 313.8,
      "sensible_heat_ratio_shr": 0.923,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0352",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 26773,
      "heating_infiltration_loss_btu_h": 7061,
      "total_peak_heating_load_btu_h": 33834,
      "summer_conduction_gain_btu_h": 5551,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1311,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17514,
      "total_cooling_latent_load_btu_h": 2182,
      "total_cooling_peak_load_btu_h": 19696,
      "calculated_cooling_tonnage": 1.64,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 82.9,
      "sensible_heat_ratio_shr": 0.889,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0353",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 41079,
      "heating_infiltration_loss_btu_h": 12504,
      "total_peak_heating_load_btu_h": 53583,
      "summer_conduction_gain_btu_h": 8441,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 2322,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 26164,
      "total_cooling_latent_load_btu_h": 3602,
      "total_cooling_peak_load_btu_h": 29766,
      "calculated_cooling_tonnage": 2.48,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 101.6,
      "sensible_heat_ratio_shr": 0.879,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0354",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 57173,
      "heating_infiltration_loss_btu_h": 19066,
      "total_peak_heating_load_btu_h": 76239,
      "summer_conduction_gain_btu_h": 11651,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 3541,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 36090,
      "total_cooling_latent_load_btu_h": 5272,
      "total_cooling_peak_load_btu_h": 41362,
      "calculated_cooling_tonnage": 3.45,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 108.7,
      "sensible_heat_ratio_shr": 0.873,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0355",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 26773,
      "heating_infiltration_loss_btu_h": 2911,
      "total_peak_heating_load_btu_h": 29684,
      "summer_conduction_gain_btu_h": 5551,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 541,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16744,
      "total_cooling_latent_load_btu_h": 1252,
      "total_cooling_peak_load_btu_h": 17996,
      "calculated_cooling_tonnage": 1.5,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 100,
      "sensible_heat_ratio_shr": 0.93,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0356",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 41079,
      "heating_infiltration_loss_btu_h": 5148,
      "total_peak_heating_load_btu_h": 46227,
      "summer_conduction_gain_btu_h": 8441,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 956,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 24798,
      "total_cooling_latent_load_btu_h": 1954,
      "total_cooling_peak_load_btu_h": 26752,
      "calculated_cooling_tonnage": 2.23,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 124.2,
      "sensible_heat_ratio_shr": 0.927,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0357",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 57173,
      "heating_infiltration_loss_btu_h": 7847,
      "total_peak_heating_load_btu_h": 65020,
      "summer_conduction_gain_btu_h": 11651,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 1457,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 34006,
      "total_cooling_latent_load_btu_h": 2758,
      "total_cooling_peak_load_btu_h": 36764,
      "calculated_cooling_tonnage": 3.06,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 135.3,
      "sensible_heat_ratio_shr": 0.925,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0358",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 26773,
      "heating_infiltration_loss_btu_h": 998,
      "total_peak_heating_load_btu_h": 27771,
      "summer_conduction_gain_btu_h": 5551,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 185,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16388,
      "total_cooling_latent_load_btu_h": 824,
      "total_cooling_peak_load_btu_h": 17212,
      "calculated_cooling_tonnage": 1.43,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 109.8,
      "sensible_heat_ratio_shr": 0.952,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0359",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 41079,
      "heating_infiltration_loss_btu_h": 1769,
      "total_peak_heating_load_btu_h": 42848,
      "summer_conduction_gain_btu_h": 8441,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 329,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 24171,
      "total_cooling_latent_load_btu_h": 1196,
      "total_cooling_peak_load_btu_h": 25367,
      "calculated_cooling_tonnage": 2.11,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 137,
      "sensible_heat_ratio_shr": 0.953,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0360",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 57173,
      "heating_infiltration_loss_btu_h": 2691,
      "total_peak_heating_load_btu_h": 59864,
      "summer_conduction_gain_btu_h": 11651,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 500,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 33049,
      "total_cooling_latent_load_btu_h": 1603,
      "total_cooling_peak_load_btu_h": 34652,
      "calculated_cooling_tonnage": 2.89,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 149.1,
      "sensible_heat_ratio_shr": 0.954,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0361",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 18394,
      "heating_infiltration_loss_btu_h": 7061,
      "total_peak_heating_load_btu_h": 25455,
      "summer_conduction_gain_btu_h": 3995,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1311,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14430,
      "total_cooling_latent_load_btu_h": 2182,
      "total_cooling_peak_load_btu_h": 16612,
      "calculated_cooling_tonnage": 1.38,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 117.4,
      "sensible_heat_ratio_shr": 0.869,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0362",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 28311,
      "heating_infiltration_loss_btu_h": 12504,
      "total_peak_heating_load_btu_h": 40815,
      "summer_conduction_gain_btu_h": 6069,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 2322,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 21462,
      "total_cooling_latent_load_btu_h": 3602,
      "total_cooling_peak_load_btu_h": 25064,
      "calculated_cooling_tonnage": 2.09,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 139.2,
      "sensible_heat_ratio_shr": 0.856,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0363",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 39218,
      "heating_infiltration_loss_btu_h": 19066,
      "total_peak_heating_load_btu_h": 58284,
      "summer_conduction_gain_btu_h": 8316,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 3541,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 29479,
      "total_cooling_latent_load_btu_h": 5272,
      "total_cooling_peak_load_btu_h": 34751,
      "calculated_cooling_tonnage": 2.9,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 148.3,
      "sensible_heat_ratio_shr": 0.848,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0364",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 18394,
      "heating_infiltration_loss_btu_h": 2911,
      "total_peak_heating_load_btu_h": 21305,
      "summer_conduction_gain_btu_h": 3995,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 541,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13660,
      "total_cooling_latent_load_btu_h": 1252,
      "total_cooling_peak_load_btu_h": 14912,
      "calculated_cooling_tonnage": 1.24,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 141.9,
      "sensible_heat_ratio_shr": 0.916,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0365",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 28311,
      "heating_infiltration_loss_btu_h": 5148,
      "total_peak_heating_load_btu_h": 33459,
      "summer_conduction_gain_btu_h": 6069,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 956,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 20096,
      "total_cooling_latent_load_btu_h": 1954,
      "total_cooling_peak_load_btu_h": 22050,
      "calculated_cooling_tonnage": 1.84,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 171.7,
      "sensible_heat_ratio_shr": 0.911,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0366",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 39218,
      "heating_infiltration_loss_btu_h": 7847,
      "total_peak_heating_load_btu_h": 47065,
      "summer_conduction_gain_btu_h": 8316,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 1457,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 27395,
      "total_cooling_latent_load_btu_h": 2758,
      "total_cooling_peak_load_btu_h": 30153,
      "calculated_cooling_tonnage": 2.51,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 186.9,
      "sensible_heat_ratio_shr": 0.909,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0367",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 18394,
      "heating_infiltration_loss_btu_h": 998,
      "total_peak_heating_load_btu_h": 19392,
      "summer_conduction_gain_btu_h": 3995,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 185,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13304,
      "total_cooling_latent_load_btu_h": 824,
      "total_cooling_peak_load_btu_h": 14128,
      "calculated_cooling_tonnage": 1.18,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 154.2,
      "sensible_heat_ratio_shr": 0.942,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0368",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 28311,
      "heating_infiltration_loss_btu_h": 1769,
      "total_peak_heating_load_btu_h": 30080,
      "summer_conduction_gain_btu_h": 6069,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 329,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 19469,
      "total_cooling_latent_load_btu_h": 1196,
      "total_cooling_peak_load_btu_h": 20665,
      "calculated_cooling_tonnage": 1.72,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 190.7,
      "sensible_heat_ratio_shr": 0.942,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0369",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 39218,
      "heating_infiltration_loss_btu_h": 2691,
      "total_peak_heating_load_btu_h": 41909,
      "summer_conduction_gain_btu_h": 8316,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 500,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 26438,
      "total_cooling_latent_load_btu_h": 1603,
      "total_cooling_peak_load_btu_h": 28041,
      "calculated_cooling_tonnage": 2.34,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 207.7,
      "sensible_heat_ratio_shr": 0.943,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0370",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 15454,
      "heating_infiltration_loss_btu_h": 7061,
      "total_peak_heating_load_btu_h": 22515,
      "summer_conduction_gain_btu_h": 3449,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1311,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10171,
      "total_cooling_latent_load_btu_h": 2182,
      "total_cooling_peak_load_btu_h": 12353,
      "calculated_cooling_tonnage": 1.03,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 191.3,
      "sensible_heat_ratio_shr": 0.823,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0371",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 23831,
      "heating_infiltration_loss_btu_h": 12504,
      "total_peak_heating_load_btu_h": 36335,
      "summer_conduction_gain_btu_h": 5237,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 2322,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 14973,
      "total_cooling_latent_load_btu_h": 3602,
      "total_cooling_peak_load_btu_h": 18575,
      "calculated_cooling_tonnage": 1.55,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 222.6,
      "sensible_heat_ratio_shr": 0.806,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0372",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 32918,
      "heating_infiltration_loss_btu_h": 19066,
      "total_peak_heating_load_btu_h": 51984,
      "summer_conduction_gain_btu_h": 7146,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 3541,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 20353,
      "total_cooling_latent_load_btu_h": 5272,
      "total_cooling_peak_load_btu_h": 25625,
      "calculated_cooling_tonnage": 2.14,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 236.4,
      "sensible_heat_ratio_shr": 0.794,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0373",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 15454,
      "heating_infiltration_loss_btu_h": 2911,
      "total_peak_heating_load_btu_h": 18365,
      "summer_conduction_gain_btu_h": 3449,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 541,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9401,
      "total_cooling_latent_load_btu_h": 1252,
      "total_cooling_peak_load_btu_h": 10653,
      "calculated_cooling_tonnage": 0.89,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 237.1,
      "sensible_heat_ratio_shr": 0.882,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0374",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 23831,
      "heating_infiltration_loss_btu_h": 5148,
      "total_peak_heating_load_btu_h": 28979,
      "summer_conduction_gain_btu_h": 5237,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 956,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 13607,
      "total_cooling_latent_load_btu_h": 1954,
      "total_cooling_peak_load_btu_h": 15561,
      "calculated_cooling_tonnage": 1.3,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 284.6,
      "sensible_heat_ratio_shr": 0.874,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0375",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 32918,
      "heating_infiltration_loss_btu_h": 7847,
      "total_peak_heating_load_btu_h": 40765,
      "summer_conduction_gain_btu_h": 7146,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 1457,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 18269,
      "total_cooling_latent_load_btu_h": 2758,
      "total_cooling_peak_load_btu_h": 21027,
      "calculated_cooling_tonnage": 1.75,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 311.4,
