Building Science

Building Heat Loss & Infiltration Calculator

Estimate whole-building peak heat loss combining envelope conductive transmission (U * A * Delta T), slab perimeter F-factors, and air infiltration leakage.

Interactive Calculator & Visualizer

Representative Building Vintages:
Client-Side Math โ€ข No Sign-Up or Database Required โ€ข Instant Local Execution
๐Ÿ“ASHRAE Climatic Design Conditions50 States + CA
View Full Climatic Database โ†’
Winter 99%
-2ยฐF
Summer 0.4%
90ยฐF
Coincident WB
74ยฐF
IECC Zone
5A
Wall Conduction ModelThermal Bridging Tool โ†—
Preliminary Peak Building Heat Loss
25,428 BTU/hr
Power Demand: 7.5 kW โ€ข ฮ”T = 60ยฐF (70ยฐF in / 10ยฐF out)
12.7 BTU/sq ftยทhr Specific Thermal Intensity
๐Ÿ  ๐Ÿ”ฅEnvelope & Infiltration Heat Flux
12.7 BTU/ftยฒยทhr Intensity
Foundation Perimeter (21%) โ€ข 5,367 BTU/hrCeiling & Attic (12%) โ€ข 3,077 BTU/hr20%20%Door (840 BTU)Air Leakage (114 CFM)Infiltration: 29% (7,387 BTU)Walls (15%)
Preliminary Peak Load: 25,428 BTU/hr (7.5 kW)Estimated Infiltration: 114 CFM (0.38 ACHnat)
Air Infiltration Loss
7,387 BTU/hr (29%)
Envelope Conduction
18,041 BTU/hr (71%)
Estimated Infiltration Airflow
114 CFM (0.38 ACHnat)
Foundation / Slab Conduction
5,367 BTU/hr (F-0.5)

Engineering Methodology & Governing Equations

โš™๏ธ

Hydronic & Forced-Air Thermal Generation Flow

Fuel combustion and reverse-cycle heat pumping to offset building thermal envelope transmission losses.

๐Ÿ”ฅHeat InputThermal InputBurner / Heat Pump
๐Ÿ›ก๏ธTransferHeat Exchanger80%โ€“98% AFUE rating
๐ŸŒ€CirculationBlower DeliveryDelta-T rise (35ยฐFโ€“65ยฐF)
๐Ÿ ComfortConditioned ZoneEnvelope loss offset
๐Ÿ’ก Engineering Note: Heat pump Coefficient of Performance (COP) decreases as outdoor ambient temperatures drop; balance point calculations dictate auxiliary strip heat engagement.

Whole-Building Peak Heat Loss & Infiltration Equations

governing_physics_model.math
ASHRAE / ACCA SPEC
01Q_conductive = sum(U_i * A_i * Delta T) + (F_slab * P * Delta T)
02Q_infiltration = 1.08 * CFM_inf * Delta T
03Q_total = Q_conductive + Q_infiltration
SymbolVariableDescriptionStandard Units
Q_totalPeak Building Heat LossPreliminary heating power required to maintain indoor temperature under winter design conditionsBTU/hr
U_iAssembly U-FactorOverall thermal transmittance of building envelope surface (1 / R_effective)BTU/hrยทftยฒยทยฐF
A_iSurface AreaNet surface area of above-grade walls, ceiling/roof, windows, and exterior doorssq ft
F_slabFoundation F-FactorLinear heat loss coefficient per linear foot of exposed slab perimeter (e.g. F-0.50 for uninsulated slab)BTU/hrยทftยทยฐF
Delta TDesign Temperature DifferenceIndoor setpoint minus the local 99% ASHRAE winter design outdoor temperatureยฐF
CFM_infInfiltration AirflowNatural outdoor air leakage volume entering through envelope cracks (Volume * ACHnat / 60)CFM

๐Ÿ’ก Engineering Note: This tool calculates a preliminary whole-building screening estimate. Air leakage is governed by the sensible heat equation with standard air constant 1.08. For detailed room-by-room heating loads, execute a complete ACCA Manual J calculation.

๐Ÿ›๏ธEngineering Standard Reference: ASHRAE Handbook of Fundamentals & ACCA Manual J (8th Edition)

Conductive Transmission, Foundation F-Factors & Infiltration

A home loses heat through three primary physical pathways:

  • Envelope Conduction (Q = U ร— A ร— ฮ”T): Heat transferring through solid above-grade walls, roof/ceiling, windows, and exterior doors. To account for framing thermal bridging across wood or steel studs, evaluate assembly U-factors with the Effective R-Value Calculator.
  • Foundation Perimeter Conduction (Q = F ร— P ร— ฮ”T): Slab-on-grade heat loss occurs predominantly at the exposed slab edge perimeter rather than uniformly through the slab floor. ACCA Manual J and ASHRAE characterize slab loss using linear F-factors (e.g., F-0.50 for uninsulated edge slabs).
  • Air Infiltration Leakage (Q = 1.08 ร— CFM ร— ฮ”T): Cold outdoor air entering through unsealed envelope penetrations. Natural air changes per hour (ACHnat) are derived from blower-door tightness tiers (ACH50 / N-factor) multiplied by building volume.

