๐Airflow & Ductsโฑ๏ธ 12 min readLIVE
Comprehensive fluid mechanics reference for sizing HVAC supply and return ductwork, evaluating Colebrook-White friction rates, Huebscher equivalent diameters, and ACCA Manual D available static pressure workflows.
Key Equation:
ฮpf = 100 ร f ร (12 / Dh) ร (ฯ ร vยฒ / (2 ร gc))
ASHRAE Fundamentals Ch. 21ACCA Manual DSMACNA HVAC Duct Design
Read Master Guide โโ๏ธCooling Loadsโฑ๏ธ 14 min readLIVE
Methodology for calculating peak residential sensible and latent cooling loads, evaluating Sensible Heat Ratios (SHR), and selecting equipment matching expanded manufacturer performance tables.
Key Equation:
Q_sensible = U ร A ร (T_outdoor - T_indoor) + CLTD
ACCA Manual J (8th Edition)ACCA Manual SASHRAE Standard 55
Read Master Guide โ๐ฅHeating & Heat Pumpsโฑ๏ธ 15 min readLIVE
Engineering principles of residential heating, cold-climate air-source heat pump COP derating curves, auxiliary strip staging, hydronic condensing boiler dew points, and NFPA 54 combustion air sizing.
Key Equation:
Q_heat_loss = ฮฃ(U ร A ร ฮT) + (1.08 ร CFM_infiltration ร ฮT)
AHRI Standard 210/240ASHRAE Standard 90.1NFPA 54 / IFGCNEEP ccASHP v4.0
Read Master Guide โ๐งDiagnostics & PTโฑ๏ธ 13 min readLIVE
A complete technician and engineering manual for EPA 608 Section 608 compliance, managing non-linear zeotropic temperature glide in R-454B and R-32, target superheat/subcooling charging, and line-set weigh-in adjustments.
Key Equation:
Subcooling = T_bubble(P_liquid) - T_liquid_line
EPA Clean Air Act Sec. 608NIST REFPROP 10.0AHRI Standard 210/240ASHRAE Standard 34
Read Master Guide โ๐ขBuilding Scienceโฑ๏ธ 14 min readLIVE
Fundamental thermodynamics of moist air, ASHRAE Hyland-Wexler formulations, parallel-path R-value thermal bridging, and LBNL Sherman-Grimsrud blower door infiltration modeling.
Key Equation:
ln(p_ws) = C1/T + C2 + C3*T + C4*Tยฒ + C5*Tยณ + C6*ln(T)
ASHRAE Handbook of Fundamentals Ch. 1ASHRAE Standard 90.1IECC 2021/2024ASTM E779
Read Master Guide โ๐Building Scienceโฑ๏ธ 13 min readLIVE
Comprehensive engineering reference for calculating whole-wall assembly U-factors, parallel-path heat transfer through wood studs, and ASHRAE 90.1 Appendix A effective cavity insulation deratings for cold-formed steel framing.
Key Equation:
U_wood = (f_framing / R_framing_path) + (f_cavity / R_cavity_path)
ANSI/ASHRAE/IES Standard 90.1-2022ASHRAE HandbookโFundamentals Ch. 25/27IECC 2024 / 2021 Table C402.1.4
Read Master Guide โโ๏ธDiagnostics & PTโฑ๏ธ 14 min readLIVE
Definitive thermodynamic and safety guide for transitioning to next-generation A2L refrigerants (R-454B, R-32). Details ASHRAE 15-2024 charge calculations (m1, m2, m3), UL 60335-2-40 detection requirements, and zeotropic temperature glide charging protocols.
Key Equation:
m1 = 0.20 ร LFL ร V_eff
ANSI/ASHRAE Standard 15-2024ANSI/ASHRAE Standard 34-2022UL 60335-2-40 (4th Edition)EPA AIM Act 40 CFR Part 84
Read Master Guide โ