      "sensible_heat_ratio_shr": 0.869,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0376",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 15454,
      "heating_infiltration_loss_btu_h": 998,
      "total_peak_heating_load_btu_h": 16452,
      "summer_conduction_gain_btu_h": 3449,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 185,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9045,
      "total_cooling_latent_load_btu_h": 824,
      "total_cooling_peak_load_btu_h": 9869,
      "calculated_cooling_tonnage": 0.82,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 265.9,
      "sensible_heat_ratio_shr": 0.917,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0377",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 23831,
      "heating_infiltration_loss_btu_h": 1769,
      "total_peak_heating_load_btu_h": 25600,
      "summer_conduction_gain_btu_h": 5237,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 329,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 12980,
      "total_cooling_latent_load_btu_h": 1196,
      "total_cooling_peak_load_btu_h": 14176,
      "calculated_cooling_tonnage": 1.18,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 323.7,
      "sensible_heat_ratio_shr": 0.916,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0378",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 32918,
      "heating_infiltration_loss_btu_h": 2691,
      "total_peak_heating_load_btu_h": 35609,
      "summer_conduction_gain_btu_h": 7146,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 500,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 17312,
      "total_cooling_latent_load_btu_h": 1603,
      "total_cooling_peak_load_btu_h": 18915,
      "calculated_cooling_tonnage": 1.58,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 355.7,
      "sensible_heat_ratio_shr": 0.915,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0379",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 25857,
      "heating_infiltration_loss_btu_h": 7061,
      "total_peak_heating_load_btu_h": 32918,
      "summer_conduction_gain_btu_h": 5276,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1311,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17239,
      "total_cooling_latent_load_btu_h": 2182,
      "total_cooling_peak_load_btu_h": 19421,
      "calculated_cooling_tonnage": 1.62,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 85.2,
      "sensible_heat_ratio_shr": 0.888,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0380",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 39785,
      "heating_infiltration_loss_btu_h": 12504,
      "total_peak_heating_load_btu_h": 52289,
      "summer_conduction_gain_btu_h": 8053,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 2322,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 25776,
      "total_cooling_latent_load_btu_h": 3602,
      "total_cooling_peak_load_btu_h": 29378,
      "calculated_cooling_tonnage": 2.45,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 104.1,
      "sensible_heat_ratio_shr": 0.877,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0381",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 55517,
      "heating_infiltration_loss_btu_h": 19066,
      "total_peak_heating_load_btu_h": 74583,
      "summer_conduction_gain_btu_h": 11154,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 3541,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 35593,
      "total_cooling_latent_load_btu_h": 5272,
      "total_cooling_peak_load_btu_h": 40865,
      "calculated_cooling_tonnage": 3.41,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 111.1,
      "sensible_heat_ratio_shr": 0.871,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0382",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 25857,
      "heating_infiltration_loss_btu_h": 2911,
      "total_peak_heating_load_btu_h": 28768,
      "summer_conduction_gain_btu_h": 5276,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 541,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16469,
      "total_cooling_latent_load_btu_h": 1252,
      "total_cooling_peak_load_btu_h": 17721,
      "calculated_cooling_tonnage": 1.48,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 102.7,
      "sensible_heat_ratio_shr": 0.929,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0383",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 39785,
      "heating_infiltration_loss_btu_h": 5148,
      "total_peak_heating_load_btu_h": 44933,
      "summer_conduction_gain_btu_h": 8053,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 956,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 24410,
      "total_cooling_latent_load_btu_h": 1954,
      "total_cooling_peak_load_btu_h": 26364,
      "calculated_cooling_tonnage": 2.2,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 127.3,
      "sensible_heat_ratio_shr": 0.926,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0384",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 55517,
      "heating_infiltration_loss_btu_h": 7847,
      "total_peak_heating_load_btu_h": 63364,
      "summer_conduction_gain_btu_h": 11154,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 1457,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 33509,
      "total_cooling_latent_load_btu_h": 2758,
      "total_cooling_peak_load_btu_h": 36267,
      "calculated_cooling_tonnage": 3.02,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 138.4,
      "sensible_heat_ratio_shr": 0.924,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0385",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 25857,
      "heating_infiltration_loss_btu_h": 998,
      "total_peak_heating_load_btu_h": 26855,
      "summer_conduction_gain_btu_h": 5276,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 185,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16113,
      "total_cooling_latent_load_btu_h": 824,
      "total_cooling_peak_load_btu_h": 16937,
      "calculated_cooling_tonnage": 1.41,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 112.8,
      "sensible_heat_ratio_shr": 0.951,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0386",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 39785,
      "heating_infiltration_loss_btu_h": 1769,
      "total_peak_heating_load_btu_h": 41554,
      "summer_conduction_gain_btu_h": 8053,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 329,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 23783,
      "total_cooling_latent_load_btu_h": 1196,
      "total_cooling_peak_load_btu_h": 24979,
      "calculated_cooling_tonnage": 2.08,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 140.4,
      "sensible_heat_ratio_shr": 0.952,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0387",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 55517,
      "heating_infiltration_loss_btu_h": 2691,
      "total_peak_heating_load_btu_h": 58208,
      "summer_conduction_gain_btu_h": 11154,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 500,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 32552,
      "total_cooling_latent_load_btu_h": 1603,
      "total_cooling_peak_load_btu_h": 34155,
      "calculated_cooling_tonnage": 2.85,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 152.6,
      "sensible_heat_ratio_shr": 0.953,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0388",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 17478,
      "heating_infiltration_loss_btu_h": 7061,
      "total_peak_heating_load_btu_h": 24539,
      "summer_conduction_gain_btu_h": 3720,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1311,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14155,
      "total_cooling_latent_load_btu_h": 2182,
      "total_cooling_peak_load_btu_h": 16337,
      "calculated_cooling_tonnage": 1.36,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 120.6,
      "sensible_heat_ratio_shr": 0.866,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0389",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 27017,
      "heating_infiltration_loss_btu_h": 12504,
      "total_peak_heating_load_btu_h": 39521,
      "summer_conduction_gain_btu_h": 5681,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 2322,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 21074,
      "total_cooling_latent_load_btu_h": 3602,
      "total_cooling_peak_load_btu_h": 24676,
      "calculated_cooling_tonnage": 2.06,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 142.7,
      "sensible_heat_ratio_shr": 0.854,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0390",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 37562,
      "heating_infiltration_loss_btu_h": 19066,
      "total_peak_heating_load_btu_h": 56628,
      "summer_conduction_gain_btu_h": 7820,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 3541,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 28983,
      "total_cooling_latent_load_btu_h": 5272,
      "total_cooling_peak_load_btu_h": 34255,
      "calculated_cooling_tonnage": 2.85,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 152.6,
      "sensible_heat_ratio_shr": 0.846,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0391",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 17478,
      "heating_infiltration_loss_btu_h": 2911,
      "total_peak_heating_load_btu_h": 20389,
      "summer_conduction_gain_btu_h": 3720,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 541,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13385,
      "total_cooling_latent_load_btu_h": 1252,
      "total_cooling_peak_load_btu_h": 14637,
      "calculated_cooling_tonnage": 1.22,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 145.9,
      "sensible_heat_ratio_shr": 0.914,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0392",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 27017,
      "heating_infiltration_loss_btu_h": 5148,
      "total_peak_heating_load_btu_h": 32165,
      "summer_conduction_gain_btu_h": 5681,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 956,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 19708,
      "total_cooling_latent_load_btu_h": 1954,
      "total_cooling_peak_load_btu_h": 21662,
      "calculated_cooling_tonnage": 1.81,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 176.2,
      "sensible_heat_ratio_shr": 0.91,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0393",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 37562,
      "heating_infiltration_loss_btu_h": 7847,
      "total_peak_heating_load_btu_h": 45409,
      "summer_conduction_gain_btu_h": 7820,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 1457,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 26899,
      "total_cooling_latent_load_btu_h": 2758,
      "total_cooling_peak_load_btu_h": 29657,
      "calculated_cooling_tonnage": 2.47,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 191.5,
      "sensible_heat_ratio_shr": 0.907,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0394",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 17478,
      "heating_infiltration_loss_btu_h": 998,
      "total_peak_heating_load_btu_h": 18476,
      "summer_conduction_gain_btu_h": 3720,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 185,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13029,
      "total_cooling_latent_load_btu_h": 824,
      "total_cooling_peak_load_btu_h": 13853,
      "calculated_cooling_tonnage": 1.15,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 160.9,
      "sensible_heat_ratio_shr": 0.941,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0395",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 27017,
      "heating_infiltration_loss_btu_h": 1769,
      "total_peak_heating_load_btu_h": 28786,
      "summer_conduction_gain_btu_h": 5681,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 329,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 19081,
      "total_cooling_latent_load_btu_h": 1196,
      "total_cooling_peak_load_btu_h": 20277,
      "calculated_cooling_tonnage": 1.69,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 195.9,
      "sensible_heat_ratio_shr": 0.941,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0396",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 37562,
      "heating_infiltration_loss_btu_h": 2691,
      "total_peak_heating_load_btu_h": 40253,
      "summer_conduction_gain_btu_h": 7820,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 500,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 25942,
      "total_cooling_latent_load_btu_h": 1603,
      "total_cooling_peak_load_btu_h": 27545,
      "calculated_cooling_tonnage": 2.3,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 213,
      "sensible_heat_ratio_shr": 0.942,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0397",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 14538,
      "heating_infiltration_loss_btu_h": 7061,
      "total_peak_heating_load_btu_h": 21599,
      "summer_conduction_gain_btu_h": 3174,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1311,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9896,
      "total_cooling_latent_load_btu_h": 2182,
      "total_cooling_peak_load_btu_h": 12078,
      "calculated_cooling_tonnage": 1.01,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 197,
      "sensible_heat_ratio_shr": 0.819,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0398",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 22537,
      "heating_infiltration_loss_btu_h": 12504,
      "total_peak_heating_load_btu_h": 35041,
      "summer_conduction_gain_btu_h": 4849,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 2322,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 14585,
      "total_cooling_latent_load_btu_h": 3602,
      "total_cooling_peak_load_btu_h": 18187,
      "calculated_cooling_tonnage": 1.52,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 228.9,
      "sensible_heat_ratio_shr": 0.802,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0399",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 31262,
      "heating_infiltration_loss_btu_h": 19066,
      "total_peak_heating_load_btu_h": 50328,
      "summer_conduction_gain_btu_h": 6650,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 3541,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 19857,
      "total_cooling_latent_load_btu_h": 5272,
      "total_cooling_peak_load_btu_h": 25129,
      "calculated_cooling_tonnage": 2.09,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 244.5,
      "sensible_heat_ratio_shr": 0.79,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0400",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 14538,