Screening Estimates vs. ACCA Manual J & Manual S Sizing

This calculator provides a preliminary building-level heat loss estimate based on simplified geometric baselines. It is not a substitute for a full room-by-room ACCA Manual J load calculation, which accounts for exact window orientations, duct heat losses, internal heat gains, and room boundary surfaces. Furthermore, equipment selection requires applying ACCA Manual S sizing limits against manufacturer-verified heating output tables at local design temperatures.

Standard Engineering Reference Matrix

Building Envelope Vintage2,000 Sq Ft Peak Heat LossThermal IntensityInfiltration SharePreliminary Demand
2020s High-Efficiency Tight Home15,950 BTU/hr (4.7 kW)8.0 BTU/sq ftยทhr16%16.0 kBTU/hr Load Reference
1990s Standard Code Suburban30,120 BTU/hr (8.8 kW)15.1 BTU/sq ftยทhr25%30.1 kBTU/hr Load Reference
1960s Semi-Insulated Ranch46,840 BTU/hr (13.7 kW)23.4 BTU/sq ftยทhr32%46.8 kBTU/hr Load Reference
Pre-1940 Historic Leaky (Uninsulated)72,650 BTU/hr (21.3 kW)36.3 BTU/sq ftยทhr44%72.7 kBTU/hr Load Reference

Worked Engineering Sizing Example

Scenario: Calculating preliminary peak heat loss for a 2,000 sq ft home in Denver, CO where 99% winter outdoor design temperature is 10.0ยฐF and indoor heating setpoint is 70.0ยฐF (ฮ”T = 60.0ยฐF).

Calculation Steps:

  1. Design Temperature Difference: ฮ”T = 70.0 - 10.0 = 60.0ยฐF.
  2. Building Dimensions: Perimeter P = 4 ร— โˆš2000 = 178.9 ft. Gross wall area = 178.9 ร— 9 ft = 1,610 sq ft. Glazing (15%) = 300 sq ft. Doors = 40 sq ft. Net wall area = 1,270 sq ft. Volume = 18,000 cu ft.
  3. Above-Grade Wall Conduction: 1,270 sq ft net wall @ nominal R-19 (estimated layer R-20.5, U-0.04878) ร— 60.0ยฐF = 3,717 BTU/hr.
  4. Ceiling & Attic Conduction: 2,000 sq ft ceiling @ nominal R-38 (estimated layer R-39.0, U-0.02564) ร— 60.0ยฐF = 3,077 BTU/hr.
  5. Window Conduction: 300 sq ft Low-E glass @ U-0.28 ร— 60.0ยฐF = 5,040 BTU/hr.
  6. Exterior Doors Conduction: 40 sq ft insulated doors @ U-0.35 ร— 60.0ยฐF = 840 BTU/hr.
  7. Slab Perimeter Conduction: 178.9 ft perimeter @ F-0.50 ร— 60.0ยฐF = 5,367 BTU/hr.
  8. Air Infiltration Leakage: 18,000 cu ft volume @ 0.38 ACHnat = 114 CFM. Infiltration loss = 1.08 ร— 114 CFM ร— 60.0ยฐF = 7,387 BTU/hr.
  9. Total Preliminary Peak Heat Loss: 3,717 + 3,077 + 5,040 + 840 + 5,367 + 7,387 = 25,428 BTU/hr (7.5 kW).
  10. Equipment Sizing Note: This preliminary building load (25.4 kBTU/hr) represents the baseline screening rate. Equipment selection requires full room-by-room ACCA Manual J load calculations and manufacturer-verified heating output tables per ACCA Manual S.

Frequently Asked Questions

How is conductive envelope heat loss calculated?
Conductive heat loss is calculated using Fourier's heat transfer equation: Q = U * A * Delta T, where U is the surface assembly U-factor (1 / R_effective), A is net surface area in square feet, and Delta T is the difference between indoor setpoint and outdoor 99% design temperature.
How does air infiltration affect building heat loss?
Air infiltration heat loss is calculated using the sensible air equation: Q = 1.08 * CFM * Delta T. Airflow entering through envelope leakage is derived from building volume and natural air changes per hour (ACHnat = ACH50 / N-factor).
What is the difference between preliminary heat loss and ACCA Manual J load calculation?
This calculator provides a preliminary whole-building screening estimate based on simplified geometric baselines. A formal ACCA Manual J calculation evaluates room-by-room boundary areas, directional solar heat gains, internal loads, and duct transmission to size equipment per ACCA Manual S.
How is slab-on-grade foundation heat loss modeled?
Slab foundation heat loss occurs primarily through the exposed slab edge perimeter. Per ASHRAE Fundamentals and ACCA Manual J Table 4A, slab loss is modeled as Q = F * Perimeter * Delta T, where F is the linear edge heat-loss factor (e.g., F-0.50 BTU/hrยทftยทยฐF for uninsulated slab edges).
๐Ÿ“šScientific Methodology & Academic Courseware

Governing Research Monograph: Deterministic Building Science & Dynamic Enclosure Infiltration Modeling for Residential Space Heating and Decarbonization Sizing

Report: HL-TR-2026-ENV03 โ€ข Authors: HVACLogic Research Group, Miad S.