📊 CSV Benchmark Dataset240 Verified RecordsđŸ›Ąī¸ CC BY 4.0 InternationalDOI: 10.6084/m9.figshare.33477430 ↗

Cold-Climate Heat Pump COP Derating & Heating Load Balance Point Dataset

Empirical and thermodynamic performance matrix modeling variable-speed inverter air-source heat pumps. The dataset evaluates compressor capacity retention, Coefficient of Performance (COP) degradation, latent defrost penalties, building heating balance points, and auxiliary electric resistance strip staging requirements.

đŸ“ĨDownload CSV (23.5 KB)📊View on Figshare Data Repository ↗

đŸ”Ŧ Dataset Methodology & Engineering Basis

Simulations model residential heating loads per ACCA Manual J and heat pump capacity curves conforming to AHRI 210/240 and NEEP cold-climate specifications. Defrost degradation is modeled below 40°F with dynamic frost accumulation curves and timed reverse-cycle penalties.

Governing Engineering Standards & Codes:

đŸ›ī¸ ACCA Manual S (Residential Equipment Selection)đŸ›ī¸ AHRI Standard 210/240-2023 (Performance Rating of Heat Pumps)đŸ›ī¸ NEEP Cold Climate Air Source Heat Pump Specification (Version 4.0)

📋 Tabular Data Preview (First 5 Rows)

Displaying 5 of 240 rows
Record_IDOutdoor_Temp_degFIndoor_Temp_degFNominal_TonnageOperating_COPEffective_Heating_Cap_Btu_hrBuilding_Heat_Demand_Btu_hrAux_Electric_Heat_kWBalance_Point_Status
HL-HP-0001-157021.410800272004.81below_balance_point
HL-HP-0002-107021.6312360256003.88below_balance_point
HL-HP-0003-57021.8513920240002.95below_balance_point
HL-HP-000407022.0715480224002.03below_balance_point
HL-HP-000557022.317040208001.1below_balance_point

📖 Data Dictionary & Variable Definitions

Complete schema definition describing each column, engineering unit of measure, data type, and thermodynamic description:

Variable NameData TypeUnitEngineering Description
Record_IDstring—Unique simulation vector identifier (HL-HP-0001 to HL-HP-0240)
Outdoor_Temp_degFnumber°FOutdoor ambient dry-bulb temperature (-15.0°F to 50.0°F)
Indoor_Temp_degFnumber°FConditioned space indoor design setpoint (70.0°F)
Design_Heat_Loss_Btu_hrnumberBTU/hBuilding envelope peak design heating load
Nominal_TonnagenumberTonsHeat pump nominal equipment frame (2.0 to 5.0 Tons)
Rated_Heating_Cap_47F_BtunumberBTU/hRated heating capacity at AHRI 47°F rating point
Compressor_Speedstring—Inverter operating state (min, intermediate, max)
Operating_COPnumberratioInstantaneous thermodynamic Coefficient of Performance
Gross_Heating_Cap_Btu_hrnumberBTU/hUncorrected compressor thermal output before defrost derate
Defrost_Derate_FactornumberfractionLatent frost accumulation penalty factor (0.82 to 1.00)
Effective_Heating_Cap_Btu_hrnumberBTU/hNet deliverable heating power to building envelope
Building_Heat_Demand_Btu_hrnumberBTU/hEnvelope thermal loss demand at current ambient temperature
Thermal_Deficit_Btu_hrnumberBTU/hUnmet heating demand below thermal balance point
Aux_Electric_Heat_kWnumberkWElectric resistance backup heat required to maintain indoor temperature
Balance_Point_Statusstring—Regime classification (above_balance_point, below_balance_point)

🧮 Interactive Companion Calculators

Test and explore these mathematical models dynamically in our client-side calculators:

Heat Pump Size & Balance Point Calculator →

Calculate thermal balance point, low-ambient COP derating, and backup heat staging.

🎓 Companion Research Whitepapers

Read the full mathematical derivations and thermodynamic proofs:

Interactive Engineering Lab: Cold-Climate Heat Pump Balance Points →

Thermodynamic modeling of cold-climate inverter derating, balance points, and auxiliary loads.

📚 Academic Citation & Replication

When referencing this benchmark dataset in academic publications, university course syllabi, or engineering technical reports, please cite as follows:

HVACLogic Open Engineering Research Group. (2026). Cold-Climate Heat Pump COP Derating & Heating Load Balance Point Dataset [Data set]. HVACLogic Open Science. https://doi.org/10.6084/m9.figshare.33477430

BibTeX Entry:

@dataset{hvaclogic_cold_climate_heat_pump_cop_derating,
  author = {{HVACLogic Open Engineering Research Group}},
  title = {Cold-Climate Heat Pump COP Derating & Heating Load Balance Point Dataset},
  year = {2026},
  publisher = {HVACLogic Open Science},
  url = {https://hvaclogic.org/datasets/cold-climate-heat-pump-cop-derating},
  doi = {10.6084/m9.figshare.33477430}
}