      "heating_infiltration_loss_btu_h": 2911,
      "total_peak_heating_load_btu_h": 17449,
      "summer_conduction_gain_btu_h": 3174,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 541,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9126,
      "total_cooling_latent_load_btu_h": 1252,
      "total_cooling_peak_load_btu_h": 10378,
      "calculated_cooling_tonnage": 0.86,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 248.8,
      "sensible_heat_ratio_shr": 0.879,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0401",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 22537,
      "heating_infiltration_loss_btu_h": 5148,
      "total_peak_heating_load_btu_h": 27685,
      "summer_conduction_gain_btu_h": 4849,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 956,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 13219,
      "total_cooling_latent_load_btu_h": 1954,
      "total_cooling_peak_load_btu_h": 15173,
      "calculated_cooling_tonnage": 1.26,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 296.8,
      "sensible_heat_ratio_shr": 0.871,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0402",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 31262,
      "heating_infiltration_loss_btu_h": 7847,
      "total_peak_heating_load_btu_h": 39109,
      "summer_conduction_gain_btu_h": 6650,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 1457,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 17773,
      "total_cooling_latent_load_btu_h": 2758,
      "total_cooling_peak_load_btu_h": 20531,
      "calculated_cooling_tonnage": 1.71,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 321.1,
      "sensible_heat_ratio_shr": 0.866,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0403",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 14538,
      "heating_infiltration_loss_btu_h": 998,
      "total_peak_heating_load_btu_h": 15536,
      "summer_conduction_gain_btu_h": 3174,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 185,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 8770,
      "total_cooling_latent_load_btu_h": 824,
      "total_cooling_peak_load_btu_h": 9594,
      "calculated_cooling_tonnage": 0.8,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 275,
      "sensible_heat_ratio_shr": 0.914,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0404",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 22537,
      "heating_infiltration_loss_btu_h": 1769,
      "total_peak_heating_load_btu_h": 24306,
      "summer_conduction_gain_btu_h": 4849,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 329,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 12592,
      "total_cooling_latent_load_btu_h": 1196,
      "total_cooling_peak_load_btu_h": 13788,
      "calculated_cooling_tonnage": 1.15,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 334.8,
      "sensible_heat_ratio_shr": 0.913,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0405",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 31262,
      "heating_infiltration_loss_btu_h": 2691,
      "total_peak_heating_load_btu_h": 33953,
      "summer_conduction_gain_btu_h": 6650,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 500,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 16816,
      "total_cooling_latent_load_btu_h": 1603,
      "total_cooling_peak_load_btu_h": 18419,
      "calculated_cooling_tonnage": 1.53,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 370.6,
      "sensible_heat_ratio_shr": 0.913,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0406",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 24857,
      "heating_infiltration_loss_btu_h": 7061,
      "total_peak_heating_load_btu_h": 31918,
      "summer_conduction_gain_btu_h": 4976,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1311,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16939,
      "total_cooling_latent_load_btu_h": 2182,
      "total_cooling_peak_load_btu_h": 19121,
      "calculated_cooling_tonnage": 1.59,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 88.7,
      "sensible_heat_ratio_shr": 0.886,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0407",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 38374,
      "heating_infiltration_loss_btu_h": 12504,
      "total_peak_heating_load_btu_h": 50878,
      "summer_conduction_gain_btu_h": 7629,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 2322,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 25352,
      "total_cooling_latent_load_btu_h": 3602,
      "total_cooling_peak_load_btu_h": 28954,
      "calculated_cooling_tonnage": 2.41,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 107.5,
      "sensible_heat_ratio_shr": 0.876,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0408",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 53711,
      "heating_infiltration_loss_btu_h": 19066,
      "total_peak_heating_load_btu_h": 72777,
      "summer_conduction_gain_btu_h": 10613,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 3541,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 35052,
      "total_cooling_latent_load_btu_h": 5272,
      "total_cooling_peak_load_btu_h": 40324,
      "calculated_cooling_tonnage": 3.36,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 114.3,
      "sensible_heat_ratio_shr": 0.869,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0409",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 24857,
      "heating_infiltration_loss_btu_h": 2911,
      "total_peak_heating_load_btu_h": 27768,
      "summer_conduction_gain_btu_h": 4976,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 541,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16169,
      "total_cooling_latent_load_btu_h": 1252,
      "total_cooling_peak_load_btu_h": 17421,
      "calculated_cooling_tonnage": 1.45,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 106.9,
      "sensible_heat_ratio_shr": 0.928,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0410",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 38374,
      "heating_infiltration_loss_btu_h": 5148,
      "total_peak_heating_load_btu_h": 43522,
      "summer_conduction_gain_btu_h": 7629,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 956,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 23986,
      "total_cooling_latent_load_btu_h": 1954,
      "total_cooling_peak_load_btu_h": 25940,
      "calculated_cooling_tonnage": 2.16,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 131.5,
      "sensible_heat_ratio_shr": 0.925,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0411",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 53711,
      "heating_infiltration_loss_btu_h": 7847,
      "total_peak_heating_load_btu_h": 61558,
      "summer_conduction_gain_btu_h": 10613,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 1457,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 32968,
      "total_cooling_latent_load_btu_h": 2758,
      "total_cooling_peak_load_btu_h": 35726,
      "calculated_cooling_tonnage": 2.98,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 141.6,
      "sensible_heat_ratio_shr": 0.923,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0412",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 24857,
      "heating_infiltration_loss_btu_h": 998,
      "total_peak_heating_load_btu_h": 25855,
      "summer_conduction_gain_btu_h": 4976,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 185,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15813,
      "total_cooling_latent_load_btu_h": 824,
      "total_cooling_peak_load_btu_h": 16637,
      "calculated_cooling_tonnage": 1.39,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 115.8,
      "sensible_heat_ratio_shr": 0.95,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0413",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 38374,
      "heating_infiltration_loss_btu_h": 1769,
      "total_peak_heating_load_btu_h": 40143,
      "summer_conduction_gain_btu_h": 7629,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 329,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 23359,
      "total_cooling_latent_load_btu_h": 1196,
      "total_cooling_peak_load_btu_h": 24555,
      "calculated_cooling_tonnage": 2.05,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 143.9,
      "sensible_heat_ratio_shr": 0.951,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0414",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 53711,
      "heating_infiltration_loss_btu_h": 2691,
      "total_peak_heating_load_btu_h": 56402,
      "summer_conduction_gain_btu_h": 10613,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 500,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 32011,
      "total_cooling_latent_load_btu_h": 1603,
      "total_cooling_peak_load_btu_h": 33614,
      "calculated_cooling_tonnage": 2.8,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 157.1,
      "sensible_heat_ratio_shr": 0.952,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0415",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 16478,
      "heating_infiltration_loss_btu_h": 7061,
      "total_peak_heating_load_btu_h": 23539,
      "summer_conduction_gain_btu_h": 3420,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1311,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13855,
      "total_cooling_latent_load_btu_h": 2182,
      "total_cooling_peak_load_btu_h": 16037,
      "calculated_cooling_tonnage": 1.34,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 123.9,
      "sensible_heat_ratio_shr": 0.864,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0416",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 25606,
      "heating_infiltration_loss_btu_h": 12504,
      "total_peak_heating_load_btu_h": 38110,
      "summer_conduction_gain_btu_h": 5258,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 2322,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 20651,
      "total_cooling_latent_load_btu_h": 3602,
      "total_cooling_peak_load_btu_h": 24253,
      "calculated_cooling_tonnage": 2.02,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 147.5,
      "sensible_heat_ratio_shr": 0.851,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0417",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 35756,
      "heating_infiltration_loss_btu_h": 19066,
      "total_peak_heating_load_btu_h": 54822,
      "summer_conduction_gain_btu_h": 7278,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 3541,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 28441,
      "total_cooling_latent_load_btu_h": 5272,
      "total_cooling_peak_load_btu_h": 33713,
      "calculated_cooling_tonnage": 2.81,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 156.2,
      "sensible_heat_ratio_shr": 0.844,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0418",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 16478,
      "heating_infiltration_loss_btu_h": 2911,
      "total_peak_heating_load_btu_h": 19389,
      "summer_conduction_gain_btu_h": 3420,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 541,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13085,
      "total_cooling_latent_load_btu_h": 1252,
      "total_cooling_peak_load_btu_h": 14337,
      "calculated_cooling_tonnage": 1.19,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 152.1,
      "sensible_heat_ratio_shr": 0.913,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0419",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 25606,
      "heating_infiltration_loss_btu_h": 5148,
      "total_peak_heating_load_btu_h": 30754,
      "summer_conduction_gain_btu_h": 5258,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 956,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 19285,
      "total_cooling_latent_load_btu_h": 1954,
      "total_cooling_peak_load_btu_h": 21239,
      "calculated_cooling_tonnage": 1.77,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 182.5,
      "sensible_heat_ratio_shr": 0.908,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0420",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 35756,
      "heating_infiltration_loss_btu_h": 7847,
      "total_peak_heating_load_btu_h": 43603,
      "summer_conduction_gain_btu_h": 7278,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 1457,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 26357,
      "total_cooling_latent_load_btu_h": 2758,
      "total_cooling_peak_load_btu_h": 29115,
      "calculated_cooling_tonnage": 2.43,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 196.3,
      "sensible_heat_ratio_shr": 0.905,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0421",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 16478,
      "heating_infiltration_loss_btu_h": 998,
      "total_peak_heating_load_btu_h": 17476,
      "summer_conduction_gain_btu_h": 3420,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 185,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 12729,
      "total_cooling_latent_load_btu_h": 824,
      "total_cooling_peak_load_btu_h": 13553,
      "calculated_cooling_tonnage": 1.13,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 165.5,
      "sensible_heat_ratio_shr": 0.939,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0422",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 25606,
      "heating_infiltration_loss_btu_h": 1769,
      "total_peak_heating_load_btu_h": 27375,
      "summer_conduction_gain_btu_h": 5258,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 329,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 18658,
      "total_cooling_latent_load_btu_h": 1196,
      "total_cooling_peak_load_btu_h": 19854,
      "calculated_cooling_tonnage": 1.65,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 203,
      "sensible_heat_ratio_shr": 0.94,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0423",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 35756,
      "heating_infiltration_loss_btu_h": 2691,
      "total_peak_heating_load_btu_h": 38447,
      "summer_conduction_gain_btu_h": 7278,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 500,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 25400,
      "total_cooling_latent_load_btu_h": 1603,
      "total_cooling_peak_load_btu_h": 27003,
      "calculated_cooling_tonnage": 2.25,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 220,
      "sensible_heat_ratio_shr": 0.941,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0424",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 13538,
      "heating_infiltration_loss_btu_h": 7061,
      "total_peak_heating_load_btu_h": 20599,
