Effective Outdoor Air Dilution, Continuous Infiltration Credit, and Multi-Zone Mass-Balance Modeling under ASHRAE 62.2
A mass-balance analysis of residential mechanical ventilation rates, dwelling volume air changes, and continuous versus intermittent exhaust fan duty cycles.
Abstract
Key Technical Findings & Code Impacts
- In tight modern enclosures ($<3.0\text{ ACH}_{50}$), mechanical ventilation must deliver at least $45\text{ to }75\text{ CFM}$ of continuous fresh outdoor air to maintain steady-state indoor $\text{CO}_2$ concentrations below $1,000\text{ PPM}$.
- Energy Recovery Ventilators (ERVs) with sensible recovery effectiveness $\ge 72\%$ reduce winter ventilation thermal conditioning penalties by up to $65\%$ while managing indoor winter relative humidity.
- Intermittent mechanical ventilation strategies operating at fractional duty cycles ($<100\%$) require non-linear airflow rate multipliers ($ge 1.33\times$) under ASHRAE 62.2 Section 4.5 to maintain equivalent air exchange effectiveness.
- Combustion air makeup requirements for non-direct vent fossil-fuel appliances must be decoupled from general dilution ventilation to prevent hazardous backdrafting under negative building depressurization.
Governing Industry Standards & Codes
Mathematical Formulations & Governing Equations
ASHRAE 62.2 Total Ventilation Rate Equation
đĄ Governing standard equation defining minimum continuous volumetric outdoor airflow based on conditioned floor area and default occupant density.
Continuous Mechanical Fan Sizing with Infiltration Credit
đĄ Determines net required mechanical ventilation fan rate after applying natural infiltration credits derived from blower door envelope leakage tests.
Steady-State Indoor CO2 Dilution Mass-Balance
đĄ Predicts indoor steady-state contaminant concentration from outdoor ambient baseline, occupant generation rate, and effective outdoor air exchange rate.
Companion Calculation Engines & Simulation Models
CFM Airflow & Duct Velocity Calculator
Calculate air changes per hour (ACH), velocity in FPM, and required room CFM.
Combustion Air Ventilation Calculator
Size indoor and outdoor combustion air openings per NFPA 54 / IFGC.
Kitchen Exhaust Hood CFM Calculator
Size range hood exhaust and makeup air requirements.
Academic Citations & BibTeX
To cite this technical report in university coursework, dissertations, or engineering research:
APA Format:
HVACLogic Research Group, & S., M. (2026). Effective Outdoor Air Dilution, Continuous Infiltration Credit, and Multi-Zone Mass-Balance Modeling under ASHRAE 62.2 (Technical Report No. HL-TR-2026-IAQ04). HVACLogic Open-Access Building Science. https://doi.org/10.6084/m9.figshare.172310811
BibTeX Entry:
@techreport{hvaclogic_2026_iaq_ventilation,
author = {{HVACLogic Research Group} and S., Miad},
title = {Effective Outdoor Air Dilution, Continuous Infiltration Credit, and Multi-Zone Mass-Balance Modeling under ASHRAE 62.2},
institution = {HVACLogic Open-Access Building Science Monograph Series},
year = {2026},
number = {HL-TR-2026-IAQ04},
doi = {10.6084/m9.figshare.172310811},
url = {https://hvaclogic.com/research/effective-dilution-iaq-ventilation-mass-balance}
}