      "summer_conduction_gain_btu_h": 2874,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1311,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9596,
      "total_cooling_latent_load_btu_h": 2182,
      "total_cooling_peak_load_btu_h": 11778,
      "calculated_cooling_tonnage": 0.98,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 206.1,
      "sensible_heat_ratio_shr": 0.815,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0425",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 21126,
      "heating_infiltration_loss_btu_h": 12504,
      "total_peak_heating_load_btu_h": 33630,
      "summer_conduction_gain_btu_h": 4426,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 2322,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 14162,
      "total_cooling_latent_load_btu_h": 3602,
      "total_cooling_peak_load_btu_h": 17764,
      "calculated_cooling_tonnage": 1.48,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 237.8,
      "sensible_heat_ratio_shr": 0.797,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0426",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 29456,
      "heating_infiltration_loss_btu_h": 19066,
      "total_peak_heating_load_btu_h": 48522,
      "summer_conduction_gain_btu_h": 6108,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 3541,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 19315,
      "total_cooling_latent_load_btu_h": 5272,
      "total_cooling_peak_load_btu_h": 24587,
      "calculated_cooling_tonnage": 2.05,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 251.2,
      "sensible_heat_ratio_shr": 0.786,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0427",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 13538,
      "heating_infiltration_loss_btu_h": 2911,
      "total_peak_heating_load_btu_h": 16449,
      "summer_conduction_gain_btu_h": 2874,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 541,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 8826,
      "total_cooling_latent_load_btu_h": 1252,
      "total_cooling_peak_load_btu_h": 10078,
      "calculated_cooling_tonnage": 0.84,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 257.1,
      "sensible_heat_ratio_shr": 0.876,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0428",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 21126,
      "heating_infiltration_loss_btu_h": 5148,
      "total_peak_heating_load_btu_h": 26274,
      "summer_conduction_gain_btu_h": 4426,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 956,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 12796,
      "total_cooling_latent_load_btu_h": 1954,
      "total_cooling_peak_load_btu_h": 14750,
      "calculated_cooling_tonnage": 1.23,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 306.5,
      "sensible_heat_ratio_shr": 0.868,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0429",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 29456,
      "heating_infiltration_loss_btu_h": 7847,
      "total_peak_heating_load_btu_h": 37303,
      "summer_conduction_gain_btu_h": 6108,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 1457,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 17231,
      "total_cooling_latent_load_btu_h": 2758,
      "total_cooling_peak_load_btu_h": 19989,
      "calculated_cooling_tonnage": 1.67,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 331.1,
      "sensible_heat_ratio_shr": 0.862,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0430",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 13538,
      "heating_infiltration_loss_btu_h": 998,
      "total_peak_heating_load_btu_h": 14536,
      "summer_conduction_gain_btu_h": 2874,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 185,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 8470,
      "total_cooling_latent_load_btu_h": 824,
      "total_cooling_peak_load_btu_h": 9294,
      "calculated_cooling_tonnage": 0.77,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 289.6,
      "sensible_heat_ratio_shr": 0.911,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0431",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 21126,
      "heating_infiltration_loss_btu_h": 1769,
      "total_peak_heating_load_btu_h": 22895,
      "summer_conduction_gain_btu_h": 4426,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 329,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 12169,
      "total_cooling_latent_load_btu_h": 1196,
      "total_cooling_peak_load_btu_h": 13365,
      "calculated_cooling_tonnage": 1.11,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 350.5,
      "sensible_heat_ratio_shr": 0.911,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0432",
      "climate_zone": "CZ-5",
      "climate_zone_name": "Cold (Chicago/Denver)",
      "outdoor_winter_db_f": 0,
      "outdoor_summer_db_f": 88,
      "outdoor_summer_wb_f": 72,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 29456,
      "heating_infiltration_loss_btu_h": 2691,
      "total_peak_heating_load_btu_h": 32147,
      "summer_conduction_gain_btu_h": 6108,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 500,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 16274,
      "total_cooling_latent_load_btu_h": 1603,
      "total_cooling_peak_load_btu_h": 17877,
      "calculated_cooling_tonnage": 1.49,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 383.2,
      "sensible_heat_ratio_shr": 0.91,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0433",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 36859,
      "heating_infiltration_loss_btu_h": 8574,
      "total_peak_heating_load_btu_h": 45433,
      "summer_conduction_gain_btu_h": 5872,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1110,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 17634,
      "total_cooling_latent_load_btu_h": 1730,
      "total_cooling_peak_load_btu_h": 19364,
      "calculated_cooling_tonnage": 1.61,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 86.3,
      "sensible_heat_ratio_shr": 0.911,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0434",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 56022,
      "heating_infiltration_loss_btu_h": 15184,
      "total_peak_heating_load_btu_h": 71206,
      "summer_conduction_gain_btu_h": 8830,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1965,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 26196,
      "total_cooling_latent_load_btu_h": 2801,
      "total_cooling_peak_load_btu_h": 28997,
      "calculated_cooling_tonnage": 2.42,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 106.6,
      "sensible_heat_ratio_shr": 0.903,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0435",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 77282,
      "heating_infiltration_loss_btu_h": 23152,
      "total_peak_heating_load_btu_h": 100434,
      "summer_conduction_gain_btu_h": 12048,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 2996,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 35942,
      "total_cooling_latent_load_btu_h": 4052,
      "total_cooling_peak_load_btu_h": 39994,
      "calculated_cooling_tonnage": 3.33,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 116.2,
      "sensible_heat_ratio_shr": 0.899,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0436",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 36859,
      "heating_infiltration_loss_btu_h": 3534,
      "total_peak_heating_load_btu_h": 40393,
      "summer_conduction_gain_btu_h": 5872,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 457,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16981,
      "total_cooling_latent_load_btu_h": 1066,
      "total_cooling_peak_load_btu_h": 18047,
      "calculated_cooling_tonnage": 1.5,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 100,
      "sensible_heat_ratio_shr": 0.941,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0437",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 56022,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 62274,
      "summer_conduction_gain_btu_h": 8830,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 809,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 25040,
      "total_cooling_latent_load_btu_h": 1624,
      "total_cooling_peak_load_btu_h": 26664,
      "calculated_cooling_tonnage": 2.22,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 125.2,
      "sensible_heat_ratio_shr": 0.939,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0438",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 77282,
      "heating_infiltration_loss_btu_h": 9529,
      "total_peak_heating_load_btu_h": 86811,
      "summer_conduction_gain_btu_h": 12048,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 1233,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 34179,
      "total_cooling_latent_load_btu_h": 2256,
      "total_cooling_peak_load_btu_h": 36435,
      "calculated_cooling_tonnage": 3.04,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 136.8,
      "sensible_heat_ratio_shr": 0.938,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0439",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 36859,
      "heating_infiltration_loss_btu_h": 1212,
      "total_peak_heating_load_btu_h": 38071,
      "summer_conduction_gain_btu_h": 5872,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 157,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16681,
      "total_cooling_latent_load_btu_h": 760,
      "total_cooling_peak_load_btu_h": 17441,
      "calculated_cooling_tonnage": 1.45,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 106.9,
      "sensible_heat_ratio_shr": 0.956,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0440",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 56022,
      "heating_infiltration_loss_btu_h": 2148,
      "total_peak_heating_load_btu_h": 58170,
      "summer_conduction_gain_btu_h": 8830,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 278,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 24509,
      "total_cooling_latent_load_btu_h": 1083,
      "total_cooling_peak_load_btu_h": 25592,
      "calculated_cooling_tonnage": 2.13,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 134.7,
      "sensible_heat_ratio_shr": 0.958,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0441",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 77282,
      "heating_infiltration_loss_btu_h": 3268,
      "total_peak_heating_load_btu_h": 80550,
      "summer_conduction_gain_btu_h": 12048,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 423,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 33369,
      "total_cooling_latent_load_btu_h": 1431,
      "total_cooling_peak_load_btu_h": 34800,
      "calculated_cooling_tonnage": 2.9,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 148.3,
      "sensible_heat_ratio_shr": 0.959,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0442",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 26685,
      "heating_infiltration_loss_btu_h": 8574,
      "total_peak_heating_load_btu_h": 35259,
      "summer_conduction_gain_btu_h": 4555,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1110,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14789,
      "total_cooling_latent_load_btu_h": 1730,
      "total_cooling_peak_load_btu_h": 16519,
      "calculated_cooling_tonnage": 1.38,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 117.4,
      "sensible_heat_ratio_shr": 0.895,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0443",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 40518,
      "heating_infiltration_loss_btu_h": 15184,
      "total_peak_heating_load_btu_h": 55702,
      "summer_conduction_gain_btu_h": 6823,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1965,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 21859,
      "total_cooling_latent_load_btu_h": 2801,
      "total_cooling_peak_load_btu_h": 24660,
      "calculated_cooling_tonnage": 2.06,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 142.7,
      "sensible_heat_ratio_shr": 0.886,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0444",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 55480,
      "heating_infiltration_loss_btu_h": 23152,
      "total_peak_heating_load_btu_h": 78632,
      "summer_conduction_gain_btu_h": 9226,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 2996,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 29844,
      "total_cooling_latent_load_btu_h": 4052,
      "total_cooling_peak_load_btu_h": 33896,
      "calculated_cooling_tonnage": 2.82,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 155.3,
      "sensible_heat_ratio_shr": 0.88,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0445",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 26685,
      "heating_infiltration_loss_btu_h": 3534,
      "total_peak_heating_load_btu_h": 30219,
      "summer_conduction_gain_btu_h": 4555,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 457,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 14136,
      "total_cooling_latent_load_btu_h": 1066,
      "total_cooling_peak_load_btu_h": 15202,
      "calculated_cooling_tonnage": 1.27,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 136.2,
      "sensible_heat_ratio_shr": 0.93,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0446",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 40518,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 46770,
      "summer_conduction_gain_btu_h": 6823,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 809,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 20703,
      "total_cooling_latent_load_btu_h": 1624,
      "total_cooling_peak_load_btu_h": 22327,
      "calculated_cooling_tonnage": 1.86,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 168.8,
      "sensible_heat_ratio_shr": 0.927,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0447",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 55480,
      "heating_infiltration_loss_btu_h": 9529,
      "total_peak_heating_load_btu_h": 65009,
      "summer_conduction_gain_btu_h": 9226,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 1233,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 28081,
      "total_cooling_latent_load_btu_h": 2256,
      "total_cooling_peak_load_btu_h": 30337,
      "calculated_cooling_tonnage": 2.53,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 184.6,
      "sensible_heat_ratio_shr": 0.926,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0448",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 26685,
      "heating_infiltration_loss_btu_h": 1212,
      "total_peak_heating_load_btu_h": 27897,
      "summer_conduction_gain_btu_h": 4555,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 157,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13836,
      "total_cooling_latent_load_btu_h": 760,
      "total_cooling_peak_load_btu_h": 14596,
      "calculated_cooling_tonnage": 1.22,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 145.9,
      "sensible_heat_ratio_shr": 0.948,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0449",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 40518,
      "heating_infiltration_loss_btu_h": 2148,
      "total_peak_heating_load_btu_h": 42666,
      "summer_conduction_gain_btu_h": 6823,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 278,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 20172,
      "total_cooling_latent_load_btu_h": 1083,
      "total_cooling_peak_load_btu_h": 21255,
      "calculated_cooling_tonnage": 1.77,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 182.5,
      "sensible_heat_ratio_shr": 0.949,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0450",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 55480,
      "heating_infiltration_loss_btu_h": 3268,
      "total_peak_heating_load_btu_h": 58748,
      "summer_conduction_gain_btu_h": 9226,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 423,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 27271,
      "total_cooling_latent_load_btu_h": 1431,
      "total_cooling_peak_load_btu_h": 28702,
      "calculated_cooling_tonnage": 2.39,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 201.3,
      "sensible_heat_ratio_shr": 0.95,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0451",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 23115,
      "heating_infiltration_loss_btu_h": 8574,
      "total_peak_heating_load_btu_h": 31689,
      "summer_conduction_gain_btu_h": 4093,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1110,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 10614,
      "total_cooling_latent_load_btu_h": 1730,
      "total_cooling_peak_load_btu_h": 12344,
      "calculated_cooling_tonnage": 1.03,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 191.3,
      "sensible_heat_ratio_shr": 0.86,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0452",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 35078,
      "heating_infiltration_loss_btu_h": 15184,
      "total_peak_heating_load_btu_h": 50262,
      "summer_conduction_gain_btu_h": 6119,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1965,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 15498,
      "total_cooling_latent_load_btu_h": 2801,
      "total_cooling_peak_load_btu_h": 18299,
      "calculated_cooling_tonnage": 1.52,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 228.9,
      "sensible_heat_ratio_shr": 0.847,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0453",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 47830,
      "heating_infiltration_loss_btu_h": 23152,
      "total_peak_heating_load_btu_h": 70982,
      "summer_conduction_gain_btu_h": 8236,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 2996,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 20898,
      "total_cooling_latent_load_btu_h": 4052,
      "total_cooling_peak_load_btu_h": 24950,
      "calculated_cooling_tonnage": 2.08,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 246.2,
      "sensible_heat_ratio_shr": 0.838,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0454",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 23115,
      "heating_infiltration_loss_btu_h": 3534,
      "total_peak_heating_load_btu_h": 26649,
      "summer_conduction_gain_btu_h": 4093,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 457,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9961,
      "total_cooling_latent_load_btu_h": 1066,
      "total_cooling_peak_load_btu_h": 11027,
      "calculated_cooling_tonnage": 0.92,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 226.1,
      "sensible_heat_ratio_shr": 0.903,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0455",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 35078,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 41330,
      "summer_conduction_gain_btu_h": 6119,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 809,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 14342,
      "total_cooling_latent_load_btu_h": 1624,
      "total_cooling_peak_load_btu_h": 15966,
      "calculated_cooling_tonnage": 1.33,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 275.9,
      "sensible_heat_ratio_shr": 0.898,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0456",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 47830,
      "heating_infiltration_loss_btu_h": 9529,
      "total_peak_heating_load_btu_h": 57359,
      "summer_conduction_gain_btu_h": 8236,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 1233,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 19135,
      "total_cooling_latent_load_btu_h": 2256,
      "total_cooling_peak_load_btu_h": 21391,
      "calculated_cooling_tonnage": 1.78,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 304.5,
      "sensible_heat_ratio_shr": 0.895,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0457",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 23115,
      "heating_infiltration_loss_btu_h": 1212,
      "total_peak_heating_load_btu_h": 24327,
      "summer_conduction_gain_btu_h": 4093,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 157,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9661,
      "total_cooling_latent_load_btu_h": 760,
      "total_cooling_peak_load_btu_h": 10421,
      "calculated_cooling_tonnage": 0.87,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 244.8,
      "sensible_heat_ratio_shr": 0.927,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0458",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 35078,
      "heating_infiltration_loss_btu_h": 2148,
      "total_peak_heating_load_btu_h": 37226,
      "summer_conduction_gain_btu_h": 6119,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 278,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 13811,
      "total_cooling_latent_load_btu_h": 1083,
      "total_cooling_peak_load_btu_h": 14894,
      "calculated_cooling_tonnage": 1.24,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 303.2,
      "sensible_heat_ratio_shr": 0.927,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0459",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-11_2x4_16OC_Legacy",
      "wall_effective_u_factor": 0.106,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 47830,
      "heating_infiltration_loss_btu_h": 3268,
      "total_peak_heating_load_btu_h": 51098,
      "summer_conduction_gain_btu_h": 8236,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 423,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 18325,
      "total_cooling_latent_load_btu_h": 1431,
      "total_cooling_peak_load_btu_h": 19756,
      "calculated_cooling_tonnage": 1.65,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 336.4,
      "sensible_heat_ratio_shr": 0.928,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0460",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 32510,
      "heating_infiltration_loss_btu_h": 8574,
      "total_peak_heating_load_btu_h": 41084,
      "summer_conduction_gain_btu_h": 4900,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1110,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16662,
      "total_cooling_latent_load_btu_h": 1730,
      "total_cooling_peak_load_btu_h": 18392,
      "calculated_cooling_tonnage": 1.53,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 96.1,
      "sensible_heat_ratio_shr": 0.906,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0461",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 49881,
      "heating_infiltration_loss_btu_h": 15184,
      "total_peak_heating_load_btu_h": 65065,
      "summer_conduction_gain_btu_h": 7457,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1965,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 24823,
      "total_cooling_latent_load_btu_h": 2801,
      "total_cooling_peak_load_btu_h": 27624,
      "calculated_cooling_tonnage": 2.3,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 117.4,
      "sensible_heat_ratio_shr": 0.899,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0462",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 69424,
      "heating_infiltration_loss_btu_h": 23152,
      "total_peak_heating_load_btu_h": 92576,
      "summer_conduction_gain_btu_h": 10291,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 2996,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 34185,
      "total_cooling_latent_load_btu_h": 4052,
      "total_cooling_peak_load_btu_h": 38237,
      "calculated_cooling_tonnage": 3.19,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 125.7,
      "sensible_heat_ratio_shr": 0.894,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0463",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 32510,
      "heating_infiltration_loss_btu_h": 3534,
      "total_peak_heating_load_btu_h": 36044,
      "summer_conduction_gain_btu_h": 4900,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 457,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16009,
      "total_cooling_latent_load_btu_h": 1066,
      "total_cooling_peak_load_btu_h": 17075,
      "calculated_cooling_tonnage": 1.42,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 111.3,
      "sensible_heat_ratio_shr": 0.938,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0464",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 49881,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 56133,
      "summer_conduction_gain_btu_h": 7457,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 809,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 23667,
      "total_cooling_latent_load_btu_h": 1624,
      "total_cooling_peak_load_btu_h": 25291,
      "calculated_cooling_tonnage": 2.11,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 137,
      "sensible_heat_ratio_shr": 0.936,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0465",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 69424,
      "heating_infiltration_loss_btu_h": 9529,
      "total_peak_heating_load_btu_h": 78953,
      "summer_conduction_gain_btu_h": 10291,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 1233,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 32422,
      "total_cooling_latent_load_btu_h": 2256,
      "total_cooling_peak_load_btu_h": 34678,
      "calculated_cooling_tonnage": 2.89,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 149.1,
      "sensible_heat_ratio_shr": 0.935,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0466",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 32510,
      "heating_infiltration_loss_btu_h": 1212,
      "total_peak_heating_load_btu_h": 33722,
      "summer_conduction_gain_btu_h": 4900,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 157,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15709,
      "total_cooling_latent_load_btu_h": 760,
      "total_cooling_peak_load_btu_h": 16469,
      "calculated_cooling_tonnage": 1.37,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 119,
      "sensible_heat_ratio_shr": 0.954,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0467",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 49881,
      "heating_infiltration_loss_btu_h": 2148,
      "total_peak_heating_load_btu_h": 52029,
      "summer_conduction_gain_btu_h": 7457,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 278,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 23136,
      "total_cooling_latent_load_btu_h": 1083,
      "total_cooling_peak_load_btu_h": 24219,
      "calculated_cooling_tonnage": 2.02,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 147.5,
      "sensible_heat_ratio_shr": 0.955,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0468",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 69424,
      "heating_infiltration_loss_btu_h": 3268,
      "total_peak_heating_load_btu_h": 72692,
      "summer_conduction_gain_btu_h": 10291,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 423,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 31612,
      "total_cooling_latent_load_btu_h": 1431,
      "total_cooling_peak_load_btu_h": 33043,
      "calculated_cooling_tonnage": 2.75,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 161.8,
      "sensible_heat_ratio_shr": 0.957,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0469",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 22335,
      "heating_infiltration_loss_btu_h": 8574,
      "total_peak_heating_load_btu_h": 30909,
      "summer_conduction_gain_btu_h": 3583,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1110,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13817,
      "total_cooling_latent_load_btu_h": 1730,
      "total_cooling_peak_load_btu_h": 15547,
      "calculated_cooling_tonnage": 1.3,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 130.8,
      "sensible_heat_ratio_shr": 0.889,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0470",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 34377,
      "heating_infiltration_loss_btu_h": 15184,
      "total_peak_heating_load_btu_h": 49561,
      "summer_conduction_gain_btu_h": 5451,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1965,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 20487,
      "total_cooling_latent_load_btu_h": 2801,
      "total_cooling_peak_load_btu_h": 23288,
      "calculated_cooling_tonnage": 1.94,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 157.7,
      "sensible_heat_ratio_shr": 0.88,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0471",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 47621,
      "heating_infiltration_loss_btu_h": 23152,
      "total_peak_heating_load_btu_h": 70773,
      "summer_conduction_gain_btu_h": 7470,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 2996,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 28088,
      "total_cooling_latent_load_btu_h": 4052,
      "total_cooling_peak_load_btu_h": 32140,
      "calculated_cooling_tonnage": 2.68,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 168.7,
      "sensible_heat_ratio_shr": 0.874,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0472",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 22335,
      "heating_infiltration_loss_btu_h": 3534,
      "total_peak_heating_load_btu_h": 25869,
      "summer_conduction_gain_btu_h": 3583,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 457,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13164,
      "total_cooling_latent_load_btu_h": 1066,
      "total_cooling_peak_load_btu_h": 14230,
      "calculated_cooling_tonnage": 1.19,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 152.1,
      "sensible_heat_ratio_shr": 0.925,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0473",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 34377,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 40629,
      "summer_conduction_gain_btu_h": 5451,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 809,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 19331,
      "total_cooling_latent_load_btu_h": 1624,
      "total_cooling_peak_load_btu_h": 20955,
      "calculated_cooling_tonnage": 1.75,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 185.7,
      "sensible_heat_ratio_shr": 0.923,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0474",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 47621,
      "heating_infiltration_loss_btu_h": 9529,
      "total_peak_heating_load_btu_h": 57150,
      "summer_conduction_gain_btu_h": 7470,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 1233,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 26325,
      "total_cooling_latent_load_btu_h": 2256,
      "total_cooling_peak_load_btu_h": 28581,
      "calculated_cooling_tonnage": 2.38,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 202.5,
      "sensible_heat_ratio_shr": 0.921,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0475",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 22335,
      "heating_infiltration_loss_btu_h": 1212,
      "total_peak_heating_load_btu_h": 23547,
      "summer_conduction_gain_btu_h": 3583,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 157,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 12864,
      "total_cooling_latent_load_btu_h": 760,
      "total_cooling_peak_load_btu_h": 13624,
      "calculated_cooling_tonnage": 1.14,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 163.2,
      "sensible_heat_ratio_shr": 0.944,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0476",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 34377,
      "heating_infiltration_loss_btu_h": 2148,
      "total_peak_heating_load_btu_h": 36525,
      "summer_conduction_gain_btu_h": 5451,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 278,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 18800,
      "total_cooling_latent_load_btu_h": 1083,
      "total_cooling_peak_load_btu_h": 19883,
      "calculated_cooling_tonnage": 1.66,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 201.2,
      "sensible_heat_ratio_shr": 0.946,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0477",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 47621,
      "heating_infiltration_loss_btu_h": 3268,
      "total_peak_heating_load_btu_h": 50889,
      "summer_conduction_gain_btu_h": 7470,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 423,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 25515,
      "total_cooling_latent_load_btu_h": 1431,
      "total_cooling_peak_load_btu_h": 26946,
      "calculated_cooling_tonnage": 2.25,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 220,
      "sensible_heat_ratio_shr": 0.947,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0478",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 18765,
      "heating_infiltration_loss_btu_h": 8574,
      "total_peak_heating_load_btu_h": 27339,
      "summer_conduction_gain_btu_h": 3121,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1110,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9642,
      "total_cooling_latent_load_btu_h": 1730,
      "total_cooling_peak_load_btu_h": 11372,
      "calculated_cooling_tonnage": 0.95,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 215.8,
      "sensible_heat_ratio_shr": 0.848,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0479",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 28937,
      "heating_infiltration_loss_btu_h": 15184,
      "total_peak_heating_load_btu_h": 44121,
      "summer_conduction_gain_btu_h": 4747,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1965,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 14126,
      "total_cooling_latent_load_btu_h": 2801,
      "total_cooling_peak_load_btu_h": 16927,
      "calculated_cooling_tonnage": 1.41,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 254.6,
      "sensible_heat_ratio_shr": 0.835,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0480",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 39971,
      "heating_infiltration_loss_btu_h": 23152,
      "total_peak_heating_load_btu_h": 63123,
      "summer_conduction_gain_btu_h": 6480,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 2996,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 19142,
      "total_cooling_latent_load_btu_h": 4052,
      "total_cooling_peak_load_btu_h": 23194,
      "calculated_cooling_tonnage": 1.93,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 273.1,
      "sensible_heat_ratio_shr": 0.825,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0481",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 18765,
      "heating_infiltration_loss_btu_h": 3534,
      "total_peak_heating_load_btu_h": 22299,
      "summer_conduction_gain_btu_h": 3121,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 457,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 8989,
      "total_cooling_latent_load_btu_h": 1066,
      "total_cooling_peak_load_btu_h": 10055,
      "calculated_cooling_tonnage": 0.84,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 257.1,
      "sensible_heat_ratio_shr": 0.894,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0482",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 28937,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 35189,
      "summer_conduction_gain_btu_h": 4747,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 809,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 12970,
      "total_cooling_latent_load_btu_h": 1624,
      "total_cooling_peak_load_btu_h": 14594,
      "calculated_cooling_tonnage": 1.22,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 309.8,
      "sensible_heat_ratio_shr": 0.889,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0483",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 39971,
      "heating_infiltration_loss_btu_h": 9529,
      "total_peak_heating_load_btu_h": 49500,
      "summer_conduction_gain_btu_h": 6480,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 1233,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 17379,
      "total_cooling_latent_load_btu_h": 2256,
      "total_cooling_peak_load_btu_h": 19635,
      "calculated_cooling_tonnage": 1.64,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 339,
      "sensible_heat_ratio_shr": 0.885,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0484",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 18765,
      "heating_infiltration_loss_btu_h": 1212,
      "total_peak_heating_load_btu_h": 19977,
      "summer_conduction_gain_btu_h": 3121,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 157,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 8689,
      "total_cooling_latent_load_btu_h": 760,
      "total_cooling_peak_load_btu_h": 9449,
      "calculated_cooling_tonnage": 0.79,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 279.7,
      "sensible_heat_ratio_shr": 0.92,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0485",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 28937,
      "heating_infiltration_loss_btu_h": 2148,
      "total_peak_heating_load_btu_h": 31085,
      "summer_conduction_gain_btu_h": 4747,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 278,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 12439,
      "total_cooling_latent_load_btu_h": 1083,
      "total_cooling_peak_load_btu_h": 13522,
      "calculated_cooling_tonnage": 1.13,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 342.5,
      "sensible_heat_ratio_shr": 0.92,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0486",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-19_2x6_16OC_Standard",
      "wall_effective_u_factor": 0.063,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 39971,
      "heating_infiltration_loss_btu_h": 3268,
      "total_peak_heating_load_btu_h": 43239,
      "summer_conduction_gain_btu_h": 6480,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 423,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 16569,
      "total_cooling_latent_load_btu_h": 1431,
      "total_cooling_peak_load_btu_h": 18000,
      "calculated_cooling_tonnage": 1.5,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 380,
      "sensible_heat_ratio_shr": 0.92,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0487",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 31397,
      "heating_infiltration_loss_btu_h": 8574,
      "total_peak_heating_load_btu_h": 39971,
      "summer_conduction_gain_btu_h": 4651,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1110,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16413,
      "total_cooling_latent_load_btu_h": 1730,
      "total_cooling_peak_load_btu_h": 18143,
      "calculated_cooling_tonnage": 1.51,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 98.7,
      "sensible_heat_ratio_shr": 0.905,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0488",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 48311,
      "heating_infiltration_loss_btu_h": 15184,
      "total_peak_heating_load_btu_h": 63495,
      "summer_conduction_gain_btu_h": 7106,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1965,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 24472,
      "total_cooling_latent_load_btu_h": 2801,
      "total_cooling_peak_load_btu_h": 27273,
      "calculated_cooling_tonnage": 2.27,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 120.3,
      "sensible_heat_ratio_shr": 0.897,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0489",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 67414,
      "heating_infiltration_loss_btu_h": 23152,
      "total_peak_heating_load_btu_h": 90566,
      "summer_conduction_gain_btu_h": 9842,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 2996,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 33736,
      "total_cooling_latent_load_btu_h": 4052,
      "total_cooling_peak_load_btu_h": 37788,
      "calculated_cooling_tonnage": 3.15,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 128.6,
      "sensible_heat_ratio_shr": 0.893,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0490",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 31397,
      "heating_infiltration_loss_btu_h": 3534,
      "total_peak_heating_load_btu_h": 34931,
      "summer_conduction_gain_btu_h": 4651,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 457,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15760,
      "total_cooling_latent_load_btu_h": 1066,
      "total_cooling_peak_load_btu_h": 16826,
      "calculated_cooling_tonnage": 1.4,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 114.3,
      "sensible_heat_ratio_shr": 0.937,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0491",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 48311,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 54563,
      "summer_conduction_gain_btu_h": 7106,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 809,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 23316,
      "total_cooling_latent_load_btu_h": 1624,
      "total_cooling_peak_load_btu_h": 24940,
      "calculated_cooling_tonnage": 2.08,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 140.4,
      "sensible_heat_ratio_shr": 0.935,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0492",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 67414,
      "heating_infiltration_loss_btu_h": 9529,
      "total_peak_heating_load_btu_h": 76943,
      "summer_conduction_gain_btu_h": 9842,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 1233,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 31973,
      "total_cooling_latent_load_btu_h": 2256,
      "total_cooling_peak_load_btu_h": 34229,
      "calculated_cooling_tonnage": 2.85,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 152.6,
      "sensible_heat_ratio_shr": 0.934,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0493",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 31397,
      "heating_infiltration_loss_btu_h": 1212,
      "total_peak_heating_load_btu_h": 32609,
      "summer_conduction_gain_btu_h": 4651,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 157,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15460,
      "total_cooling_latent_load_btu_h": 760,
      "total_cooling_peak_load_btu_h": 16220,
      "calculated_cooling_tonnage": 1.35,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 122.2,
      "sensible_heat_ratio_shr": 0.953,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0494",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 48311,
      "heating_infiltration_loss_btu_h": 2148,
      "total_peak_heating_load_btu_h": 50459,
      "summer_conduction_gain_btu_h": 7106,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 278,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 22785,
      "total_cooling_latent_load_btu_h": 1083,
      "total_cooling_peak_load_btu_h": 23868,
      "calculated_cooling_tonnage": 1.99,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 151.3,
      "sensible_heat_ratio_shr": 0.955,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0495",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 67414,
      "heating_infiltration_loss_btu_h": 3268,
      "total_peak_heating_load_btu_h": 70682,
      "summer_conduction_gain_btu_h": 9842,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 423,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 31163,
      "total_cooling_latent_load_btu_h": 1431,
      "total_cooling_peak_load_btu_h": 32594,
      "calculated_cooling_tonnage": 2.72,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 164.7,
      "sensible_heat_ratio_shr": 0.956,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0496",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 21223,
      "heating_infiltration_loss_btu_h": 8574,
      "total_peak_heating_load_btu_h": 29797,
      "summer_conduction_gain_btu_h": 3335,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1110,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13569,
      "total_cooling_latent_load_btu_h": 1730,
      "total_cooling_peak_load_btu_h": 15299,
      "calculated_cooling_tonnage": 1.27,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 136.2,
      "sensible_heat_ratio_shr": 0.887,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0497",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 32807,
      "heating_infiltration_loss_btu_h": 15184,
      "total_peak_heating_load_btu_h": 47991,
      "summer_conduction_gain_btu_h": 5099,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1965,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 20135,
      "total_cooling_latent_load_btu_h": 2801,
      "total_cooling_peak_load_btu_h": 22936,
      "calculated_cooling_tonnage": 1.91,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 161.8,
      "sensible_heat_ratio_shr": 0.878,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0498",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 45611,
      "heating_infiltration_loss_btu_h": 23152,
      "total_peak_heating_load_btu_h": 68763,
      "summer_conduction_gain_btu_h": 7020,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 2996,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 27638,
      "total_cooling_latent_load_btu_h": 4052,
      "total_cooling_peak_load_btu_h": 31690,
      "calculated_cooling_tonnage": 2.64,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 172.7,
      "sensible_heat_ratio_shr": 0.872,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0499",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 21223,
      "heating_infiltration_loss_btu_h": 3534,
      "total_peak_heating_load_btu_h": 24757,
      "summer_conduction_gain_btu_h": 3335,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 457,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 12916,
      "total_cooling_latent_load_btu_h": 1066,
      "total_cooling_peak_load_btu_h": 13982,
      "calculated_cooling_tonnage": 1.17,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 156.4,
      "sensible_heat_ratio_shr": 0.924,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0500",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 32807,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 39059,
      "summer_conduction_gain_btu_h": 5099,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 809,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 18979,
      "total_cooling_latent_load_btu_h": 1624,
      "total_cooling_peak_load_btu_h": 20603,
      "calculated_cooling_tonnage": 1.72,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 190.7,
      "sensible_heat_ratio_shr": 0.921,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0501",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 45611,
      "heating_infiltration_loss_btu_h": 9529,
      "total_peak_heating_load_btu_h": 55140,
      "summer_conduction_gain_btu_h": 7020,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 1233,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 25875,
      "total_cooling_latent_load_btu_h": 2256,
      "total_cooling_peak_load_btu_h": 28131,
      "calculated_cooling_tonnage": 2.34,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 207.7,
      "sensible_heat_ratio_shr": 0.92,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0502",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 21223,
      "heating_infiltration_loss_btu_h": 1212,
      "total_peak_heating_load_btu_h": 22435,
      "summer_conduction_gain_btu_h": 3335,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 157,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 12616,
      "total_cooling_latent_load_btu_h": 760,
      "total_cooling_peak_load_btu_h": 13376,
      "calculated_cooling_tonnage": 1.11,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 170.3,
      "sensible_heat_ratio_shr": 0.943,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0503",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 32807,
      "heating_infiltration_loss_btu_h": 2148,
      "total_peak_heating_load_btu_h": 34955,
      "summer_conduction_gain_btu_h": 5099,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 278,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 18448,
      "total_cooling_latent_load_btu_h": 1083,
      "total_cooling_peak_load_btu_h": 19531,
      "calculated_cooling_tonnage": 1.63,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 206.7,
      "sensible_heat_ratio_shr": 0.945,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0504",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 45611,
      "heating_infiltration_loss_btu_h": 3268,
      "total_peak_heating_load_btu_h": 48879,
      "summer_conduction_gain_btu_h": 7020,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 423,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 25065,
      "total_cooling_latent_load_btu_h": 1431,
      "total_cooling_peak_load_btu_h": 26496,
      "calculated_cooling_tonnage": 2.21,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 225.8,
      "sensible_heat_ratio_shr": 0.946,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0505",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 17653,
      "heating_infiltration_loss_btu_h": 8574,
      "total_peak_heating_load_btu_h": 26227,
      "summer_conduction_gain_btu_h": 2873,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1110,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9394,
      "total_cooling_latent_load_btu_h": 1730,
      "total_cooling_peak_load_btu_h": 11124,
      "calculated_cooling_tonnage": 0.93,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 222.6,
      "sensible_heat_ratio_shr": 0.844,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0506",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 27367,
      "heating_infiltration_loss_btu_h": 15184,
      "total_peak_heating_load_btu_h": 42551,
      "summer_conduction_gain_btu_h": 4395,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1965,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 13774,
      "total_cooling_latent_load_btu_h": 2801,
      "total_cooling_peak_load_btu_h": 16575,
      "calculated_cooling_tonnage": 1.38,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 262.3,
      "sensible_heat_ratio_shr": 0.831,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0507",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 37961,
      "heating_infiltration_loss_btu_h": 23152,
      "total_peak_heating_load_btu_h": 61113,
      "summer_conduction_gain_btu_h": 6030,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 2996,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 18692,
      "total_cooling_latent_load_btu_h": 4052,
      "total_cooling_peak_load_btu_h": 22744,
      "calculated_cooling_tonnage": 1.9,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 278.9,
      "sensible_heat_ratio_shr": 0.822,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0508",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 17653,
      "heating_infiltration_loss_btu_h": 3534,
      "total_peak_heating_load_btu_h": 21187,
      "summer_conduction_gain_btu_h": 2873,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 457,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 8741,
      "total_cooling_latent_load_btu_h": 1066,
      "total_cooling_peak_load_btu_h": 9807,
      "calculated_cooling_tonnage": 0.82,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 265.9,
      "sensible_heat_ratio_shr": 0.891,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0509",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 27367,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 33619,
      "summer_conduction_gain_btu_h": 4395,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 809,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 12618,
      "total_cooling_latent_load_btu_h": 1624,
      "total_cooling_peak_load_btu_h": 14242,
      "calculated_cooling_tonnage": 1.19,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 320.2,
      "sensible_heat_ratio_shr": 0.886,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0510",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 37961,
      "heating_infiltration_loss_btu_h": 9529,
      "total_peak_heating_load_btu_h": 47490,
      "summer_conduction_gain_btu_h": 6030,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 1233,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 16929,
      "total_cooling_latent_load_btu_h": 2256,
      "total_cooling_peak_load_btu_h": 19185,
      "calculated_cooling_tonnage": 1.6,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 350,
      "sensible_heat_ratio_shr": 0.882,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0511",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 17653,
      "heating_infiltration_loss_btu_h": 1212,
      "total_peak_heating_load_btu_h": 18865,
      "summer_conduction_gain_btu_h": 2873,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 157,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 8441,
      "total_cooling_latent_load_btu_h": 760,
      "total_cooling_peak_load_btu_h": 9201,
      "calculated_cooling_tonnage": 0.77,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 289.6,
      "sensible_heat_ratio_shr": 0.917,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0512",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 27367,
      "heating_infiltration_loss_btu_h": 2148,
      "total_peak_heating_load_btu_h": 29515,
      "summer_conduction_gain_btu_h": 4395,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 278,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 12087,
      "total_cooling_latent_load_btu_h": 1083,
      "total_cooling_peak_load_btu_h": 13170,
      "calculated_cooling_tonnage": 1.1,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 354.5,
      "sensible_heat_ratio_shr": 0.918,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0513",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-21_2x6_24OC_Advanced",
      "wall_effective_u_factor": 0.052,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 37961,
      "heating_infiltration_loss_btu_h": 3268,
      "total_peak_heating_load_btu_h": 41229,
      "summer_conduction_gain_btu_h": 6030,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 423,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 16119,
      "total_cooling_latent_load_btu_h": 1431,
      "total_cooling_peak_load_btu_h": 17550,
      "calculated_cooling_tonnage": 1.46,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 393.2,
      "sensible_heat_ratio_shr": 0.918,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0514",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 30184,
      "heating_infiltration_loss_btu_h": 8574,
      "total_peak_heating_load_btu_h": 38758,
      "summer_conduction_gain_btu_h": 4380,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 1110,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 16142,
      "total_cooling_latent_load_btu_h": 1730,
      "total_cooling_peak_load_btu_h": 17872,
      "calculated_cooling_tonnage": 1.49,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 101.3,
      "sensible_heat_ratio_shr": 0.903,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0515",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 46597,
      "heating_infiltration_loss_btu_h": 15184,
      "total_peak_heating_load_btu_h": 61781,
      "summer_conduction_gain_btu_h": 6723,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 1965,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 24089,
      "total_cooling_latent_load_btu_h": 2801,
      "total_cooling_peak_load_btu_h": 26890,
      "calculated_cooling_tonnage": 2.24,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 123.2,
      "sensible_heat_ratio_shr": 0.896,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0516",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 65221,
      "heating_infiltration_loss_btu_h": 23152,
      "total_peak_heating_load_btu_h": 88373,
      "summer_conduction_gain_btu_h": 9352,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 2996,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 33246,
      "total_cooling_latent_load_btu_h": 4052,
      "total_cooling_peak_load_btu_h": 37298,
      "calculated_cooling_tonnage": 3.11,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 131.5,
      "sensible_heat_ratio_shr": 0.891,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0517",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 30184,
      "heating_infiltration_loss_btu_h": 3534,
      "total_peak_heating_load_btu_h": 33718,
      "summer_conduction_gain_btu_h": 4380,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 457,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15489,
      "total_cooling_latent_load_btu_h": 1066,
      "total_cooling_peak_load_btu_h": 16555,
      "calculated_cooling_tonnage": 1.38,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 117.4,
      "sensible_heat_ratio_shr": 0.936,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0518",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 46597,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 52849,
      "summer_conduction_gain_btu_h": 6723,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 809,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 22933,
      "total_cooling_latent_load_btu_h": 1624,
      "total_cooling_peak_load_btu_h": 24557,
      "calculated_cooling_tonnage": 2.05,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 143.9,
      "sensible_heat_ratio_shr": 0.934,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0519",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 65221,
      "heating_infiltration_loss_btu_h": 9529,
      "total_peak_heating_load_btu_h": 74750,
      "summer_conduction_gain_btu_h": 9352,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 1233,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 31483,
      "total_cooling_latent_load_btu_h": 2256,
      "total_cooling_peak_load_btu_h": 33739,
      "calculated_cooling_tonnage": 2.81,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 156.2,
      "sensible_heat_ratio_shr": 0.933,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0520",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 30184,
      "heating_infiltration_loss_btu_h": 1212,
      "total_peak_heating_load_btu_h": 31396,
      "summer_conduction_gain_btu_h": 4380,
      "summer_fenestration_solar_gain_btu_h": 7862,
      "summer_sensible_infiltration_btu_h": 157,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 15189,
      "total_cooling_latent_load_btu_h": 760,
      "total_cooling_peak_load_btu_h": 15949,
      "calculated_cooling_tonnage": 1.33,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 125.6,
      "sensible_heat_ratio_shr": 0.952,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0521",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 46597,
      "heating_infiltration_loss_btu_h": 2148,
      "total_peak_heating_load_btu_h": 48745,
      "summer_conduction_gain_btu_h": 6723,
      "summer_fenestration_solar_gain_btu_h": 11981,
      "summer_sensible_infiltration_btu_h": 278,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 22402,
      "total_cooling_latent_load_btu_h": 1083,
      "total_cooling_peak_load_btu_h": 23485,
      "calculated_cooling_tonnage": 1.96,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 155.1,
      "sensible_heat_ratio_shr": 0.954,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0522",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Single_Clear_Aluminum",
      "fenestration_u_factor": 1.05,
      "fenestration_shgc": 0.72,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 65221,
      "heating_infiltration_loss_btu_h": 3268,
      "total_peak_heating_load_btu_h": 68489,
      "summer_conduction_gain_btu_h": 9352,
      "summer_fenestration_solar_gain_btu_h": 16848,
      "summer_sensible_infiltration_btu_h": 423,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 30673,
      "total_cooling_latent_load_btu_h": 1431,
      "total_cooling_peak_load_btu_h": 32104,
      "calculated_cooling_tonnage": 2.68,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 168.7,
      "sensible_heat_ratio_shr": 0.955,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0523",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 20009,
      "heating_infiltration_loss_btu_h": 8574,
      "total_peak_heating_load_btu_h": 28583,
      "summer_conduction_gain_btu_h": 3063,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 1110,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 13297,
      "total_cooling_latent_load_btu_h": 1730,
      "total_cooling_peak_load_btu_h": 15027,
      "calculated_cooling_tonnage": 1.25,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 140,
      "sensible_heat_ratio_shr": 0.885,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0524",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 31093,
      "heating_infiltration_loss_btu_h": 15184,
      "total_peak_heating_load_btu_h": 46277,
      "summer_conduction_gain_btu_h": 4716,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 1965,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 19752,
      "total_cooling_latent_load_btu_h": 2801,
      "total_cooling_peak_load_btu_h": 22553,
      "calculated_cooling_tonnage": 1.88,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 166,
      "sensible_heat_ratio_shr": 0.876,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0525",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 43418,
      "heating_infiltration_loss_btu_h": 23152,
      "total_peak_heating_load_btu_h": 66570,
      "summer_conduction_gain_btu_h": 6530,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 2996,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 27148,
      "total_cooling_latent_load_btu_h": 4052,
      "total_cooling_peak_load_btu_h": 31200,
      "calculated_cooling_tonnage": 2.6,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 176.9,
      "sensible_heat_ratio_shr": 0.87,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0526",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 20009,
      "heating_infiltration_loss_btu_h": 3534,
      "total_peak_heating_load_btu_h": 23543,
      "summer_conduction_gain_btu_h": 3063,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 457,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 12644,
      "total_cooling_latent_load_btu_h": 1066,
      "total_cooling_peak_load_btu_h": 13710,
      "calculated_cooling_tonnage": 1.14,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 163.2,
      "sensible_heat_ratio_shr": 0.922,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0527",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 31093,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 37345,
      "summer_conduction_gain_btu_h": 4716,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 809,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 18596,
      "total_cooling_latent_load_btu_h": 1624,
      "total_cooling_peak_load_btu_h": 20220,
      "calculated_cooling_tonnage": 1.69,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 195.9,
      "sensible_heat_ratio_shr": 0.92,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0528",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 43418,
      "heating_infiltration_loss_btu_h": 9529,
      "total_peak_heating_load_btu_h": 52947,
      "summer_conduction_gain_btu_h": 6530,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 1233,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 25385,
      "total_cooling_latent_load_btu_h": 2256,
      "total_cooling_peak_load_btu_h": 27641,
      "calculated_cooling_tonnage": 2.3,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 213,
      "sensible_heat_ratio_shr": 0.918,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0529",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 20009,
      "heating_infiltration_loss_btu_h": 1212,
      "total_peak_heating_load_btu_h": 21221,
      "summer_conduction_gain_btu_h": 3063,
      "summer_fenestration_solar_gain_btu_h": 6334,
      "summer_sensible_infiltration_btu_h": 157,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 12344,
      "total_cooling_latent_load_btu_h": 760,
      "total_cooling_peak_load_btu_h": 13104,
      "calculated_cooling_tonnage": 1.09,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 175.2,
      "sensible_heat_ratio_shr": 0.942,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0530",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 31093,
      "heating_infiltration_loss_btu_h": 2148,
      "total_peak_heating_load_btu_h": 33241,
      "summer_conduction_gain_btu_h": 4716,
      "summer_fenestration_solar_gain_btu_h": 9651,
      "summer_sensible_infiltration_btu_h": 278,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 18065,
      "total_cooling_latent_load_btu_h": 1083,
      "total_cooling_peak_load_btu_h": 19148,
      "calculated_cooling_tonnage": 1.6,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 212.5,
      "sensible_heat_ratio_shr": 0.943,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0531",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_Clear_Metal",
      "fenestration_u_factor": 0.48,
      "fenestration_shgc": 0.58,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 43418,
      "heating_infiltration_loss_btu_h": 3268,
      "total_peak_heating_load_btu_h": 46686,
      "summer_conduction_gain_btu_h": 6530,
      "summer_fenestration_solar_gain_btu_h": 13572,
      "summer_sensible_infiltration_btu_h": 423,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 24575,
      "total_cooling_latent_load_btu_h": 1431,
      "total_cooling_peak_load_btu_h": 26006,
      "calculated_cooling_tonnage": 2.17,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 231.8,
      "sensible_heat_ratio_shr": 0.945,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0532",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 93.4,
      "heating_conduction_loss_btu_h": 16439,
      "heating_infiltration_loss_btu_h": 8574,
      "total_peak_heating_load_btu_h": 25013,
      "summer_conduction_gain_btu_h": 2601,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 1110,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 9122,
      "total_cooling_latent_load_btu_h": 1730,
      "total_cooling_peak_load_btu_h": 10852,
      "calculated_cooling_tonnage": 0.9,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 233.3,
      "sensible_heat_ratio_shr": 0.841,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0533",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 165.4,
      "heating_conduction_loss_btu_h": 25653,
      "heating_infiltration_loss_btu_h": 15184,
      "total_peak_heating_load_btu_h": 40837,
      "summer_conduction_gain_btu_h": 4012,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 1965,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 13391,
      "total_cooling_latent_load_btu_h": 2801,
      "total_cooling_peak_load_btu_h": 16192,
      "calculated_cooling_tonnage": 1.35,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 270.4,
      "sensible_heat_ratio_shr": 0.827,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0534",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 8.5,
      "infiltration_design_cfm": 252.2,
      "heating_conduction_loss_btu_h": 35768,
      "heating_infiltration_loss_btu_h": 23152,
      "total_peak_heating_load_btu_h": 58920,
      "summer_conduction_gain_btu_h": 5540,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 2996,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 18202,
      "total_cooling_latent_load_btu_h": 4052,
      "total_cooling_peak_load_btu_h": 22254,
      "calculated_cooling_tonnage": 1.85,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 289.2,
      "sensible_heat_ratio_shr": 0.818,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0535",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 38.5,
      "heating_conduction_loss_btu_h": 16439,
      "heating_infiltration_loss_btu_h": 3534,
      "total_peak_heating_load_btu_h": 19973,
      "summer_conduction_gain_btu_h": 2601,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 457,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 8469,
      "total_cooling_latent_load_btu_h": 1066,
      "total_cooling_peak_load_btu_h": 9535,
      "calculated_cooling_tonnage": 0.79,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 279.7,
      "sensible_heat_ratio_shr": 0.888,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0536",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 68.1,
      "heating_conduction_loss_btu_h": 25653,
      "heating_infiltration_loss_btu_h": 6252,
      "total_peak_heating_load_btu_h": 31905,
      "summer_conduction_gain_btu_h": 4012,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 809,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 12235,
      "total_cooling_latent_load_btu_h": 1624,
      "total_cooling_peak_load_btu_h": 13859,
      "calculated_cooling_tonnage": 1.15,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 334.8,
      "sensible_heat_ratio_shr": 0.883,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0537",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 3.5,
      "infiltration_design_cfm": 103.8,
      "heating_conduction_loss_btu_h": 35768,
      "heating_infiltration_loss_btu_h": 9529,
      "total_peak_heating_load_btu_h": 45297,
      "summer_conduction_gain_btu_h": 5540,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 1233,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 16439,
      "total_cooling_latent_load_btu_h": 2256,
      "total_cooling_peak_load_btu_h": 18695,
      "calculated_cooling_tonnage": 1.56,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 361.5,
      "sensible_heat_ratio_shr": 0.879,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0538",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 1500,
      "dwelling_volume_cuft": 12000,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 13.2,
      "heating_conduction_loss_btu_h": 16439,
      "heating_infiltration_loss_btu_h": 1212,
      "total_peak_heating_load_btu_h": 17651,
      "summer_conduction_gain_btu_h": 2601,
      "summer_fenestration_solar_gain_btu_h": 2621,
      "summer_sensible_infiltration_btu_h": 157,
      "summer_internal_sensible_gain_btu_h": 2790,
      "total_cooling_sensible_load_btu_h": 8169,
      "total_cooling_latent_load_btu_h": 760,
      "total_cooling_peak_load_btu_h": 8929,
      "calculated_cooling_tonnage": 0.74,
      "rule_of_thumb_tonnage_500sqft": 3,
      "heuristic_oversize_percentage": 305.4,
      "sensible_heat_ratio_shr": 0.915,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0539",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 2500,
      "dwelling_volume_cuft": 21250,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 23.4,
      "heating_conduction_loss_btu_h": 25653,
      "heating_infiltration_loss_btu_h": 2148,
      "total_peak_heating_load_btu_h": 27801,
      "summer_conduction_gain_btu_h": 4012,
      "summer_fenestration_solar_gain_btu_h": 3994,
      "summer_sensible_infiltration_btu_h": 278,
      "summer_internal_sensible_gain_btu_h": 3420,
      "total_cooling_sensible_load_btu_h": 11704,
      "total_cooling_latent_load_btu_h": 1083,
      "total_cooling_peak_load_btu_h": 12787,
      "calculated_cooling_tonnage": 1.07,
      "rule_of_thumb_tonnage_500sqft": 5,
      "heuristic_oversize_percentage": 367.3,
      "sensible_heat_ratio_shr": 0.915,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    },
    {
      "scenario_id": "ENV-0540",
      "climate_zone": "CZ-6",
      "climate_zone_name": "Very Cold (Minneapolis/Helena)",
      "outdoor_winter_db_f": -15,
      "outdoor_summer_db_f": 86,
      "outdoor_summer_wb_f": 70,
      "indoor_winter_setpoint_f": 70,
      "indoor_summer_setpoint_f": 75,
      "floor_area_sqft": 3600,
      "dwelling_volume_cuft": 32400,
      "wall_assembly_id": "R-20+5ci_HighPerformance",
      "wall_effective_u_factor": 0.04,
      "fenestration_id": "Double_LowE_Argon_Vinyl",
      "fenestration_u_factor": 0.28,
      "fenestration_shgc": 0.24,
      "infiltration_ach50": 1.2,
      "infiltration_design_cfm": 35.6,
      "heating_conduction_loss_btu_h": 35768,
      "heating_infiltration_loss_btu_h": 3268,
      "total_peak_heating_load_btu_h": 39036,
      "summer_conduction_gain_btu_h": 5540,
      "summer_fenestration_solar_gain_btu_h": 5616,
      "summer_sensible_infiltration_btu_h": 423,
      "summer_internal_sensible_gain_btu_h": 4050,
      "total_cooling_sensible_load_btu_h": 15629,
      "total_cooling_latent_load_btu_h": 1431,
      "total_cooling_peak_load_btu_h": 17060,
      "calculated_cooling_tonnage": 1.42,
      "rule_of_thumb_tonnage_500sqft": 7.2,
      "heuristic_oversize_percentage": 407,
      "sensible_heat_ratio_shr": 0.916,
      "canonical_reference_url": "https://hvaclogic.org/calculators/btu-calculator"
    }
  ]
}